Ramiro S. Maldonado

Ramiro S. Maldonado

Auto-generated profile, based on publicly available information

Ramiro S. Maldonado

Department of Ophthalmology, Duke University School of Medicine, Durham, NC, USA

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2011 in Ophthalmology
Verified
Journal Article
Closed access
RMRamiro S. Maldonado
Ramiro S. Maldonado
RORachelle V. O'COnnell
Rachelle V. O'COnnell
NSNeeru Sarin
Neeru Sarin
SFSharon F. Freedman
Sharon F. Freedman
DWDavid K. Wallace
David K. Wallace
CTCynthia A. Toth
Cynthia A. Toth

1 May 2010 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
RMRamiro S. Maldonado
Ramiro S. Maldonado
JIJoseph A. Izatt
Joseph A. Izatt
NSNeeru Sarin
Neeru Sarin
DWDavid K. Wallace
David K. Wallace
SFSharon Freedman
Sharon Freedman
CTCynthia A. Toth
Cynthia A. Toth
Purpose.: To describe age-related considerations and methods to improve hand-held spectral domain optical coherence tomography (HH-SD OCT) imaging of eyes of neonates, infants, and children. Methods.: Based on calculated optical parameters for neonatal and infant eyes, individualized SD OCT scan parameters were developed for improved imaging in pediatric eyes. Forty-two subjects from 31 weeks postmenstrual age to 1.5 years were imaged with a portable HH-SD OCT system. Images were analyzed for quality, field of scan, magnification, and potential clinical utility. Results.: The axial length of the premature infant eye increases rapidly in a linear pattern during the neonatal period and slows progressively with age. Refractive error shifts from mild myopia in neonates to mild hyperopia in infants. These factors affect magnification and field of view of optical diagnostic tools applied to the infant eye. When SD OCT parameters were corrected based on age-related optical parameters, SD OCT image quality improved in young infants. The field of scan and ease of operation also improved, and the optic nerve, fovea, and posterior pole were successfully imaged in 74% and 87% of individual eye imaging sessions in the intensive care nursery and clinic, respectively. No adverse events were reported. Conclusions.: SD OCT in young children and neonates should be customized for the unique optical parameters of the infant eye. This customization, not only improves image quality, but also allows control of the density of the optical sampling directed onto the retina.

1 December 2009 in Ophthalmology
Verified
Journal Article
Closed access
SCSai H. Chavala
Sai H. Chavala
SFSina Farsiu
Sina Farsiu
RMRamiro Maldonado
Ramiro Maldonado
DWDavid K. Wallace
David K. Wallace
SFSharon F. Freedman
Sharon F. Freedman
CTCynthia A. Toth
Cynthia A. Toth

1 November 2009 in Retina
Verified
Journal Article
Closed access
PDPouya N. Dayani
Pouya N. Dayani
RMRamiro Maldonado
Ramiro Maldonado
SFSina Farsiu
Sina Farsiu
CTCynthia A. Toth
Cynthia A. Toth
Purpose: To describe the intraoperative use of handheld spectral domain optical coherence tomography (SDOCT) imaging in macular surgery. Design: Prospective, observational case series. Methods: A handheld SDOCT device was used to obtain preincision optical coherence tomography imaging in patients undergoing vitrectomy for macular diseases. After removal of the internal limiting membrane or the epiretinal membrane, repeat intraoperative imaging was obtained. Spectral domain optical coherence tomography findings were characterized. Results: An efficient technique was established for obtaining intraoperative SDOCT imaging. A total of eight patients were included in the study. Four patients underwent surgery for macular hole, three patients for epiretinal membrane, and one for vitreomacular traction. Comparison of the preincision and intraoperative SDOCT images demonstrated distinct changes in retinal contour and macular hole configuration. Intraoperative SDOCT imaging identified additional membranes in two patients. Conclusion: The intraoperative use of handheld SDOCT imaging provides an efficient method for visualizing macular pathology. This technology may, in certain cases, help confirm or identify diseases that may be difficult to visualize during surgery.

1 May 2011 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
JEJustis P. Ehlers
Justis P. Ehlers
YTYuankai K. Tao
Yuankai K. Tao
SFSina Farsiu
Sina Farsiu
RMRamiro Maldonado
Ramiro Maldonado
JIJoseph A. Izatt
Joseph A. Izatt
CTCynthia A. Toth
Cynthia A. Toth
Purpose.: To demonstrate an operating microscope-mounted spectral domain optical coherence tomography (MMOCT) system for human retinal and model surgery imaging. Methods.: A prototype MMOCT system was developed to interface directly with an ophthalmic surgical microscope, to allow SDOCT imaging during surgical viewing. Nonoperative MMOCT imaging was performed in an Institutional Review Board–approved protocol in four healthy volunteers. The effect of surgical instrument materials on MMOCT imaging was evaluated while performing retinal surface, intraretinal, and subretinal maneuvers in cadaveric porcine eyes. The instruments included forceps, metallic and polyamide subretinal needles, and soft silicone-tipped instruments, with and without diamond dusting. Results.: High-resolution images of the human retina were successfully obtained with the MMOCT system. The optical properties of surgical instruments affected the visualization of the instrument and the underlying retina. Metallic instruments (e.g., forceps and needles) showed high reflectivity with total shadowing below the instrument. Polyamide material had a moderate reflectivity with subtotal shadowing. Silicone instrumentation showed moderate reflectivity with minimal shadowing. Summed voxel projection MMOCT images provided clear visualization of the instruments, whereas the B-scans from the volume revealed details of the interactions between the tissues and the instrumentation (e.g., subretinal space cannulation, retinal elevation, or retinal holes). Conclusions.: High-quality retinal imaging is feasible with an MMOCT system. Intraoperative imaging with model eyes provides high-resolution depth information including visualization of the instrument and intraoperative tissue manipulation. This study demonstrates a key component of an interactive platform that could provide enhanced information for the vitreoretinal surgeon.

1 May 2012 in Archives of Ophthalmology (1950)
Verified
Journal Article
Open access
PDF file
RMRamiro S. Maldonado
Ramiro S. Maldonado
RORachelle O’cOnnell
Rachelle O’cOnnell
SASimon B. Ascher
Simon B. Ascher
NSNeeru Sarin
Neeru Sarin
SFSharon F. Freedman
Sharon F. Freedman
CTCynthia A. Toth
Cynthia A. Toth
Retinopathy of prematurity (ROP) is a multifactorial vascular disease and is the second most common cause of childhood blindness in the United States.1 Timely treatment of ROP is important to prevent disease progression and improve visual outcomes.2 Current guidelines for ROP screening recommend a dilated ophthalmologic examination of the retina.3,4 However, ophthalmoscopic examinations have a degree of subjectivity.5 Wallace et al6 found disagreement in the diagnosis of plus and pre-plus disease among expert examiners. Standard ROP care also has medicolegal liability issues and logistic difficulties that have motivated researchers to seek objective methods to evaluate the severity of ROP. Thus, approaches such as telemedicine,7,8 video indirect recording,9 RetCam imaging (Clarity Medical Systems),10 and computerized image analysis have gained support.11,12