29 July 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
The correlation between the decomposition products and discharge faults in the electrical equipment with the environmentally friendly insulating gas mixture C 4 F 7 N/CO 2 /O 2 remains inadequately revealed. and the corresponding characterization methods also need to be determined. In this paper, a feature fusion algorithm based on the stacking-attention mechanism is proposed. The ratios of decomposition products from C 4 F 7 N/CO 2 /O 2 mixtures in various proportions under different discharge conditions are utilized as the dataset. Multiple feature extraction algorithms are employed as base learners to derive feature subsets from diverse dimensions. Subsequently, these feature subsets are fused using the attention mechanism as the meta-learner, and the contribution of each feature value is determined, thereby identifying the optimal feature subset. Experimental results demonstrate that the optimal feature values extracted by this method, when applied to classification algorithms such as Support Vector Machines (SVM) and Artificial Neural Networks (ANN), effectively distinguish between defects including corona discharge, spark discharge, and suspended discharge in environmentally friendly gas-insulated equipment. Based on the decomposition characteristics, the ratios of CO/(C 3 F 6 +CF 4 ) and CF 4 /C 3 F 8 are proposed as diagnostic indicators for identifying discharge faults in engineering applications of C 4 F 7 N/CO 2 /O 2 gas-insulated equipment. The research results of this paper provide both theoretical and technical support for the operation and maintenance of gas-insulated electrical equipment.
19 June 2026 in Journal of Physics D: Applied Physics
In high-voltage pulse energy storage systems, coupled electrical-thermal stress from high-repetition-rate pulses during initial discharge induces self-healing effects in capacitors that may ultimately trigger insulation failure. In this work, self-healing characteristics of metallized biaxially oriented polypropylene (BOPP) film under high-repetition-rate pulsed voltage based on the actual capacitor electrode structure was investigated, while concurrently elucidating their mechanism through electro-thermal coupling analysis. The results indicate that below 6 kHz repetition-rate, the electrode region exhibits the most pronounced degradation, with metal layer ablation forming interconnected dendritic patterns. In contrast, above 20 kHz frequency, the electrode damage area remains nearly invariant as frequency increases, and the self-healing points are predominantly isolated, exhibiting high circularity and low fractal dimension. Simultaneously, Fourier Transform Infra-Red (FTIR) scanning results of carbonization reaction induced by Joule heating above 20 kHz further confirm that the self-healing mechanism is governed by a repetition-rate dependent transition from metal layer ablation to localized dielectric breakdown. Bridging the voltage thermal coupling and self-healing characteristics, this work provides understanding of failure mechanism of dielectric film under high dv/dt and high-repetition-rate pulsed voltage.
21 September 2026 in Applied Physics Letters
Metallized film capacitors have become key energy storage components in new energy power systems, electric vehicles, and pulsed power equipment due to their high power density and self-healing capability. However, the demand for higher power density and miniaturization poses challenges to their reliability. Moreover, research on single-layer metallized film self-healing may overlook interlayer failure mechanisms and cascading effects. We report a cross-layer failure induced by accumulated self-healing damage in multilayer metallized films. After applying 1.8 times the rated voltage for 5 h, the short-circuit failed core was dissected layer-by-layer and reconstructed by micro-CT. The short circuit originated from a multilayer through-cavity extending across metallized film layers, surrounded by dense self-healing zones. Inner-layer cavities pierced more layers but stayed compact; outer-layer cavities pierced fewer layers but spread wider. Further analysis suggests that interlayer cavities and connected demetallized regions formed by accumulated self-healing may weaken the restriction on discharge expansion and hinder the local pressure buildup required for rapid arc extinction, thereby prolonging the arcing duration. Continuous heat input induces interlayer cascade breakdown through thermal activation effects, ultimately melting the multilayer dielectric and metal electrodes. This study reveals that three-dimensional cumulative damage is the key triggering condition for the transition from progressive degradation to sudden short circuit, which provides a reference for design optimization and performance improvement of metallized film capacitors.
1 January 2026 in IEEE Transactions on Dielectrics and Electrical Insulation
10 March 2026 in IEEE Transactions on Dielectrics and Electrical Insulation
Self-healing performance constitutes a critical determinant for ensuring reliability of metallized film capacitors (MFCs). By utilizing capacitor component to investigate the internal self-healing distribution and mechanisms under actual operating conditions (3.92 kV DC and 70°C) enable the location of faults and evade inaccuracy of multi-physics decoupling during film-level experiment. In this work, self-healing distribution was investigated, while concurrently elucidating the mechanism combined with microstructure analysis. The results indicate that within the two internally series-connected capacitances, the upper capacitance demonstrates 126.9% max higher quantity and 38.1% max larger area of self-healing, with this asymmetric distribution exhibiting strong spatial correlation with metallized film location. The Scanning Electron Microscope (SEM) and Energy Dispersive X-ray (EDX) spectroscopy results indicate that self-healing points in inner layer area exhibit high circularity and low fractal dimension, along with a decrease in Zn elemental content. The increased internal pressure (8-16 MPa) is the primary cause of reduced self-healing by inhibiting plasma expansion and increasing the energy threshold, while the pressure-induced 2.1% increase in film crystallinity acts as a secondary factor that contributes to altered self-healing distribution. This work elucidates the self-healing distribution mechanisms within MFC and offers critical guidance for the structural optimization and reliability design of MFCs.
26 January 2026 in IEEE Transactions on Plasma Science
Metallized polypropylene film capacitors (MPPFCs) are an important structure in superconducting magnetic energy storage (SMES) systems. This article systematically investigates the correlation mechanisms between self-healing parameters in metallized polypropylene films (MPPFs) under different environmental conditions. Results show that elevated temperature at $65~^{\circ }$ C enhances plasma activity, increasing self-healing energy to 6.5 mJ, three times higher than $25~^{\circ }$ C, while thermal expansion mismatch between metallized layer and polypropylene layer at $85~^{\circ }$ C induces activity in self-healing process. Pressure, however, reduces the self-healing energy from 0.2 to 10 MPa and changes the situation of the polypropylene layer’s surface, causing damage to the hydrophobic property in the polypropylene layer. The data of arc initiation time and arc extinction time in the self-healing waveform exhibit a two-stage development, representing two stages of the self-healing process under different conditions. Finally, a self-healing simulation model was developed and validated against experimental data, successfully replicating the non monotonic trend in the self-healing area, which is an initial increase followed by a reduction with rising temperature.