Philipp Buluschek

Philipp Buluschek

Auto-generated profile, based on publicly available information

Philipp Buluschek

DomoHealth SA, Lausanne, Switzerland

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2021 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
NSNarayan Schütz
Narayan Schütz
HSHugo Saner
Hugo Saner
ABAngela Botros
Angela Botros
BPBruno Pais
Bruno Pais
VSValérie Santschi
Valérie Santschi
TNTobias Nef
Tobias Nef
Background: Population aging is posing multiple social and economic challenges to society. One such challenge is the social and economic burden related to increased health care expenditure caused by early institutionalizations. The use of modern pervasive computing technology makes it possible to continuously monitor the health status of community-dwelling older adults at home. Early detection of health issues through these technologies may allow for reduced treatment costs and initiation of targeted preventive measures leading to better health outcomes. Sleep is a key factor when it comes to overall health and many health issues manifest themselves with associated sleep deteriorations. Sleep quality and sleep disorders such as sleep apnea syndrome have been extensively studied using various wearable devices at home or in the setting of sleep laboratories. However, little research has been conducted evaluating the potential of contactless and continuous sleep monitoring in detecting early signs of health problems in community-dwelling older adults. Objective: In this work we aim to evaluate which contactlessly measurable sleep parameter is best suited to monitor perceived and actual health status changes in older adults. Methods: We analyzed real-world longitudinal (up to 1 year) data from 37 community-dwelling older adults including more than 6000 nights of measured sleep. Sleep parameters were recorded by a pressure sensor placed beneath the mattress, and corresponding health status information was acquired through weekly questionnaires and reports by health care personnel. A total of 20 sleep parameters were analyzed, including common sleep metrics such as sleep efficiency, sleep onset delay, and sleep stages but also vital signs in the form of heart and breathing rate as well as movements in bed. Association with self-reported health, evaluated by EuroQol visual analog scale (EQ-VAS) ratings, were quantitatively evaluated using individual linear mixed-effects models. Translation to objective, real-world health incidents was investigated through manual retrospective case-by-case analysis. Results: Using EQ-VAS rating based self-reported perceived health, we identified body movements in bed—measured by the number toss-and-turn events—as the most predictive sleep parameter (t score=–0.435, P value [adj]=<.001). Case-by-case analysis further substantiated this finding, showing that increases in number of body movements could often be explained by reported health incidents. Real world incidents included heart failure, hypertension, abdominal tumor, seasonal flu, gastrointestinal problems, and urinary tract infection. Conclusions: Our results suggest that nightly body movements in bed could potentially be a highly relevant as well as easy to interpret and derive digital biomarker to monitor a wide range of health deteriorations in older adults. As such, it could help in detecting health deteriorations early on and provide timelier, more personalized, and precise treatment options.

16 August 2022 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
NSNarayan Schütz
Narayan Schütz
SKSamuel E. J. Knobel
Samuel E. J. Knobel
ABAngela Botros
Angela Botros
MSMichael Single
Michael Single
BPBruno Pais
Bruno Pais
TNTobias Nef
Tobias Nef
Using connected sensing devices to remotely monitor health is a promising way to help transition healthcare from a rather reactive to a more precision medicine oriented proactive approach, which could be particularly relevant in the face of rapid population ageing and the challenges it poses to healthcare systems. Sensor derived digital measures of health, such as digital biomarkers or digital clinical outcome assessments, may be used to monitor health status or the risk of adverse events like falls. Current research around such digital measures has largely focused on exploring the use of few individual measures obtained through mobile devices. However, especially for long-term applications in older adults, this choice of technology may not be ideal and could further add to the digital divide. Moreover, large-scale systems biology approaches, like genomics, have already proven beneficial in precision medicine, making it plausible that the same could also hold for remote-health monitoring. In this context, we introduce and describe a zero-interaction digital exhaust: a set of 1268 digital measures that cover large parts of a person’s activity, behavior and physiology. Making this approach more inclusive of older adults, we base this set entirely on contactless, zero-interaction sensing technologies. Applying the resulting digital exhaust to real-world data, we then demonstrate the possibility to create multiple ageing relevant digital clinical outcome assessments. Paired with modern machine learning, we find these assessments to be surprisingly powerful and often on-par with mobile approaches. Lastly, we highlight the possibility to discover novel digital biomarkers based on this large-scale approach.

