Dipak Kumar Gupta

Dipak Kumar Gupta

Auto-generated profile, based on publicly available information

Dipak Kumar Gupta

Central Department of Chemistry, Tribhuvan University, Kirtipur, Kathmandu, Nepal

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2021 in Emergent Materials
Verified
Journal Article
Closed access
PDF file
SNShova Neupane
Shova Neupane
VSVivek Subedi
Vivek Subedi
KTKrishna Kumari Thapa
Krishna Kumari Thapa
RYRam Jeevan Yadav
Ram Jeevan Yadav
KNKrishna Badan Nakarmi
Krishna Badan Nakarmi
AYAmar Prasad Yadav
Amar Prasad Yadav

1 March 2021 in Progress in Organic Coatings
Verified
Journal Article
Closed access
DGDipak Kumar Gupta
Dipak Kumar Gupta
SNShova Neupane
Shova Neupane
SSSanjay Singh
Sanjay Singh
NKNabin Karki
Nabin Karki
AYAmar Prasad Yadav
Amar Prasad Yadav

29 January 2021 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
SNShova Neupane
Shova Neupane
SBSuresh Bhusal
Suresh Bhusal
VSVivek Subedi
Vivek Subedi
KNKrishna Badan Nakarmi
Krishna Badan Nakarmi
DGDipak Kumar Gupta
Dipak Kumar Gupta
AYAmar Prasad Yadav
Amar Prasad Yadav
Control of glucose concentration has tremendous significance in medical diagnosis, pharmaceuticals, food, and fermentation industries. Herein, we report on the fabrication of a facile, low‐cost, and sensitive enzyme‐based amperometric sensor using the electrochemically deposited polyaniline (PANI) film on a graphite electrode. PANI was deposited from an aqueous solution of 0.2 M aniline in 1.0 M hydrocholoric acid (HCl) by cyclic voltammetry (CV). Surface morphology and composition characterization of the PANI film were carried out by scanning electron microscopy (SEM), X‐ray photoelectron spectroscopy (XPS), and Fourier‐transform infrared (FTIR) spectroscopy. Potentiostatic immobilization of glucose oxidase (GOX) enzyme in the PANI film was carried out at 0.75 V to fabricate an amperometric glucose biosensor (GOx/PANI/graphite biosensor). The glucose concentration response of the prepared sensor was studied amperometrically by detecting hydrogen peroxide (H2O2). The detection of H2O2 was optimized by calibrating the effects of pH, reduction potential, and background current. A reduction potential of ‐0.4 V at pH 6 was the best combination to get a maximum amperometric response of the GOx/PANI/graphite biosensor. A stable current response was obtained in 4 min with a high reproducibility in linearity within the concentration range of 0.01 M‐0.1 M D‐glucose. Therefore, the fabricated GOx/PANI/graphite biosensor could be a promising candidate for glucose sensing.

1 June 2021 in Heliyon
Verified
Journal Article
Open access
DGDipak Kumar Gupta
Dipak Kumar Gupta
SNShova Neupane
Shova Neupane
HYHarish Chand Yadav
Harish Chand Yadav
VSVivek Subedi
Vivek Subedi
SSSanjay Singh
Sanjay Singh
AYAmar Prasad Yadav
Amar Prasad Yadav
Cu(II) monitoring is a matter of great interest to researchers due to its toxicity and adverse environmental effects. Among different methods for detecting Cu(II), ion-selective electrode (ISE) is more advantageous as they are low-cost, easy to fabricate, and highly selective. Here, we report a simple, inexpensive, and reproducible procedure for the fabrication of Cu(II) ion-selective electrodes using CuS particles and polyvinyl chloride (PVC) as a matrix. CuS particles, obtained by chemical precipitation, were characterized using X-ray diffraction (XRD), Fourier-transform infrared (FTIR) spectroscopy, ultraviolet-visible spectroscopy (UV-Vis), scanning electron microscopy (SEM), and energy-dispersive X-Ray spectroscopy (EDX). Optimization of the membrane compositions was done to get a well-behaved sensor by varying amounts of CuS, PVC, and acetophenone (AP). A membrane composition of 0.4 g CuS, 0.5 g PVC, and 1.0 mL AP in 5.0 mL tetrahydrofuran (THF) gave a Nernstian slope of 27.31 mV per decade change of Cu(II) ion over a wide range of concentration down to 64 ppb (1 × 10−6 M). The sensor gave a fast response time of 25 s, and it indicated the endpoint in a potentiometric titration of Cu(II) with standard EDTA solution. A pH-independent potential response was obtained in the pH 4.0–6.0.

15 March 2021 in Materials and Corrosion
Verified
Journal Article
Closed access
PDF file
SNShova Neupane
Shova Neupane
SHSri Hastuty
Sri Hastuty
NYNeelima Yadav
Neelima Yadav
NSNilima Singh
Nilima Singh
DGDipak K. Gupta
Dipak K. Gupta
AYAmar Prasad Yadav
Amar Prasad Yadav

6 October 2022 in Emergent Materials
Verified
Journal Article
Closed access
PDF file
SPSubash Pandey
Subash Pandey
SNShova Neupane
Shova Neupane
DGDipak Kumar Gupta
Dipak Kumar Gupta
RYRam Jeevan Yadav
Ram Jeevan Yadav
AYAmar Prasad Yadav
Amar Prasad Yadav