1 July 2019 in Building and Environment
30 April 2018 in Building Research & Information
Operators’ work order descriptions in computerized maintenance management systems (CMMS) represent an untapped opportunity to benchmark a facility’s maintenance and operation performance. However, it is challenging to carry out analytics on these large and amorphous databases. This paper puts forward a text-mining method to extract information about failure patterns in building systems and components from CMMS databases. The method is executed in three steps. Step 1 is pre-processing to convert work order descriptions into a mathematical form that lends itself to a quantitative lexical analysis. Step 2 is clustering to focus on interesting sections of a CMMS database that contain work orders about failures in building systems and components – rather than less interesting routine maintenance and inspection activities. Step 3 is association rule-mining to identify the coexistence tendencies among the terms of cluster of interest (e.g. coexistence of the terms ‘radiator’ and ‘leak’). This text-mining method is demonstrated by using two data sets. One data set was from a central heating and cooling plant with four boilers and five chillers; the other data set was from a cluster of 44 buildings. The results provide insights into per equipment breakdown of failure events, top system and component-level failure modes, and their occurrence frequencies.
23 June 2017 in Science and Technology for the Built Environment
IBIan Beausoleil-Morrison
In the current article, the thermostat keypress actions with concurrent occupancy, temperature, and relative humidity data in private office spaces were analyzed. The authors observed that the occupants interact with their thermostats infrequently (on average once every 56 h of occupancy); and when they did so, occupants changed the temperature set-point, on average, by 1°C. The authors observed that about one-third of the thermostat overrides were either to decrease the set-points during the heating season, or to increase the set-points during the cooling season. The temperatures leading to the thermostat overrides changed by ∼3°C seasonally. It was noted that the frequency of thermostat interactions can be approximated as a univariate logistic regression model that inputs the indoor temperature as the predictor variable. A recursive algorithm was formulated to develop univariate thermostat use models inside building controllers. It was implemented inside four commercial controllers serving seven private office spaces to choose operating set-points. One year after the implementation, the iterative learning process resulted in a 2°C–3°C reduction in the set-points during the heating season and a 2°C–3°C increase in the set-points during the cooling season with respect to the default 22°C set-point in both seasons.
1 April 2018 in Building and Environment
1 June 2017 in Building and Environment
1 May 2019 in Building and Environment