22 September 2021 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
NSNarayan Schütz
Narayan Schütz
ABAngela Botros
Angela Botros
SHSami Ben Hassen
Sami Ben Hassen
HSHugo Saner
Hugo Saner
PBPhilipp Buluschek
Philipp Buluschek
TNTobias Nef
Tobias Nef
Modern sensor technology is increasingly used in older adults to not only provide additional safety but also to monitor health status, often by means of sensor derived digital measures or biomarkers. Social isolation is a known risk factor for late-life depression, and a potential component of social-isolation is the lack of home visits. Therefore, home visits may serve as a digital measure for social isolation and late-life depression. Late-life depression is a common mental and emotional disorder in the growing population of older adults. The disorder, if untreated, can significantly decrease quality of life and, amongst other effects, leads to increased mortality. Late-life depression often goes undiagnosed due to associated stigma and the incorrect assumption that it is a normal part of ageing. In this work, we propose a visit detection system that generalizes well to previously unseen apartments - which may differ largely in layout, sensor placement, and size from apartments found in the semi-annotated training dataset. We find that by using a self-training-based domain adaptation strategy, a robust system to extract home visit information can be built (ROC AUC = 0.773). We further show that the resulting visit information correlates well with the common geriatric depression scale screening tool ( $\rho =-0.87$ , p = 0.001), providing further support for the idea of utilizing the extracted information as a potential digital measure or even as a digital biomarker to monitor the risk of late-life depression.

31 May 2024 in JMIR Research Protocols
Verified
Journal Article
Open access
BVBenjamin Vögeli
Benjamin Vögeli
NANisha Arenja
Nisha Arenja
NSNarayan Schütz
Narayan Schütz
TNTobias Nef
Tobias Nef
PBPhilipp Buluschek
Philipp Buluschek
HSHugo Saner
Hugo Saner
Background: The results of telemedicine intervention studies in patients with heart failure (HF) to reduce rehospitalization rate and mortality by early detection of HF decompensation are encouraging. However, the benefits are lower than expected. A possible reason for this could be the fact that vital signs, including blood pressure, heart rate, heart rhythm, and weight changes, may not be ideal indicators of the early stages of HF decompensation but are more sensitive for acute events triggered by ischemic episodes or rhythm disturbances. Preliminary results indicate a potential role of ambient sensor–derived digital biomarkers in this setting. Objective: The aim of this study is to identify changes in ambient sensor system–derived digital biomarkers with a high potential for early detection of HF decompensation. Methods: This is a prospective interventional cohort study. A total of 24 consecutive patients with HF aged 70 years and older, living alone, and hospitalized for HF decompensation will be included. Physical activity in the apartment and toilet visits are quantified using a commercially available, passive, infrared motion sensing system (DomoHealth SA). Heart rate, respiration rate, and toss-and-turns in bed are recorded by using a commercially available Emfit QS device (Emfit Ltd), which is a contact-free piezoelectric sensor placed under the participant’s mattress. Sensor data are visualized on a dedicated dashboard for easy monitoring by health professionals. Digital biomarkers are evaluated for predefined signs of HF decompensation, including particularly decreased physical activity; time spent in bed; increasing numbers of toilet visits at night; and increasing heart rate, respiration rate, and motion in bed at night. When predefined changes in digital biomarkers occur, patients will be called in for clinical evaluation, and N-terminal pro b-type natriuretic peptide measurement (an increase of >30% considered as significant) will be performed. The sensitivity and specificity of the different biomarkers and their combinations for the detection of HF decompensation will be calculated. Results: The study is in the data collection phase. Study recruitment started in February 2024. Data analysis is scheduled to start after all data are collected. As of manuscript submission, 5 patients have been recruited. Results are expected to be published by the end of 2025. Conclusions: The results of this study will add to the current knowledge about opportunities for telemedicine to monitor older patients with HF living at home alone by evaluating the potential of ambient sensor systems for this purpose. Timely recognition of HF decompensation could enable proactive management, potentially reducing health care costs associated with preventable emergency presentations or hospitalizations. Trial Registration: ClinicalTrials.gov NCT06126848; https://clinicaltrials.gov/study/NCT06126848 International Registered Report Identifier (IRRID): PRR1-10.2196/55953

