Jannis Dickmann

Jannis Dickmann

Auto-generated profile, based on publicly available information

Jannis Dickmann

Siemens Healthineers AG, Forchheim 91301, Germany

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Physics in Medicine & Biology
Verified
Journal Article
Open access
GDGeorge Dedes
George Dedes
JDJannis Dickmann
Jannis Dickmann
KNKatharina Niepel
Katharina Niepel
PWPhilipp Wesp
Philipp Wesp
RJRobert P Johnson
Robert P Johnson
KPKatia Parodi
Katia Parodi
Proton computed tomography (pCT) has been proposed as an alternative to x-ray computed tomography (CT) for acquiring relative to water stopping power (RSP) maps used for proton treatment planning dose calculations. In parallel, it has been shown that dual energy x-ray CT (DECT) improves RSP accuracy when compared to conventional single energy x-ray CT. This study aimed at directly comparing the RSP accuracy of both modalities using phantoms scanned at an advanced prototype pCT scanner and a state-of-the-art DECT scanner. Two phantoms containing 13 tissue-mimicking inserts of known RSP were scanned at the pCT phase II prototype and a latest generation dual-source DECT scanner (Siemens SOMATOM Definition FORCE). RSP accuracy was compared by mean absolute percent error (MAPE) over all inserts. A highly realistic Monte Carlo (MC) simulation was used to gain insight on pCT image artifacts which degraded MAPE. MAPE was 0.55% for pCT and 0.67% for DECT. The realistic MC simulation agreed well with pCT measurements ( ). Both simulation and experimental results showed ring artifacts in pCT images which degraded the MAPE compared to an ideal pCT simulation ( ). Using the realistic simulation, we could identify sources of artifacts, which are attributed to the interfaces in the five-stage plastic scintillator energy detector and calibration curve interpolation regions. Secondary artifacts stemming from the proton tracker geometry were also identified. The pCT prototype scanner outperformed a state-of-the-art DECT scanner in terms of RSP accuracy (MAPE) for plastic tissue mimicking inserts. Since artifacts tended to concentrate in the inserts, their mitigation may lead to further improvements in the reported pCT accuracy.

1 July 2019 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
JDJannis Dickmann
Jannis Dickmann
PWPhilipp Wesp
Philipp Wesp
MRMartin Rädler
Martin Rädler
SRSimon Rit
Simon Rit
MPMark Pankuch
Mark Pankuch
GDGeorgios Dedes
Georgios Dedes
We present a method to accurately predict image noise in proton computed tomography (pCT) using data generated from a Monte Carlo simulation and a patient or object model that may be generated from a prior x-ray CT image. This enables noise prediction for arbitrary beam fluence settings and, therefore, the application of fluence-modulated pCT (FMpCT), which can achieve prescribed noise targets and may significantly reduce the integral patient dose. We extended an existing Monte Carlo simulation of a prototype pCT scanner to include effects of quenching in the energy detector scintillators and constructed a beam model from experimental tracking data. Simulated noise predictions were compared to experimental data both in the projection domain and in the reconstructed image. Noise prediction agreement between simulated and experimental data in terms of the root-mean-square (RMS) error was better than 7% for a homogeneous water phantom and a sensitometry phantom with tubular inserts. For an anthropomorphic head phantom, modeling the anatomy of a five-year-old child, the RMS error was better than 9% in three evaluated slices. We were able to reproduce subtle noise features near heterogeneities. To demonstrate the feasibility of Monte Carlo simulated noise maps for fluence modulation, we calculated a fluence profile that yields a homogeneous noise level in the image. Unlike for bow-tie filters in x-ray CT this does not require constant fluence at the detector and the shape of the fluence profile is fundamentally different. Using an improved Monte Carlo simulation, we demonstrated the feasibility of using simulated data for accurate image noise prediction for pCT. We believe that the agreement with experimental data is sufficient to enable the future optimization of FMpCT fluence plans to achieve prescribed noise targets in a fluence-modulated acquisition.

1 February 2018 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Closed access
AMAndreas Maier
Andreas Maier
UWUli Weber
Uli Weber
JDJannis Dickmann
Jannis Dickmann
JBJoachim Breckow
Joachim Breckow
PBPatrick van Beek
Patrick van Beek
CFClaudia Fournier
Claudia Fournier

