Benjamin Petrak

Benjamin Petrak

Auto-generated profile, based on publicly available information

Benjamin Petrak

Department of Physics, University of Basel, Klingelbergstrasse 82, 4056 Basel, Switzerland

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Physical Review Applied
Verified
Journal Article
Open access
PDF file
DNDaniel Najer
Daniel Najer
NTNatasha Tomm
Natasha Tomm
AJAlisa Javadi
Alisa Javadi
AKAlexander R. Korsch
Alexander R. Korsch
BPBenjamin Petrak
Benjamin Petrak
RWRichard J. Warburton
Richard J. Warburton
We present a surface-passivation method that reduces surface-related losses by almost 2 orders of magnitude in a highly miniaturized GaAs open microcavity. The microcavity consists of a curved dielectric distributed Bragg reflector with radius of approximately 10μm paired with a GaAs-based heterostructure. The heterostructure consists of a semiconductor distributed Bragg reflector followed by an n-i-p diode with a layer of quantum dots in the intrinsic region. Free-carrier absorption in the highly-n-doped and highly-p-doped layers is minimized by our positioning them close to a node of the vacuum electromagnetic field. The surface, however, resides at an antinode of the vacuum field and results in significant loss. These losses are much reduced by surface passivation. The strong dependence on wavelength implies that the main effect of the surface passivation is to eliminate the surface electric field, thereby quenching below-band-gap absorption via a Franz-Keldysh-like effect. An additional benefit is that the surface passivation reduces scattering at the GaAs surface. These results are important in other nanophotonic devices that rely on a GaAs-vacuum interface to confine the electromagnetic field.

29 February 2016 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
BPB. Petrak
B. Petrak
JCJ. Cooper
J. Cooper
KKK. Konthasinghe
K. Konthasinghe
MPM. Peiris
M. Peiris
NDN. Djeu
N. Djeu
AMA. Muller
A. Muller
Purcell enhanced Raman scattering (PERS) by means of a doubly resonant Fabry-Perot microcavity (mode volume ≈ 100 μm3 and finesse ≈ 30 000) has been investigated as a technique for isotopic ratio gas analysis. At the pump frequency, the resonant cavity supports a buildup of circulating power while simultaneously enabling Purcell spontaneous emission rate enhancement at the resonant Stokes frequency. The three most common isotopologues of CO2 gas were quantified, and a signal was obtained from 13C16O2 down to a partial pressure of 2 Torr. Due to its small size and low pump power needed (∼10 mW) PERS lends itself to miniaturization. Furthermore, since the cavity is resonant with the emission frequency, future improvements could allow it to serve as its own spectral analyzer and no separate spectroscopic device would be needed.

1 February 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
BPB. Petrak
B. Petrak
MPM. Peiris
M. Peiris
AMA. Muller
A. Muller
We describe a simple and inexpensive optical ring interferometer for use in high-resolution spectral analysis and filtering. It consists of a solid cuboid, reflection-coated on two opposite sides, in which constructive interference occurs for waves in a rhombic trajectory. Due to its monolithic design, the interferometer’s resonance frequencies are insensitive to environmental disturbances over time. Additional advantages are its simplicity of alignment, high-throughput, and feedback-free operation. If desired, it can be stabilized with a secondary laser without disturbance of the primary signal. We illustrate the use of the interferometer for the measurement of the spectral Mollow triplet from a quantum dot and characterize its long-term stability for filtering applications.