Patrick Neis

Patrick Neis

Auto-generated profile, based on publicly available information

Patrick Neis

Forschungszentrum Jülich GmbH, Institut für Energie and Klimaforschung, IEK-8 Troposphäre, 52425 Jülich, Germany

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2017 in Faraday Discussions
Verified
Journal Article
Closed access
PDF file
APAndreas Petzold
Andreas Petzold
MKMartina Krämer
Martina Krämer
PNPatrick Neis
Patrick Neis
CRChristian Rolf
Christian Rolf
SRSusanne Rohs
Susanne Rohs
AWAndreas Wahner
Andreas Wahner
IAGOS (In-service Aircraft for a Global Observing System) performs long-term routine in situ observations of atmospheric chemical composition (O 3 , CO, NO x , NO y , CO 2 , CH 4 ), water vapour, aerosols, clouds, and temperature on a global scale by operating compact instruments on board of passenger aircraft. The unique characteristics of the IAGOS data set originate from the global scale sampling on air traffic routes with similar instrumentation such that the observations are truly comparable and well suited for atmospheric research on a statistical basis. Here, we present the analysis of 15 months of simultaneous observations of relative humidity with respect to ice (RH ice ) and ice crystal number concentration in cirrus ( N ice ) from July 2014 to October 2015. The joint data set of 360 hours of RH ice – N ice observations in the global upper troposphere and tropopause region is analysed with respect to the in-cloud distribution of RH ice and related cirrus properties. The majority of the observed cirrus is thin with N ice < 0.1 cm −3 . The respective fractions of all cloud observations range from 90% over the mid-latitude North Atlantic Ocean and the Eurasian Continent to 67% over the subtropical and tropical Pacific Ocean. The in-cloud RH ice distributions do not depend on the geographical region of sampling. Types of cirrus origin ( in situ origin, liquid origin) are inferred for different N ice regimes and geographical regions. Most importantly, we found that in-cloud RH ice shows a strong correlation to N ice with slightly supersaturated dynamic equilibrium RH ice associated with higher N ice values in stronger updrafts.

1 January 2015 in Tellus B: Chemical and Physical Meteorology
Verified
Journal Article
Open access
PDF file
PNPatrick Neis
Patrick Neis
HSHerman G. J. Smit
Herman G. J. Smit
SRSusanne Rohs
Susanne Rohs
UBUlrich Bundke
Ulrich Bundke
MKMartina Krämer
Martina Krämer
APAndreas Petzold
Andreas Petzold
Quality assessment of MOZAIC and IAGOS capacitive hygrometers: insights from airborne field studies

11 December 2014 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
HSH. G. J. Smit
H. G. J. Smit
SRSusanne Rohs
Susanne Rohs
PNP. Neis
P. Neis
DBD. Boulanger
D. Boulanger
MKMartina Krämer
Martina Krämer
APA. Petzold
A. Petzold
In situ observational data on the relative humidity (RH) in the upper troposphere and lowermost stratosphere (UT/LS), or tropopause region, collected aboard civil passenger aircraft in the MOZAIC (Measurements of OZone, water vapour, carbon monoxide and nitrogen oxides by in-service AIrbus airCraft) programme were reanalysed for the period 2000 to 2009. Previous analyses of probability distribution functions (PDFs) of upper troposphere humidity (UTH) data from MOZAIC observations from year 2000 and later indicated a bias of UTH data towards higher RH values compared to data of the period 1994 to 1999. As a result, the PDF of UTH data show a substantial fraction of observations above 100% relative humidity with respect to liquid water. Such supersaturations, however, do not occur in the atmosphere because there is always a sufficient number of condensation nuclei available, that trigger condensation as soon as liquid saturation is slightly exceeded. An in-depth reanalysis of the data set identified a coding error in the calibration procedure from year 2000 on. The error did not affect earlier data from 1994 to 1999. The full data set for 2000–2009 was reanalysed applying the corrected calibration procedure. Applied correction schemes and a revised error analysis are presented along with the reanalysed PDF of relative humidity with respect to liquid water (RHliquid) and ice (RHice).