10 February 2020 in Medical Physics
Verified
Journal Article
Open access
PDF file
JDJ. Dickmann
J. Dickmann
SRS. Rit
S. Rit
MPM. Pankuch
M. Pankuch
RJR. P. Johnson
R. P. Johnson
RSR. W. Schulte
R. W. Schulte
GLGuillaume Landry
Guillaume Landry
Purpose: Fluence‐modulated proton computed tomography (FMpCT) using pencil beam scanning aims at achieving task‐specific image noise distributions by modulating the imaging proton fluence spot‐by‐spot based on an object‐specific noise model. In this work, we present a method for fluence field optimization and investigate its performance in dose reduction for various phantoms and image variance targets.Methods: The proposed method uses Monte Carlo simulations of a proton CT (pCT) prototype scanner to estimate expected variance levels at uniform fluence. Using an iterative approach, we calculate a stack of target variance projections that are required to achieve the prescribed image variance, assuming a reconstruction using filtered backprojection. By fitting a pencil beam model to the ratio of uniform fluence variance and target variance, relative weights for each pencil beam can be calculated. The quality of the resulting fluence modulations is evaluated by scoring imaging doses and comparing them to those at uniform fluence, as well as evaluating conformity of the achieved variance with the prescription. For three different phantoms, we prescribed constant image variance as well as two regions‐of‐interest (ROI) imaging tasks with inhomogeneous image variance. The shape of the ROIs followed typical beam profiles for proton therapy.Results: Prescription of constant image variance resulted in a dose reduction of 8.9% for a homogeneous water phantom compared to a uniform fluence scan at equal peak variance level. For a more heterogeneous head phantom, dose reduction increased to 16.0% for the same task. Prescribing two different ROIs resulted in dose reductions between 25.7% and 40.5% outside of the ROI at equal peak variance levels inside the ROI. Imaging doses inside the ROI were increased by 9.2% to 19.2% compared to the uniform fluence scan, but can be neglected assuming that the ROI agrees with the therapeutic dose region. Agreement of resulting variance maps with the prescriptions was satisfactory.Conclusions: We developed a method for fluence field optimization based on a noise model for a real scanner used in pCT. We demonstrated that it can achieve prescribed image variance targets. A uniform fluence field was shown not to be dose optimal and dose reductions achievable with the proposed method for FMpCT were considerable, opening an interesting perspective for image guidance and adaptive therapy.

22 September 2020 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
JDJannis Dickmann
Jannis Dickmann
CSChristina Sarosiek
Christina Sarosiek
VRVictor Rykalin
Victor Rykalin
MPMark Pankuch
Mark Pankuch
SRSimon Rit
Simon Rit
GDGeorgios Dedes
Georgios Dedes
Proton computed tomography (pCT) has high accuracy and dose efficiency in producing spatial maps of the relative stopping power (RSP) required for treatment planning in proton therapy. With fluence-modulated pCT (FMpCT), prescribed noise distributions can be achieved, which allows to decrease imaging dose by employing object-specific dynamically modulated fluence during the acquisition. For FMpCT acquisitions we divide the image into region-of-interest (ROI) and non-ROI volumes. In proton therapy, the ROI volume would encompass all treatment beams. An optimization algorithm then calculates dynamically modulated fluence that achieves low prescribed noise inside the ROI and high prescribed noise elsewhere. It also produces a planned noise distribution, which is the expected noise map for that fluence, as calculated with a Monte Carlo simulation. The optimized fluence can be achieved by acquiring pCT images with grids of intensity modulated pencil beams. In this work, we interfaced the control system of a clinical proton beam line to deliver the optimized fluence. Using three phantoms we acquired images with uniform fluence, with a constant noise prescription, and with an FMpCT task. Image noise distributions as well as fluence maps were compared to the corresponding planned distributions as well as to the prescription. Furthermore, we propose a correction method that removes image artifacts stemming from the acquisition with pencil beams having a spatially varying energy distribution that is not seen in clinical operation. RSP accuracy of FMpCT scans was compared to uniform scans and was found to be comparable to standard pCT scans. While we identified technical improvements for future experimental acquisitions, in particular related to an unexpected pencil beam size reduction and a misalignment of the fluence pattern, agreement with the planned noise was satisfactory and we conclude that FMpCT optimized for specific image noise prescriptions is experimentally feasible.

9 March 2018
Verified
Conference Paper
Closed access
PDF file
JDJannis Dickmann
Jannis Dickmann
JMJoscha Maier
Joscha Maier
SSStefan Sawall
Stefan Sawall
MKMarc Kachelriess
Marc Kachelriess
CBChristian Broennimann
Christian Broennimann
SGSpyridon Gkoumas
Spyridon Gkoumas
Raw-data–based material decomposition in spectral CT using photon–counting energy–selective detectors relies on a precise forward model that predicts a count–rate given intersection lengths for each material. This re- quires extensive system–specific measurements or calibration techniques. Existing calibrations either estimate a detected spectrum and are able to account for spectrally distorted assumptions or correct the predicted count rate using a correction function and can accommodate for count rate–dependent effects such as pulse pileup. We propose a calibration method that uses transmission measurements to optimize a correction function that, unlike existing methods, depends both on the photon energy and the count rate. It is thus able to correct for both kinds of distortions. In a simulated material decomposition into water and iodine, the error was reduced by 96 % compared to the best performing reference method if only pulse pileup was present and reduced by 23 % if additionally spectral distortions were taken into account. In phantom measurements using a Dectris SANTIS prototype detector, the proposed method allowed to reduce the error by 29 % compared to the best performing reference method. Artifacts were below the noise level for the proposed method, while the reference methods either showed an offset in the water region or ring artifacts.