1 November 2019 in Radiology
One-view digital breast tomosynthesis screening depicts more of the same types of cancers compared with digital mammography and does not alter the molecular subtype distribution of screen-detected ... Background Screening accuracy can be improved with digital breast tomosynthesis (DBT). To further evaluate DBT in screening, it is important to assess the molecular subtypes of the detected cancers...
23 March 2002 in European Radiology
17 May 2005 in Radiation Protection Dosimetry
The Sectra MicroDose Mammography system is based on direct photon counting (with a solid-state detector), and a substantially lower dose to the breast than when using conventional systems can be expected. In this work absorbed dose measurements have been performed for the first unit used in routine mammography screening (at the Hospital of Helsingborg, Sweden). Two European protocols on dosimetry in mammography have been followed. Measurement of half value layer (HVL) cannot be performed as prescribed, but this study has demonstrated that non-invasive measurements of HVL can be performed accurately with a sensitive and well collimated solid-state detector with simultaneous correction for the energy dependence. The average glandular dose for a 50 mm standard breast with 50% glandularity, simulated by 45 mm polymethylmethacrylate, was found to be 0.21 and 0.28 mGy in March and December 2004, respectively. These values are much lower than for any other mammography system on the market today. It has to be stressed that the measurements were made using the current clinical settings and that no systematic optimisation of the relationship between absorbed dose and diagnostic image quality has been performed within the present study. In order to further increase the accuracy of absorbed dose measurements for this unit, the existing dose protocols should be revised to account also for the tungsten/aluminium anode/filter combination, the multi-slit pre-collimator device and the occurrence of a dose profile in the scanning direction.
17 May 2005 in Radiation Protection Dosimetry
In this study a set of structures has been simulated to represent a range of clinically relevant breast cancer mammographic lesions including solid tumours and microcalcifications. All structures have been created using simple random-based mathematical functions and have been inserted into a subset of digital mammography images at appropriate contrast levels into various regions of the breast, including dense fibroglandular and adipose tissue. These structures and their appearance in these clinical images were evaluated in terms of how realistic they looked. They will be used as the input to a large-scale clinical trial designed to examine the effect of significant dose reduction in digital mammography by comparing the detectability of such structures in images acquired at full and quarter automatic exposure control (AEC) dose level and in images with simulated noise levels in between.
1 November 2021 in Radiology: Artificial Intelligence
A digital mammography (DM) artificial intelligence (AI) system was evaluated as a stand-alone reader, using digital breast tomosynthesis with double reading as ground truth; additional cancers were... Purpose To investigate how an artificial intelligence (AI) system performs at digital mammography (DM) from a screening population with ground truth defined by digital breast tomosynthesis (DBT), a...