Sarah Seko

Sarah Seko

Auto-generated profile, based on publicly available information

Sarah Seko

EECS, UC Berkeley, Berkeley, California United States

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2025 in Cell
Verified
Journal Article
Open access
NNNikhilesh Natraj
Nikhilesh Natraj
SSSarah Seko
Sarah Seko
RAReza Abiri
Reza Abiri
RMRunfeng Miao
Runfeng Miao
HYHongyi Yan
Hongyi Yan
KGKarunesh Ganguly
Karunesh Ganguly
The nervous system needs to balance the stability of neural representations with plasticity. It is unclear what the representational stability of simple well-rehearsed actions is, particularly in humans, and their adaptability to new contexts. Using an electrocorticography brain-computer interface (BCI) in tetraplegic participants, we found that the low-dimensional manifold and relative representational distances for a repertoire of simple imagined movements were remarkably stable. The manifold's absolute location, however, demonstrated constrained day-to-day drift. Strikingly, neural statistics, especially variance, could be flexibly regulated to increase representational distances during BCI control without somatotopic changes. Discernability strengthened with practice and was BCI-specific, demonstrating contextual specificity. Sampling representational plasticity and drift across days subsequently uncovered a meta-representational structure with generalizable decision boundaries for the repertoire; this allowed long-term neuroprosthetic control of a robotic arm and hand for reaching and grasping. Our study offers insights into mesoscale representational statistics that also enable long-term complex neuroprosthetic control.

1 October 2018 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
RMRobert Peter Matthew
Robert Peter Matthew
SSSarah Seko
Sarah Seko
RBRuzena Bajcsy
Ruzena Bajcsy
JLJeffrey Lotz
Jeffrey Lotz
The study of joint kinematics and dynamics has broad clinical applications including the identification of pathological motions or compensation strategies and the analysis of dynamic stability. High-end motion capture systems, however, are expensive and require dedicated camera spaces with lengthy set-up and data processing commitments. Depth cameras, such as the Microsoft Kinect, provide an inexpensive, marker-free alternative at the sacrifice of joint-position accuracy. In this work, we present a fast framework for adding biomechanical constraints to the joint estimates provided by a depth camera system. We also present a new model for the lower lumbar joint angle. We validate key joint position, angle, and velocity measurements against a gold standard active motion-capture system on ten healthy subjects performing sit-to-stand (STS). Our method showed significant improvement in Mean Absolute Error and Intraclass Correlation Coefficients for the recovered joint angles and position-based metrics. These improvements suggest that depth cameras can provide an accurate and clinically viable method of rapidly assessing the kinematics and kinetics of the STS action, providing data for further analysis using biomechanical or machine learning methods.

23 April 2020 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
RMRobert P. Matthew
Robert P. Matthew
SSSarah Seko
Sarah Seko
Gregorij KurilloGregorij Kurillo
Gregorij Kurillo
RBRuzena Bajcsy
Ruzena Bajcsy
LCLouis Cheng
Louis Cheng
JLJeffrey Lotz
Jeffrey Lotz
There are a lack of quantitative measures for clinically assessing upper limb function. Conventional biomechanical performance measures are restricted to specialist labs due to hardware cost and complexity, while the resulting measurements require specialists for analysis. Depth cameras are low cost and portable systems that can track surrogate joint positions. However, these motions may not be biologically consistent, which can result in noisy, inaccurate movements. This paper introduces a rigid body modelling method to enforce biological feasibility of the recovered motions. This method is evaluated on an existing depth camera assessment: the reachable workspace (RW) measure for assessing gross shoulder function. As a rigid body model is used, position estimates of new proximal targets can be added, resulting in a proximal function (PF) measure for assessing a subject's ability to touch specific body landmarks. The accuracy, and repeatability of these measures is assessed on ten asymptomatic subjects, with and without rigid body constraints. This analysis is performed both on a low-cost depth camera system and a gold-standard active motion capture system. The addition of rigid body constraints was found to improve accuracy and concordance of the depth camera system, particularly in lateral reaching movements. Both RW and PF measures were found to be feasible candidates for clinical assessment, with future analysis needed to determine their ability to detect changes within specific patient populations.

1 July 2018
Verified
Conference Paper
Open access
RMRobert Peter Matthew
Robert Peter Matthew
SSSarah Seko
Sarah Seko
JBJeannie Bailey
Jeannie Bailey
RBRuzena Bajcsy
Ruzena Bajcsy
JLJeffrey Lotz
Jeffrey Lotz
Age related spinal deformity is becoming an increasingly prevalent problem, resulting in decreased quality of life. While spinal deformity can be corrected via surgical intervention, a large number of people with spinal fusions require follow-up surgery due to further degeneration. The identification of changes to a subjects kinematics and kinetics post-surgery are limited by a lack of methods to collect patient specific motion data over the course of surgical recovery. This paper introduces an Instrumented Spine Orthosis (ISO) that can capture the motions of the subjects torso without requiring the use of a control computer or other dedicated motion capture equipment. This system is used to collect the peak torso angles and velocities for a single subject performing sit-to-stand actions. The accuracy of the ISO is evaluated using motion capture, during different sit-to-stand protocols designed to highlight motion changes that have been seen in subjects with reduced mobility. This system was found to provide reliable measurements of these kinematic and kinetic torso measures across all tested motions, demonstrating the potential for the use of Instrumented Spine Orthotics to provide quantitative measures during the surgical recovery process.