13 March 2015 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
PNP. Neis
P. Neis
HSH. G. J. Smit
H. G. J. Smit
MKMartina Krämer
Martina Krämer
NSN. Spelten
N. Spelten
APA. Petzold
A. Petzold
The MOZAIC Capacitive Hygrometer (MCH) is usually operated aboard passenger aircraft in the framework of MOZAIC (Measurement of Ozone by Airbus In-Service Aircraft) for measuring atmospheric relative humidity (RH). In order to evaluate the performance of the MCH, the instrument was operated aboard a Learjet 35A research aircraft as part of the CIRRUS-III field study together with a closed-cell Lyman-α fluorescence hygrometer (Fast in situ Stratospheric Hygrometer, or FISH) and an open-path tunable diode laser system (Open-path Jülich Stratospheric TDL ExpeRiment, or OJSTER) for water vapour measurement. After reducing the CIRRUS-III data set to data corresponding to MOZAIC aircraft operation conditions, the 1 Hz RH data cross correlation between the MCH and reference instruments FISH (clear sky) and OJSTER (in-cirrus) yielded a remarkably good agreement of R2 = 0.92 and slope m = 1.02 and provided a MCH uncertainty of 5% RH. Probability distribution functions of RH deduced from the MCH and reference instruments agreed well between 10 and 70% RH with respect to liquid water in the ambient temperature range of ca. −70 to −40 °C. The use of MCH data is limited to sensor temperatures above the calibration limit of Tsensor = −40 °C (corresponds to ambient temperature of Tambient = −70 °C at typical cruising speed of long-haul passenger aircraft). Good performance of the MCH for clear sky as well as for in-cirrus conditions demonstrated the sensor robustness also for operation inside ice clouds.

29 July 2014 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
PRP. Reutter
P. Reutter
JTJ. Trentmann
J. Trentmann
ASAxel Seifert
Axel Seifert
PNP. Neis
P. Neis
HSH. Su
H. Su
UPU. Pöschl
U. Pöschl
Dynamical and microphysical processes in pyroconvective clouds in mid-latitude conditions are investigated using idealized three-dimensional simulations with the Active Tracer High resolution Atmospheric Model (ATHAM). A state-of-the-art two-moment microphysical scheme building upon a realistic parameterization of cloud condensation nuclei (CCN) activation has been implemented in order to study the influence of aerosol concentration on cloud development. The results show that aerosol concentration influences the formation of precipitation. For low aerosol concentrations (NCN = 200 cm−3), rain droplets are rapidly formed by autoconversion of cloud droplets. This also triggers the formation of large graupel and hail particles, resulting in an early onset of precipitation. With increasing aerosol concentration (NCN = 1000 cm−3 and NCN = 20 000 cm−3) the formation of rain droplets is delayed due to more but smaller cloud droplets. Therefore, the formation of ice crystals and snowflakes becomes more important for the eventual formation of graupel and hail, which is delayed at higher aerosol concentrations. This results in a delay of the onset of precipitation and a reduction of its intensity with increasing aerosol concentration. This study is the first detailed investigation of the interaction between cloud microphysics and the dynamics of a pyroconvective cloud using the combination of a high-resolution atmospheric model and a detailed microphysical scheme.

1 January 2015 in Tellus B: Chemical and Physical Meteorology
Verified
Journal Article
Open access
PDF file
HCHannah Clark
Hannah Clark
BSBastien Sauvage
Bastien Sauvage
VTValérie Thouret
Valérie Thouret
PNPhilippe Nédélec
Philippe Nédélec
RBRomain Blot
Romain Blot
JCJean-Pierre Cammas
Jean-Pierre Cammas
The first regular measurements of ozone, carbon monoxide and water vapour in the Pacific UTLS by IAGOS