Thrombosis is a deadly malfunctioning of the hemostatic system occurring in numerous conditions and states, from surgery and pregnancy to cancer, sepsis and infarction. Despite availability of antithrombotic agents and vast clinical experience justifying their use, thrombosis is still responsible for a lion’s share of mortality and morbidity in the modern world. One of the key reasons behind this is notorious insensitivity of traditional coagulation assays to hypercoagulation and their inability to evaluate thrombotic risks; specific molecular markers are more successful but suffer from numerous disadvantages. A possible solution is proposed by use of global, or integral, assays that aim to mimic and reflect the major physiological aspects of hemostasis process in vitro. Here we review the existing evidence regarding the ability of both established and novel global assays (thrombin generation, thrombelastography, thrombodynamics, flow perfusion chambers) to evaluate thrombotic risk in specific disorders. The biochemical nature of this risk and its detectability by analysis of blood state in principle are also discussed. We conclude that existing global assays have a potential to be an important tool of hypercoagulation diagnostics. However, their lack of standardization currently impedes their application: different assays and different modifications of each assay vary in their sensitivity and specificity for each specific pathology. In addition, it remains to be seen how their sensitivity to hypercoagulation (even when they can reliably detect groups with different risk of thrombosis) can be used for clinical decisions: the risk difference between such groups is statistically significant, but not large.
Using an in vitro experimental model of immobilized tissue factor-initiated clot growth in platelet-free plasma (thrombodynamics), we observed formation of activator-independent isolated spontaneous clots (SC) throughout the plasma volume in patients with cardiac infarction, acute leukemia, hemolytic anemia, and some other disorders. The aim of this work was to characterize this phenomenon and to identify the mechanisms of SC formation. Tissue factor inhibitor (VIIai) prevented SC in only 2 out of 23 patient plasma samples. Specific inhibitors of factors IXa and XIa were efficient in all 8 cases that we tested. Also, only factors IXa and XIa added to normal donors’ plasma induced SC formations from isolated centers, in a pattern similar to that in patients’ plasma. In contrast, factors VIIa, Va, tissue factor induced uniform plasma clotting. SC disappeared after high-speed centrifugation. However, phospholipid supplementation of centrifuged plasma returned them at least partially in 5 out of 22 patients’ plasmas, indicating some other role of microparticles than providing phospholipid surface. Circulating procoagulant microparticles isolated from plasma directly activated factor XII in buffer and in diluted plasma. Flow cytometry revealed an increase in procoagulant microparticles in patients’ plasmas with SC. Our data suggest that combination of circulating active factors (specifically, factors IXa and XIa) with circulating procoagulant and contact-pathway-activating microparticles is the predominant mechanism causing spontaneous clotting in patient plasma.
For many pathological states, microparticles are supposed to be one of the causes of hypercoagulation. Although there are some indirect data about microparticles participation in coagulation activation and propagation, the integral hemostasis test Thrombodynamics allows to measure micropaticles participation in these two coagulation phases directly. Demonstrates microparticles participation in coagulation activation by influence on the appearance of coagulation centres in the plasma volume and the rate of clot growth from the surface with immobilized tissue factor.Methods: Microparticles were obtained from platelets and erythrocytes by stimulation with thrombin receptor-activating peptide (SFLLRN) and calcium ionophore (A23187), respectively, from monocytes, endothelial HUVEC culture and monocytic THP cell culture by stimulation with lipopolysaccharides. Microparticles were counted by flow cytometry and titrated in microparticle-depleted normal plasma in the Thrombodynamics test. Monocyte microparticles induced the appearance of clotting centres through the TF pathway at concentrations approximately 100-fold lower than platelet and erythrocyte microparticles, which activated plasma by the contact pathway. For endothelial microparticles, both activation pathways were essential, and their activity was intermediate. Monocyte microparticles induced plasma clotting by the appearance of hundreds of clots with an extremely slow growth rate, while erythrocyte microparticles induced the appearance of a few clots with a growth rate similar to that from surface covered with high-density tissue factor. Patterns of clotting induced by platelet and endothelial microparticles were intermediate. Platelet, erythrocyte and endothelial microparticles impacts on the rate of clot growth from the surface with tissue factor did not differ significantly within the 0–200·103/ul range of microparticles concentrations. However, at concentrations greater than 500·103/ul, erythrocyte microparticles increased the stationary clot growth rate to significantly higher levels than do platelet microparticles or artificial phospholipid vesicles consisting of phosphatidylcholine and phosphatidylserine. Microparticles of different origins demonstrated qualitatively different characteristics related to coagulation activation and propagation.
A new oral anticoagulant, dabigatran etexilate (DE, a prodrug of direct thrombin inhibitor (DTI) dabigatran), has been used clinically to prevent thrombosis. The assessment of dabigatran efficiency is necessary in some clinical cases, such as renal insufficiency, risk of bleeding, and drug interactions. However, a specific thrombin generation test (TGT) that is one of the most informative and sensitive to anticoagulant therapy (calibrated automated thrombinography (САТ)) shows a paradoxical increase of test parameters, such as endogenous thrombin potential (ETP) and peak thrombin, in patients receiving DE. The paradoxical behaviour of ETP and peak thrombin in these patients in the presence of DTIs is mostly caused by a decrease in the activity of thrombin in the α2-macroglobulin-thrombin complex that is used as a calibrator in CAT. For a correct estimation of the TGT parameters in patient’s plasma containing DTIs we proposed to use our previously described alternative calibration method that is based on the measurement of the fluorescence signal of a well-known concentration of the reaction product (7-amino-4-methylcoumarin). In this study, the validity of such approach was demonstrated in an ex vivo study in patients with knee replacement and two special patients with multiple myeloma, who received DE for thrombosis prophylaxis.
1 June 2019 in Journal of Molecular Graphics and Modelling