19 September 2024 in Journal of Sleep Research
Verified
Journal Article
Open access
HSHugo Saner
Hugo Saner
KMKevin Möri
Kevin Möri
NSNarayan Schütz
Narayan Schütz
PBPhilipp Buluschek
Philipp Buluschek
TNTobias Nef
Tobias Nef
Summary: Little is known about the correlation between subjective perception and objective measures of sleep quality in particular in the oldest‐old. The aim of this study was to perform longitudinal home sleep monitoring in this age group, and to correlate results with self‐reported sleep quality. This is a prospective longitudinal home sleep‐monitoring study in 12 oldest‐old persons (age 83–100 years, mean 93 years, 10 females) without serious sleep disorders over 1 month using a contactless piezoelectric bed sensor (EMFIT QS). Participants provided daily information about perceived sleep. Duration in bed: 264–639 min (M = 476 min, SD = 94 min); sleep duration: 239–561 min (M = 418 min, SD = 91 min); sleep efficiency: 83.9%–90.7% (M = 87.4%, SD = 5.0%); rapid eye movement sleep: 21.1%–29.0% (M = 24.9%, SD = 5.5%); deep sleep: 13.3%–19.6% (M = 16.8%, SD = 4.5%). All but one participant showed a weak (r = 0.2–0.39) or very weak (r = 0–0.19) positive or negative correlation between self‐rated sleep quality and the sleep score. In conclusion, longitudinal sleep monitoring in the home of elderly people by a contactless piezoelectric sensor system is feasible and well accepted. Subjective perception of sleep quality does not correlate well with objective measures in our study. Our findings may help to develop new approaches to sleep problems in the oldest‐old including home monitoring. Further studies are needed to explore the full potential of this approach.

18 August 2025 in JMIR Research Protocols
Verified
Journal Article
Open access
KHKarin Haas
Karin Haas
FSFranziska Scheidegger-Balmer
Franziska Scheidegger-Balmer
AMAndré Meichtry
André Meichtry
BVBenjamin Vögeli
Benjamin Vögeli
NANisha Arenja
Nisha Arenja
HSHugo Saner
Hugo Saner
Background: Sarcopenia, characterized by loss of muscle mass, reduced strength, and increasing frailty, is common in older adults and is often the result of underlying diseases such as advanced stages of heart failure (HF). Protein intake is crucial for maintaining muscle mass and strength. However, older adults typically consume less protein compared to younger individuals. It has recently been shown that the time of the first refrigerator opening in the morning, indicated by a door sensor, may be correlated with frailty in older individuals living alone. Objective: The aim of this study is to determine whether the time of the first refrigerator opening in the morning can serve as a potential indicator of protein intake in older patients (age ≥70 years) after hospitalization for HF decompensation over a period of 6 months. Methods: This is a substudy of a prospective interventional cohort study that aims to identify changes in digital biomarkers derived from an ambient sensor system, which may support the early detection of HF decompensation. In this substudy, the frequency and timing of refrigerator door openings in participants’ homes will be measured. To assess associations between protein intake and refrigerator openings, dietary intake will be evaluated using 24-hour dietary recalls at 3 different timepoints: at 1, 3, and 6 months after hospital discharge. All 24-hour dietary recalls will be conducted by trained dietitians in face-to-face interviews on weekdays. The primary outcome of this study will be the correlation between protein intake and the time (in minutes after midnight) of the first refrigerator door opening at each of the 3 assessment points. Results: The study is currently in the data collection phase. Recruitment began in February 2024. Data analysis will begin after all data have been collected. As of manuscript submission, 12 patients have been recruited. Results are expected to be published by the end of 2025. Conclusions: Considering that protein-rich foods are typically stored in the refrigerator, the relationship between frailty and refrigerator usage may be a relevant indicator for nutritional assessment, particularly regarding protein intake. In addition, sarcopenia and frailty may also be linked to protein distribution across meals. This study will explore whether monitoring refrigerator openings can serve as a simple method for identifying increased risk of frailty and sarcopenia. Early detection through such monitoring could facilitate timely interventions and potentially reduce the risk of these conditions. Trial Registration: ClinicalTrials.gov NCT06126848; https://clinicaltrials.gov/study/NCT06126848 International Registered Report Identifier (IRRID): DERR1-10.2196/66299