Hunkyu Seo

Hunkyu Seo

Auto-generated profile, based on publicly available information

Hunkyu Seo

Department of Materials Science and Engineering, Yonsei University College of Engineering, Seoul 03722, Republic of Korea

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
WPWonjung Park
Wonjung Park
HSHunkyu Seo
Hunkyu Seo
JKJeongho Kim
Jeongho Kim
YHYeon-Mi Hong
Yeon-Mi Hong
HSHayoung Song
Hayoung Song
Jang-Ung ParkJang-Ung Park
Jang-Ung Park
Tears have emerged as a promising alternative to blood for diagnosing diabetes. Despite increasing attempts to measure tear glucose using smart contact lenses, the controversy surrounding the correlation between tear glucose and blood glucose still limits the clinical usage of tears. Herein, we present an in-depth investigation of the correlation between tear glucose and blood glucose using a wireless and soft smart contact lens for continuous monitoring of tear glucose. This smart contact lens is capable of quantitatively monitoring the tear glucose levels in basal tears excluding the effect of reflex tears which might weaken the relationship with blood glucose. Furthermore, this smart contact lens can provide an unprecedented level of continuous tear glucose data acquisition at sub-minute intervals. These advantages allow the precise estimation of lag time, enabling the establishment of the concept called ‘personalized lag time’. This demonstration considers individual differences and is successfully applied to both non-diabetic and diabetic humans, as well as in animal models, resulting in a high correlation.

25 September 2023 in Chemical Reviews
Verified
Journal Article
Open access
HSHunkyu Seo
Hunkyu Seo
WCWon Gi Chung
Won Gi Chung
YKYong Won Kwon
Yong Won Kwon
SKSumin Kim
Sumin Kim
YHYeon-Mi Hong
Yeon-Mi Hong
Jang-Ung ParkJang-Ung Park
Jang-Ung Park
The eye contains a complex network of physiological information and biomarkers for monitoring disease and managing health, and ocular devices can be used to effectively perform point-of-care diagnosis and disease management. This comprehensive review describes the target biomarkers and various diseases, including ophthalmic diseases, metabolic diseases, and neurological diseases, based on the physiological and anatomical background of the eye. This review also includes the recent technologies utilized in eye-wearable medical devices and the latest trends in wearable ophthalmic devices, specifically smart contact lenses for the purpose of disease management. After introducing other ocular devices such as the retinal prosthesis, we further discuss the current challenges and potential possibilities of smart contact lenses.

11 April 2024 in Communications Materials
Verified
Journal Article
Open access
PDF file
KLKyeonghee Lim
Kyeonghee Lim
HSHunkyu Seo
Hunkyu Seo
WCWon Gi Chung
Won Gi Chung
HSHayoung Song
Hayoung Song
MOMyoungjae Oh
Myoungjae Oh
Jang-Ung ParkJang-Ung Park
Jang-Ung Park
Wearable skin-contacting devices are extensively studied for their ability to provide convenient and safe health monitoring. A key aspect that controls their performance are the properties of the device electrodes. Optimizing electrode structure, and the materials they are made from, can improve device functionality. Here, we discuss the various properties required for optimal electrode performance, including mechanical, electrical, and biocompatible factors. To address these challenges, we consider alteration of electrode structure, the development of flexible or soft conductive materials, and the creation of hybrid structures. Additionally, the integration of artificial intelligence is proposed as a promising direction to achieve smart devices. As well as outlining essential characteristics for high-performance wearable skin devices we also offer insight into possible future applications.

15 January 2024 in Nature Nanotechnology
Verified
Journal Article
Open access
PDF file
WCWon Gi Chung
Won Gi Chung
JJJiuk Jang
Jiuk Jang
GCGang Cui
Gang Cui
SLSanghoon Lee
Sanghoon Lee
HJHan Jeong
Han Jeong
Jang-Ung ParkJang-Ung Park
Jang-Ung Park
Electronic retinal prostheses for stimulating retinal neurons are promising for vision restoration. However, the rigid electrodes of conventional retinal implants can inflict damage on the soft retina tissue. They also have limited selectivity due to their poor proximity to target cells in the degenerative retina. Here we present a soft artificial retina (thickness, 10 μm) where flexible ultrathin photosensitive transistors are integrated with three-dimensional stimulation electrodes of eutectic gallium–indium alloy. Platinum nanoclusters locally coated only on the tip of these three-dimensional liquid-metal electrodes show advantages in reducing the impedance of the stimulation electrodes. These microelectrodes can enhance the proximity to the target retinal ganglion cells and provide effective charge injections (72.84 mC cm−2) to elicit neural responses in the retina. Their low Young’s modulus (234 kPa), owing to their liquid form, can minimize damage to the retina. Furthermore, we used an unsupervised machine learning approach to effectively identify the evoked spikes to grade neural activities within the retinal ganglion cells. Results from in vivo experiments on a retinal degeneration mouse model reveal that the spatiotemporal distribution of neural responses on their retina can be mapped under selective localized illumination areas of light, suggesting the restoration of their vision.

16 September 2022 in Science Advances
Verified
Journal Article
Open access
JHJae Chul Hwang
Jae Chul Hwang
MKMoohyun Kim
Moohyun Kim
SKSumin Kim
Sumin Kim
HSHunkyu Seo
Hunkyu Seo
SASoohwan An
Soohwan An
Jang-Ung ParkJang-Ung Park
Jang-Ung Park
The in situ diagnosis of cardiac activities with simultaneous therapeutic electrical stimulation of the heart is key to preventing cardiac arrhythmia. Here, we present an unconventional single-device platform that enables in situ monitoring even in a wet condition and control of beating heart motions without interferences to the recording signal. This platform consists of the active-matrix array of pressure-sensitive transistors for detecting cardiac beatings, biocompatible, low-impedance electrodes for cardiac stimulations, and an alginate-based hydrogel adhesive for attaching this platform conformally to the epicardium. In contrast to conventional electrophysiological sensing using electrodes, the pressure-sensitive transistors measured mechanophysiological characteristics by monitoring the spatiotemporal distributions of cardiac pressures during heart beating motions. In vivo tests show mechanophysiological readings having good correlation with electrocardiography and negligible interference with the electrical artifacts caused during cardiac stimulations. This platform can therapeutically synchronize the rhythm of abnormal heartbeats through efficient pacing of cardiac arrhythmia.

9 February 2024 in Science Advances
Verified
Journal Article
Open access
HSHunkyu Seo
Hunkyu Seo
YHYeon-Mi Hong
Yeon-Mi Hong
WCWon Gi Chung
Won Gi Chung
WPWonjung Park
Wonjung Park
JLJakyoung Lee
Jakyoung Lee
Jang-Ung ParkJang-Ung Park
Jang-Ung Park
Glaucoma causes irreversible vision loss due to optic nerve damage and retinal cell degeneration. Since high intraocular pressure (IOP) is a major risk factor for glaucoma development, accurate IOP measurement is crucial, especially intravitreal IOP affecting the optical nerve and cells. However, conventional methods have limits in selectively and directly detecting local retina pressure. Here, we present continuous measurements of local IOP values in the anterior chamber and vitreous chamber of living animals using minimally invasive probes with pressure-sensitive transistors. After inducing glaucoma in animal models, we compared the local IOP distribution between normal and glaucomatous eyes. We also compared IOP values detected in the cornea using tonometry measurements. Our findings revealed that glaucoma induced higher IOP in the vitreous chamber than in the anterior chamber, indicating that measuring IOP in the vitreous chamber is key to the glaucoma model. This progress offers future directions for diagnosis and treatment of glaucoma.