Mike Brookes

Mike Brookes

Auto-generated profile, based on publicly available information

Mike Brookes

Department of Electrical and Electronic Engineering, Imperial College London, London, United Kingdom

Research Focus & Metrics

Academic Career Length

46Years (1981-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2023 in IEEE Open Journal of Signal Processing
Verified
Journal Article
Open access
EGEric Grinstein
Eric Grinstein
CHChristopher M. Hicks
Christopher M. Hicks
TWToon van Waterschoot
Toon van Waterschoot
MBMike Brookes
Mike Brookes
PNPatrick A. Naylor
Patrick A. Naylor
Neural networks have achieved state-of-the-art performance on the task of acoustic Direction-of-Arrival (DOA) estimation using microphone arrays. Neural models can be classified as end-to-end or hybrid, each class showing advantages and disadvantages. This work introduces Neural-SRP, an end-to-end neural network architecture for DOA estimation inspired by the classical Steered Response Power (SRP) method, which overcomes limitations of current neural models. We evaluate the architecture on multiple scenarios, namely, multi-source DOA tracking and single-source DOA tracking under the presence of directional and diffuse noise. The experiments demonstrate that our proposed method compares favourably in terms of computational and localization performance with established neural methods on various recorded and simulated benchmark datasets.

25 December 2017 in IEEE/ACM Transactions on Audio, Speech, and Language Processing
Verified
Journal Article
Open access
YWYu Wang
Yu Wang
MBMike Brookes
Mike Brookes
This paper presents an algorithm for modulationdomain speech enhancement using a Kalman filter. The proposed estimator jointly models the estimated dynamics of the spectral amplitudes of speech and noise to obtain an MMSE estimation of the speech amplitude spectrum with the assumption that the speech and noise are additive in the complex domain. In order to include the dynamics of noise amplitudes with those of speech amplitudes, we propose a statistical “Gaussring” model that comprises a mixture of Gaussians whose centres lie in a circle on the complex plane. The performance of the proposed algorithm is evaluated using the perceptual evaluation of speech quality (PESQ) measure, segmental SNR (segSNR) measure and shorttime objective intelligibility (STOI) measure. For speech quality measures, the proposed algorithm is shown to give a consistent improvement over a wide range of SNRs when compared to competitive algorithms. Speech recognition experiments also show that the Gaussring model based algorithm performs well for two types of noise.

7 June 2022 in IEEE/ACM Transactions on Audio, Speech, and Language Processing
Verified
Journal Article
Open access
AMAlastair H. Moore
Alastair H. Moore
SHSina Hafezi
Sina Hafezi
RVRebecca R. Vos
Rebecca R. Vos
PNPatrick A. Naylor
Patrick A. Naylor
MBMike Brookes
Mike Brookes
Acoustic beamforming is routinely used to improve the SNR of the received signal in applications such as hearing aids, robot audition, augmented reality, teleconferencing, source localisation and source tracking. The beamformer can be made adaptive by using an estimate of the time-varying noise covariance matrix in the spectral domain to determine an optimised beam pattern in each frequency bin that is specific to the acoustic environment and that can respond to temporal changes in it. However, robust estimation of the noise covariance matrix remains a challenging task especially in non-stationary acoustic environments. This paper presents a compact model of the signal covariance matrix that is defined by a small number of parameters whose values can be reliably estimated. The model leads to a robust estimate of the noise covariance matrix which can, in turn, be used to construct a beamformer. The performance of beamformers designed using this approach is evaluated for a spherical microphone array under a range of conditions using both simulated and measured room impulse responses. The proposed approach demonstrates consistent gains in intelligibility and perceptual quality metrics compared to the static and adaptive beamformers used as baselines.

1 May 2019 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
PDF file
AMAlastair H. Moore
Alastair H. Moore
JHJan Mark de Haan
Jan Mark de Haan
MPMichael Syskind Pedersen
Michael Syskind Pedersen
PNPatrick A. Naylor
Patrick A. Naylor
MBMike Brookes
Mike Brookes
JJJesper Jensen
Jesper Jensen
The effect of personalized microphone array calibration on the performance of hearing aid beamformers under noisy reverberant conditions is studied. The study makes use of a new, publicly available, database containing acoustic transfer function measurements from 29 loudspeakers arranged on a sphere to a pair of behind-the-ear hearing aids in a listening room when worn by 27 males, 14 females, and 4 mannequins. Bilateral and binaural beamformers are designed using each participant's hearing aid head-related impulse responses (HAHRIRs). The performance of these personalized beamformers is compared to that of mismatched beamformers, where the HAHRIR used for the design does not belong to the individual for whom performance is measured. The case where the mismatched HAHRIR is that of a mannequin is of particular interest since it represents current practice in commercially available hearing aids. The benefit of personalized beamforming is assessed using an intrusive binaural speech intelligibility metric and in a matrix speech intelligibility test. For binaural beamforming, both measures demonstrate a statistically signficant (p < 0.05) benefit of personalization. The benefit varies substantially between individuals with some predicted to benefit by as much as 1.5 dB.

31 January 2018 in IEEE/ACM Transactions on Audio, Speech, and Language Processing
Verified
Journal Article
Open access
NDNikolaos Dionelis
Nikolaos Dionelis
MBMike Brookes
Mike Brookes
We present a speech enhancement algorithm that performs modulation-domain Kalman filtering to track the speech phase using circular statistics, along with the log-spectra of speech and noise. In the proposed algorithm, the speech phase posterior is used to create an enhanced speech phase spectrum for the signal reconstruction of speech. The Kalman filter prediction step separately models the temporal inter-frame correlation of the speech and noise spectral log-amplitudes and of the speech phase, while the Kalman filter update step models their nonlinear relations under the assumption that speech and noise add in the complex short-time Fourier transform domain. The phase-sensitive enhancement algorithm is evaluated with speech quality and intelligibility metrics, using a variety of noise types over a range of SNRs. Instrumental measures predict that tracking the speech log-spectrum and phase with modulation-domain Kalman filtering leads to consistent improvements in speech quality, over both conventional enhancement algorithms and other algorithms that perform modulation-domain Kalman filtering.

1 April 2017 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
CDClement S. J. Doire
Clement S. J. Doire
MBMike Brookes
Mike Brookes
PNPatrick A. Naylor
Patrick A. Naylor
The efficient measurement of the threshold and slope of the psychometric function (PF) is an important objective in psychoacoustics. This paper proposes a procedure that combines a Bayesian estimate of the PF with either a look one-ahead or a look two-ahead method of selecting the next stimulus presentation. The procedure differs from previously proposed algorithms in two respects: (i) it does not require the range of possible PF parameters to be specified in advance and (ii) the sequence of probe signal-to-noise ratios optimizes the threshold and slope estimates at a performance level, ϕ, that can be chosen by the experimenter. Simulation results show that the proposed procedure is robust and that the estimates of both threshold and slope have a consistently low bias. Over a wide range of listener PF parameters, the root-mean-square errors after 50 trials were ∼1.2 dB in threshold and 0.14 in log-slope. It was found that the performance differences between the look one-ahead and look two-ahead methods were negligible and that an entropy-based criterion for selecting the next stimulus was preferred to a variance-based criterion.