This paper presents a theoretical analysis and simulation for the design and implementation of a Second Order Generalized Integrator - Frequency Locked Loop (SOGI-FLL) aimed at synchronization and fault detection when connecting an inverter to the utility grid. Such an inverter is implemented in a Highly-Efficient-and-Reliable- Inverter-Concept (HERIC) topology. The two main aims of this work are: First, the frequency and phase synchronization of the HERIC power inverter with the grid through the SOGI-FLL. Second, the detection of abnormal conditions that may occur in the coupling point system by analyzing changes in frequency, phase shifts and amplitude variations. This is done by complying with the IEEE 1547 standard for disconnecting generation systems to the grid in case of failure. Finally, from the experimental results, it can be concluded that the SOGI-FLL system is an appropriate alternative for controlling the injection of energy process into the grid, as well as for detecting possible grid faults.
The world is living a steady increase in the electric power demand, an alternative power generation different to conventional is the renewable energy. With the appearance of the Law 1715, Colombia has an incentives policy for the integration of new projects in renewable energies. Because of that, is important to develop studies with real data in the field of the potential of renewable energy resources which can be implemented. This article presents the analysis of the wind generation potential of Tuquerres Savanna, located in the department of Narino. The potential was obtained from the measurement of the wind speed, during the period between the months of June and December of the year 2015. The data were analyzed statistically according to a measure of central tendency, frequency distribution and Weibull distribution for the normalization of scattered data; finally, the power density was calculated according to a horizontal axis wind turbine and the electrical generation potential of the area was simulated. The average wind speeds are 4,4 m/s and the power density founded is 3,47 W/m2.
This paper presents a feasible implementation of a single phase inverter prototype via a Highly Efficient and Reliable Inverter Concept (HERIC) topology, which is connected to the grid through a phase and frequency synchronization system by means of a Second Order Generalized Integrator - Frequency Locked Loop (SOGI-FLL). The chosen topology for the inverter design-unlike a full H-bridge (FB) inverter-incorporates two transistors in the output aimed at preventing reactive power transfer between the output filter and input capacitor when zero-crossing. Furthermore, proposed inverter implementation presents low leakage currents, and increases HERIC system efficiency. Moreover, the SOGI-FLL chosen for connecting the HERIC inverter to the grid provides - even under harmonic distortion - a fast and accurate frequency tracking. The prototype implementation can be divided into two parts: First, the power inverter HERIC is implemented, which holds four transistors MOSFET IRF730 (400V-10A) in a FB topology, as well as two IGBT transistors GP10NC60KD (600V-10A). In addition, in order to protect all the devices and ensure a well transistor conmmuation, four diodes type SF54 (200V-5A) are located between emisor and collector from all transistors. Second, the synchronization system is implemented on an Arduino Due digital platform.
1 April 2019 in Ingeniare. Revista chilena de ingeniería
Los módulos fotovoltaicos presentan una capacidad de generación de potencia dependiente de las condiciones climatológicas de su sitio de ubicación. Este trabajo desarrolla y evalúa un modelo que permite determinar la potencia que generaran los módulos solares basados en tecnologías de silicio, monocristalino, policristalino y amorfo de película delgada, si se conocen las condiciones de temperatura e irradiancia de la zona en la cual planean ser ubicados. El modelo se realizó analizando la respuesta en potencia de diferentes módulos solares ante el comportamiento climatológico de una zona durante un año (datos recolectados por un sistema meteorológico). Los parámetros del modelo se calcularon utilizando el algoritmo cuasi Newton con actualización BFGS. La respuesta en potencia presentada por el modelo se comparó con la respuesta generada por un sistema fotovoltaico real que incluye los tres tipos de tecnología alimentando una carga D.C. evidenciando que la respuesta real corresponde a la estimación entregada por el modelo.
Under standard test conditions (STC) the photovoltaic cells delivers a certain quantity of energy related with the efficiency of the manufacturing technologies, however the operating conditions from a specific place are quite different from STC. This work analyses the amount of energy generated from monocrystalline, polycrystalline and amorphous silicon solar panels under temperature and irradiance conditions of the city of Pasto. This data was collected in the year 2014 using a power acquisition system, DAVIS-vantage Pro2 and Esmera meteorological station, MySQL database and MATLAB. As result this paper presents the statistical analyses and a model that predicts the possible behaviour of the energy generated by each one of the technologies concerning the temperature and irradiance conditions of the city.
Este trabajo forma parte de los desarrollos del grupo de investigación RAMPA de la Institución Universitaria Centro de Estudios Superiores María Goretti, que trabaja la línea de investigación energías renovables con la temática de variables meteorológicas. El estudio se centra en aplicar un modelo de enseñanza-aprendizaje denominado aprendizaje significativo por investigación, cuyo objetivo principal es que los estudiante aprendan a través del diseño la gestión y la evaluación de proyectos pedagógicos trasversales desarrollados a partir del esquema semilleros de investigación con una aplicación de aprendizaje basado en proyectos y enfocados dentro de un proceso investigativo de este grupo de investigación.