David Rode

David Rode

Auto-generated profile, based on publicly available information

David Rode

Affiliation Sensory-Motor Systems Lab, ETH Zurich, Zurich, Switzerland

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2021 in Applied Optics
Verified
Journal Article
Closed access
PDF file
CLConnor Lane
Connor Lane
DRDavid Rode
David Rode
TRThomas Rösgen
Thomas Rösgen
Polarization measurements conducted with a polarization camera using the Sony IMX 250 MZR polarization image sensor are assessed with the super-pixel calibration technique and a simple test setup. We define an error that quantifies the quality of the polarization measurements. Multiple factors influencing the measurement quality of the polarization camera are investigated and discussed. We demonstrate that polarization measurements are generally consistent throughout the sensor if not corrupted by large chief ray angles or large angles of incidence. The central 600 × 400 p i x e l s were analyzed, and it is shown that sufficiently large f -numbers no longer influence measurement quality. We also argue that lens design and focal length have little influence on these central pixels. The findings of this study provide useful guidance for researchers using such a polarization image sensor.

1 November 2021 in Optics and Lasers in Engineering
Verified
Journal Article
Open access
CLConnor Lane
Connor Lane
DRDavid Rode
David Rode
TRThomas Roesgen
Thomas Roesgen

16 September 2021 in Applied Optics
Verified
Journal Article
Closed access
PDF file
CLConnor Lane
Connor Lane
DRDavid Rode
David Rode
TRThomas Rösgen
Thomas Rösgen
A two-dimensional birefringence measurement method is described. In this procedure, we send light through a rotatable linear polarizer and subsequently through a transparent and birefringent specimen. A polarization camera measures the state of linear polarization from which the relative position of the refractive index axes and the relative phase difference is determined. The measurement range of the phase difference is up toπrad, which corresponds to an optical retardation of half the wavelength of the light. The imaging system can measure a large sample area within one measurement cycle. Measurement performance is demonstrated with a quarter-wave plate, and an exemplary test case is shown.

23 July 2026 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DRDavid Rode
David Rode
RWRomina Willi
Romina Willi
ESEva Schulz
Eva Schulz
TSTim Schneller
Tim Schneller
PMPhilipp Moroder
Philipp Moroder
RRRobert Riener
Robert Riener
Clinicians rely on the assessment of joint range of motion to determine the necessity of clinical interventions and to track rehabilitation progress. They often perform visual assessments of these joint angles due to limited time for longer but more accurate methods. Markerless monocular human pose estimation methods could help reduce the workload of physicians in clinical practice, allow patients to conduct regular assessments remotely, and be used to provide reliable assessments in the absence of expert raters, but they have not been validated extensively on clinical populations. We measured the elbow flexion and extension ranges of motion of 46 patients with shoulder and elbow pathologies. These values were assessed by RTMW and HSMR, two different monocular pose estimation methods, and an experienced physician who performed visual assessments. A state-of-the-art passive-marker optical motion capture system was used as the reference system. For elbow flexion, HSMR outperformed visual assessment. HSMR had a higher concordance correlation coefficient of 0.92 and a lower minimal detectable change of 6.74° as determined by a concordance analysis and a linear mixed-effects model. Conversely, for elbow extension, visual assessment outperformed both markerless methods. RTMW was the best-performing markerless method with a concordance correlation coefficient of 0.83 and a minimal detectable change of 7.93°. Thus, HSMR represented a viable alternative to visual assessment for measuring elbow flexion range of motion in a clinical population, but neither RTMW nor HSMR offered an improvement over visual assessment for measuring elbow extension range of motion.