Mehmet Araç

Mehmet Araç

Auto-generated profile, based on publicly available information

Mehmet Araç

Department of Radiology, Gazi University, Faculty of Medicine, Ankara, Turkey

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2004 in European Radiology
Verified
Journal Article
Closed access
PDF file
MAMehmet Arac
Mehmet Arac
HCHalil Celik
Halil Celik
AOAli Yusuf Oner
Ali Yusuf Oner
SGSerap Gultekin
Serap Gultekin
TGTerman Gumus
Terman Gumus
SKSule Kosar
Sule Kosar

18 June 2004 in International Journal of Dermatology
Verified
Journal Article
Closed access
PDF file
FYFikriye Yılmaz
Fikriye Yılmaz
MAMehmet Araç
Mehmet Araç
MÇM. Akif Çiftçioglu
M. Akif Çiftçioglu
EYErtan Yilmaz
Ertan Yilmaz

1 October 2003 in Radiology
Verified
Journal Article
Closed access
MAMehmet Arac
Mehmet Arac
AOA. Yusuf Oner
A. Yusuf Oner
HCHalil Celik
Halil Celik
SASergin Akpek
Sergin Akpek
SISedat Isik
Sedat Isik
To evaluate multiple-segment reconstruction to reduce cardiac-motion artifacts on thin-section computed tomographic (CT) images in the lung. Fifty patients were enrolled in the study. All images were obtained with a scanner capable of 1-second revolution time. Routine lung thin-section CT examination was performed with images reconstructed with bone algorithm. Multiple-segment images reconstructed with lung algorithm were obtained for three levels in the left paracardiac region. Segment images were reconstructed retrospectively with data for 225 degrees rotation rather than the 360 degrees rotation used for a complete scan. To minimize differences resulting from reconstruction algorithms, additional nonsegmented reconstruction was performed with lung algorithm. Three radiologists reviewed each set of images and assigned a quality score. Multiway analysis of variance was performed to compare motion artifact reduction with 225 degrees and 360 degrees reconstructions. Differences were not significant (P >.05) between scores for images reconstructed with bone or lung algorithms. Differences were significant between scores for reconstructed images obtained with the combination of 360 degrees bone and 225 degrees segment algorithms (P <.001) and for those obtained with the combination of 360 degrees lung and 225 degrees segment algorithms (P <.001). Multiple-segment reconstruction of lung thin-section CT images is an effective technique for reducing cardiac-motion artifacts without increasing patient dose.

1 December 1995 in European Journal of Radiology
Verified
Journal Article
Closed access
BÖBaran Önal
Baran Önal
HÖHakan Özdemir
Hakan Özdemir
MAMehmet Araç
Mehmet Araç
IÖIzlem Öznur
Izlem Öznur
SISedat Işik
Sedat Işik

30 October 2024 in Intercontinental Journal of Internal Medicine
Verified
Journal Article
Open access
PDF file
HÇHasibe Gökçe Çınar
Hasibe Gökçe Çınar
EIErhan Turgut Ilgıt
Erhan Turgut Ilgıt
MAMehmet Araç
Mehmet Araç
Aims: With the development of spiral scanning, computed tomography angiography (CTA) is preferred over conventional angiography in many vascular applications. Reduced respiratory and motion artifacts and ability to catch arterial phase during one inspiration are the advantages of spiral CTA. Our aim in this study is to evaluate the value of spiral CTA in demonstrating stent integrity, stent patency, and renal artery/stent relationship after renal artery stenting. Methods: 15 patients (12 male and 3 female) who had renal artery metallic stents were included in this study. Systolic and diastolic blood pressure and creatinine values of the patients were measured before and after the stent. Patients were examined by CTA after renal artery stenting. In renal artery segments with renal artery stenosis and stenting on CTA; stent diameter, stent length, integrity, luminal contrast enhancement and intraluminal calcification were evaluated with 1 mm axial reconstructed images and "post-process" techniques multiplanar reformat (MPR), maximum intensity projection (MIP), shaded surface display (SSD), and virtual intravascular endoscopy (VIE). Results: Of the stenosis in which stents were placed, 1 was located in the proximal renal artery, 4 were in the mid-renal artery, and 10 were ostial. The whole stent was visualized in 8 cases. Among the MPR images, the axial plane was the best to depict the lumen in 13 cases. The stent lumen was best visualized on oblique MPR images in the axial plane. The visibility of the stent lumen decreased in MIP images with increased slice thickness. In cases where stenosis was considered due to intimal hyperplasia within the stent, no stenotic appearance was observed on MPR and MIP images. In all patients, stent and wall calcifications were observed separately from the contrast medium on MPR and MIP images. On SSD images, the stent could not be distinguished from contrast material and vascular wall calcifications in all patients. In VIE images, the renal artery ostium and the stent were viewed from the aortic lumen in all patients. The stent was observed as patent in 14 cases. In one case, occlusion was demonstrated proximal to the stent. Conclusion: Spiral CTA is a noninvasive procedure in evaluating the integrity of the stent, stent patency and renal artery/stent relationship after renal artery stenting.

3 July 2023 in The European Research Journal
Verified
Journal Article
Open access
PDF file
AAAydan Avdan Aslan
Aydan Avdan Aslan
GEGonca Erbaş
Gonca Erbaş
LMLeyla Salimli Mirzayeva
Leyla Salimli Mirzayeva
KKKoray Kılıç
Koray Kılıç
MAMehmet Araç
Mehmet Araç
Objectives: To compare high-pitch spiral (HPS) and prospectively-gated step-and-shoot (SAS) coronary CT angiography (CCTA) using third generation dual-source CT regarding objective and subjective image quality parameters and radiation exposure. Methods: Eighty pairs of patients matched for gender, age, heart rate and BMI were enrolled in this retrospective study. High-pitch spiral and prospectively ECG-gated sequential CCTA were performed using third generation dual-source CT. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the left ventricle were calculated for each group. Image quality were also scored using four-point scale. Student t-test was used to compare SNR, CNR and mean effective dose values (ED) and Wilcoxon test was used to compare image quality scores. Interrater aggreement were evaluated using Cohen’s kappa statistics. Results: Between-group differences in terms of age, gender, BMI, heart rate, and Agatston score were statistically not significant. Mean SNR and CNR was higher in prospective SAS protocol (16.5 ± 6.2 vs. 14.7 ± 4.9, p = 0.047 and 13.0 ± 5.2 vs. 11.2 ± 4.3, p = 0.02). Image quality scores showed no significant difference between two scan protocols (p > 0.05). Regarding radiation exposure, CT dose index (CTDIvol), dose length product (DLP) and ED was significantly lower for high-pitch group (p < 0.0001). Conclusions: HPS CCTA using DSCT enables > 70% dose reduction while maintaining the image quality compared to prospectively ECG-gated SAS protocol. Therefore, HPS CCTA protocol can be preferred in patients appropriate for prospective ECG-triggered protocol.