1 January 2017 in NeuroImage
1 September 2015 in NeuroImage
3 November 2013 in Nature Medicine
There is an urgent need for quantitative magnetic resonance approaches for assessing brain development, as well as for studying the effects of drugs on neural tissue inflammation. Aviv Mezer and colleagues have developed a neuroimaging method for the quantification of local tissue volume and tissue-surface interaction, producing reliable quantitative measurements across a range of scanners. They apply their method to both the healthy brain and individuals with relapsing-remitting multiple sclerosis. Here, we describe a quantitative neuroimaging method to estimate the macromolecular tissue volume (MTV), a fundamental measure of brain anatomy. By making measurements over a range of field strengths and scan parameters, we tested the key assumptions and the robustness of the method. The measurements confirm that a consistent quantitative estimate of MTV can be obtained across a range of scanners. MTV estimates are sufficiently precise to enable a comparison between data obtained from an individual subject with control population data. We describe two applications. First, we show that MTV estimates can be combined with T1 and diffusion measurements to augment our understanding of the tissue properties. Second, we show that MTV provides a sensitive measure of disease status in individual patients with multiple sclerosis. The MTV maps are obtained using short clinically appropriate scans that can reveal how tissue changes influence behavior and cognition.
27 February 2014 in Magnetic Resonance in Medicine
Purpose: There are many T1 mapping methods available, each of them validated in phantoms and reporting excellent agreement with literature. However, values in literature vary greatly, with T1 in white matter ranging from 690 to 1100 ms at 3 Tesla. This brings into question the accuracy of one of the most fundamental measurements in quantitative MRI. Our goal was to explain these variations and look into ways of mitigating them.Theory and Methods: We evaluated the three most common T1 mapping methods (inversion recovery, Look‐Locker, and variable flip angle) through Bloch simulations, a white matter phantom and the brains of 10 healthy subjects (single‐slice). We pooled the T1 histograms of the subjects to determine whether there is a sequence‐dependent bias and whether it is reproducible across subjects.Results: We found good agreement between the three methods in phantoms, but poor agreement in vivo, with the white matter T1 histogram peak in healthy subjects varying by more than 30% depending on the method used. We also found that the pooled brain histograms displayed three distinct white matter peaks, with Look‐Locker consistently underestimating, and variable flip angle overestimating the inversion recovery T1 values. The Bloch simulations indicated that incomplete spoiling and inaccurate B1 mapping could account for the observed differences.Conclusion: We conclude that the three most common T1 mapping protocols produce stable T1 values in phantoms, but not in vivo. To improve the accuracy of T1 mapping, we recommend that sites perform in vivo validation of their T1 mapping method against the inversion recovery reference method, as the first step toward developing a robust calibration scheme. Magn Reson Med 73:514–522, 2015. © 2014 Wiley Periodicals, Inc.
1 January 2018 in NeuroImage
14 September 2012 in Journal of Magnetic Resonance Imaging
HCHai‐Ling Margaret Cheng