Thu Dang

Thu Dang

Auto-generated profile, based on publicly available information

Thu Dang

Radiation Oncology Princess Alexandra Hospital Raymond Terrace South Brisbane Queensland Australia

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2022 in Journal of Medical Radiation Sciences
Verified
Journal Article
Open access
MNMinh Nguyen
Minh Nguyen
TDThu Dang
Thu Dang
LDLiz Deegan
Liz Deegan
KHKelsie Henry
Kelsie Henry
SJScott Jones
Scott Jones
CHCatriona Hargrave
Catriona Hargrave
Introduction: Paediatric patients (individuals below 18 years of age) requiring cranial‐spinal irradiation (CSI) at our institution are commonly planned and treated using a three isocentre (3‐ISO) volumetric modulated arc therapy (VMAT) technique. A modified two isocentre (2‐ISO) VMAT technique was investigated with the aim to improve workflow and reduce planning and treatment time.Methods: Five CSI paediatric patients previously treated with a 3‐ISO VMAT technique were retrospectively replanned using a 2‐ISO VMAT technique. The 2‐ISO VMAT plans were reviewed and approved by a radiation oncologist (RO) before undergoing patient‐specific quality assurance (QA) procedures, performed by a radiation oncology medical physicist (ROMP). Planning target volume (PTV) coverage, organ‐at‐risk (OAR) dose as well as planning and treatment durations of the first five patients utilising 2‐ISO technique were compared with 3‐ISO technique.Results: The average percentage difference in PTV coverage by 95% reference dose between the 2‐ISO and 3‐ISO is 0.14%, and the average difference in OAR median dose is 0.68 Gy. Conformity and homogeneity indices have the same averages at 1.18 and 0.4 respectively. Patient‐specific physics QA results were all comparable with the 3‐ISO averages at 98.84% and the 2‐ISO at 98.71%. Planning duration for the 2‐ISO was reduced by up to 75%, and daily treatment duration was reduced by up to 50%. Of all the previously treated CSI patients using a 3‐ISO technique, 45% were suitable for the 2‐ISO technique.Conclusion: The 2‐ISO VMAT technique provided comparable dose distribution based on PTV coverage, OAR dose and plan metric indices. Reduced planning and treatment duration with the 2‐ISO technique facilitated improved workflow with decreased sedation time for paediatric patients requiring a general anaesthesia.