Zheng Zhao

Zheng Zhao

Auto-generated profile, based on publicly available information

Zheng Zhao

Bioengineering Program, The University of Kansas, Lawrence, Kansas 66045, United States

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2015 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
ZZZheng Zhao
Zheng Zhao
YYYang Yang
Yang Yang
YZYong Zeng
Yong Zeng
MHMei He
Mei He
Tumor-derived circulating exosomes, enriched with a group of tumor antigens, have been recognized as a promising biomarker source for cancer diagnosis via a less invasive procedure. Quantitatively pinpointing exosome tumor markers is appealing, yet challenging. In this study, we developed a simple microfluidic approach (ExoSearch) which provides enriched preparation of blood plasma exosomes for in situ, multiplexed detection using immunomagnetic beads. The ExoSearch chip offers a robust, continuous-flow design for quantitative isolation and release of blood plasma exosomes in a wide range of preparation volumes (10 μL to 10 mL). We employed the ExoSearch chip for blood-based diagnosis of ovarian cancer by multiplexed measurement of three exosomal tumor markers (CA-125, EpCAM, CD24) using a training set of ovarian cancer patient plasma, which showed significant diagnostic power (a.u.c. = 1.0, p = 0.001) and was comparable with the standard Bradford assay. This work provides an essentially needed platform for utilization of exosomes in clinical cancer diagnosis, as well as fundamental exosome research.

7 May 2018 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
QZQingfu Zhu
Qingfu Zhu
MHMikala Heon
Mikala Heon
ZZZheng Zhao
Zheng Zhao
Mei HEMei HE
Mei HE
Study of extracellular vesicles (EVs), particularly exosomes, holds significant promise; however, it is technically challenging to define these small and molecularly diverse nanovesicles. With intrinsic molecular payload and biodegradability, molecular engineering of exosomes opens new avenues for mediating cellular responses and developing novel nano-delivery systems in precision therapeutics. Microfluidic lab-on-chip technology is playing pivotal roles in this emerging field. In this review, we have examined scientific advancements of microfluidic technology for engineering exosomes and assessed future applications and perspectives in developing precision therapeutics; this can serve the community via identification of potential new research areas or technologies that are urgently needed in precision therapeutics.

17 April 2019 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
ZZZheng Zhao
Zheng Zhao
JMJodi McGill
Jodi McGill
PGPamela Gamero-Kubota
Pamela Gamero-Kubota
Mei HEMei HE
Mei HE
Extracellular vesicles (EVs), particularly exosomes (30–150 nm), are an emerging delivery system in mediating cellular communications, which have been observed for priming immune responses by presenting parent cell signaling proteins or tumor antigens to immune cells. Therefore, preparation of antigenic exosomes that can play therapeutic roles, particularly in cancer immunotherapy, is emerging. However, standard benchtop methods (e.g., ultracentrifugation and filtration) lack the ability to purify antigenic exosomes specifically among other microvesicle subtypes, due to the non-selective and time-consuming (>10 h) isolation protocols. Exosome engineering approaches, such as the transfection of parent cells, also suffer from poor yields, low purity, and time-consuming operations. In this paper, we introduce a streamlined microfluidic cell culture platform for integration of harvesting, antigenic modification, and photo-release of surface engineered exosomes in one workflow, which enables the production of intact, MHC peptide surface engineered exosomes for cytolysis activation. A PDMS microfluidic cell culture chip is simply cast from a 3D-printed mold. This proof-of-concept study demonstrated the enhanced ability of harvested exosomes in antigen presentation and T cell activation, by decorating melanoma tumor peptides on the exosome surface (e.g., gp-100, MART-1, and MAGE-A3). Such surface engineered antigenic exosomes were harvested in real-time from the on-chip culture of leukocytes isolated from human blood, leading to much faster cellular uptake. The activation of gp100-specific CD8 T cells which were purified from the spleen of 2 Pmel1 transgenic mice was evaluated using surface engineered exosomes prepared from murine antigen presenting cells. Antigen-specific CD8 T cell proliferation was significantly induced by the engineered exosomes compared to that by native, non-engineered exosomes. This microfluidic platform serves as an automated and highly integrated cell culture device for rapid and real-time production of therapeutic exosomes that could advance cancer immunotherapy.

30 September 2022 in Science Advances
Verified
Journal Article
Open access
SGSachindra S. T. Gamage
Sachindra S. T. Gamage
TPThilanga N. Pahattuge
Thilanga N. Pahattuge
HWHarshani Wijerathne
Harshani Wijerathne
KCKatie Childers
Katie Childers
SVSwarnagowri Vaidyanathan
Swarnagowri Vaidyanathan
SSSteven Soper
Steven Soper
We report a microfluidic assay to select active severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) viral particles (VPs), which were defined as intact particles with an accessible angiotensin-converting enzyme 2 receptor binding domain (RBD) on the spike (S) protein, from clinical samples. Affinity selection of SARS-CoV-2 particles was carried out using injection molded microfluidic chips, which allow for high-scale production to accommodate large-scale screening. The microfluidic contained a surface-bound aptamer directed against the virus’s S protein RBD to affinity select SARS-CoV-2 VPs. Following selection (~94% recovery), the VPs were released from the chip’s surface using a blue light light-emitting diode (89% efficiency). Selected SARS-CoV-2 VP enumeration was carried out using reverse transcription quantitative polymerase chain reaction. The VP selection assay successfully identified healthy donors (clinical specificity = 100%) and 19 of 20 patients with coronavirus disease 2019 (COVID-19) (95% sensitivity). In 15 patients with COVID-19, the presence of active SARS-CoV-2 VPs was found. The chip can be reprogrammed for any VP or exosomes by simply changing the affinity agent.

19 June 2023 in Analytical Chemistry
Verified
Journal Article
Open access
SVSwarnagowri Vaidyanathan
Swarnagowri Vaidyanathan
HWHarshani Wijerathne
Harshani Wijerathne
SGSachindra S. T. Gamage
Sachindra S. T. Gamage
FSFarhad Shiri
Farhad Shiri
ZZZheng Zhao
Zheng Zhao
SSSteven Soper
Steven Soper
We present a chip-based extended nano-Coulter counter (XnCC) that can detect nanoparticles affinity-selected from biological samples with low concentration limit-of-detection that surpasses existing resistive pulse sensors by 2-3 orders of magnitude. The XnCC was engineered to contain 5 in-plane pores each with an effective diameter of 350 nm placed in parallel and can provide high detection efficiency for single particles translocating both hydrodynamically and electrokinetically through these pores. The XnCC was fabricated in cyclic olefin polymer (COP) via nanoinjection molding to allow for high-scale production. The concentration limit-of-detection of the XnCC was 5.5 × 103 particles/mL, which was a 1,100-fold improvement compared to a single in-plane pore device. The application examples of the XnCC included counting affinity selected SARS-CoV-2 viral particles from saliva samples using an aptamer and pillared microchip; the selection/XnCC assay could distinguish the COVID-19(+) saliva samples from those that were COVID-19(-). In the second example, ovarian cancer extracellular vesicles (EVs) were affinity selected using a pillared chip modified with a MUC16 monoclonal antibody. The affinity selection chip coupled with the XnCC was successful in discriminating between patients with high grade serous ovarian cancer and healthy donors using blood plasma as the input sample.

3 July 2014 in MOJ Proteomics & Bioinformatics
Verified
Journal Article
Open access
MHMei He
Mei He
ZZZheng Zhao
Zheng Zhao