1 August 2013 in Journal of Composites for Construction
This paper presents the results of an experimental investigation that was carried out to examine the size effect on the shear strength and behavior of concrete beams reinforced with fiber-reinforced polymer (FRP) bars. The beams were reinforced with glass FRP, carbon FRP, and steel bars in the longitudinal direction with no transverse shear reinforcement. Twelve large-scale simply supported beams with different depths, four for each reinforcement type, were tested to determine their shear capacity. The effective depth of the beams was in the range of 300–750 mm. The axial stiffness of the reinforcement was kept the same for beams with the same reinforcement type with different depths. The test results indicated that as the member depth increased, the shear strength at failure decreased for all reinforcement types. The results were compared with Bažant’s size effect law including different parameters, and a reasonably good trend was observed. The shear strength of FRP reinforced beams were also com...
1 April 2012 in Journal of Composites for Construction
This paper examines the effect of depth on the shear strength and behavior of high-strength concrete beams reinforced with glass-fiber-reinforced polymer (GFRP) and carbon-fiber-reinforced polymer (CFRP) bars in the longitudinal direction only without stirrups. Three beams, for each reinforcement type, with depths approximately equal to 300, 450, and 600 mm were tested to determine their shear strength and behavior before and after cracking. The targeted concrete strength was 70 MPa. The tests were carried out using two-point monotonic loading. The test results are presented in terms of crack patterns, load-deflection behavior, and failure modes. It was observed that the shear strength decreased with the increase in the depth of the beams. These results were compared with Bažant size-effect law and a good agreement was observed. The test results were also compared with the predictions using the Canadian Standard Association (CSA) and American Concrete Institute (ACI) shear design equations. The predicted results using the CSA equation were in better agreement with the experimental results than those obtained using the ACI equation.
1 October 2013 in Journal of Composites for Construction
Recent shear tests at Memorial University of Newfoundland that were conducted on beams reinforced with fiber-reinforced polymer (FRP) bars without stirrups showed that there is a relationship between the flexural cracking load and the shear capacity of the beams. Based on this relationship, a simple and unified equation for calculating the concrete contribution to the shear capacity of FRP-reinforced beams is proposed. The proposed equation accounts for the effect of shear span-to-depth ratio, axial stiffness of the longitudinal reinforcement, size of the member, and concrete strength. The prediction of the proposed equation has been evaluated by comparing the calculated shear capacity with the corresponding test results of 132 FRP-reinforced rectangular specimens without stirrups. The predictions of the shear capacity using the proposed equation are compared with those obtained using the shear equations in existing design codes and guidelines for FRP-reinforced beams in Japan and North America. I...
1 August 2013 in Journal of Bridge Engineering
In the current investigation, nondestructive testing (NDT) techniques were applied to evaluate the condition of existing jetty bridge structure. The structure serves as an access point for the loading and unloading of various oil products. The nondestructive strategies included crack-opening measurements using the concrete crack microscope, impact-echo test to measure the depth of the different cracks, and shear-wave testing to detect various defects inside the concrete girders and prestressed ducts. Two AASHTO girders of the jetty were chosen to carry out the various NDTs. The primary objectives of the tests are to assess the overall general condition of the structure and to provide recommendations that could be used to maintain the jetty for its current usage. The combination of the two nondestructive techniques (impact-echo and shear-wave) enabled inspectors to visualize the extension of the cracks in three dimensions and to specify the location of various regions of deterioration within the st...
3 July 2023 in International Journal of Pavement Research and Technology