David Michael Lane Cooper

David Michael Lane Cooper

Auto-generated profile, based on publicly available information

David Michael Lane Cooper

Department of Anatomy, Physiology, and Pharmacology, University of Saskatchewan, Saskatoon, Canada

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2016 in Current Osteoporosis Reports
Verified
Journal Article
Closed access
PDF file
DCD. M. L. Cooper
D. M. L. Cooper
CKC. E. Kawalilak
C. E. Kawalilak
KHK. Harrison
K. Harrison
BJB. D. Johnston
B. D. Johnston
JJJ. D. Johnston
J. D. Johnston

1 January 2013 in Bone
Verified
Journal Article
Closed access
YCYasmin Carter
Yasmin Carter
CTC. David L. Thomas
C. David L. Thomas
JCJohn G. Clement
John G. Clement
APAndrew G. Peele
Andrew G. Peele
KHKevin Hannah
Kevin Hannah
DCDavid M.L. Cooper
David M.L. Cooper

1 September 2013 in Journal of Structural Biology
Verified
Journal Article
Closed access
YCYasmin Carter
Yasmin Carter
CTC. David L. Thomas
C. David L. Thomas
JCJohn G. Clement
John G. Clement
DCDavid M.L. Cooper
David M.L. Cooper

1 December 2017 in Bone Reports
Verified
Journal Article
Open access
AAA.M. Ashique
A.M. Ashique
LHL.S. Hart
L.S. Hart
CTC.D.L. Thomas
C.D.L. Thomas
JCJ.G. Clement
J.G. Clement
PPPeter Pivonka
Peter Pivonka
DCD.M.L. Cooper
D.M.L. Cooper
The lacunar-canalicular network (LCN) of bone contains osteocytes and their dendritic extensions, which allow for intercellular communication, and are believed to serve as the mechanosensors that coordinate the processes of bone modeling and remodeling. Imbalances in remodeling, for example, are linked to bone disease, including fragility associated with aging. We have reported that there is a reduction in scale for one component of the LCN, osteocyte lacunar volume, across the human lifespan in females. In the present study, we explore the hypothesis that canalicular porosity also declines with age. To visualize the LCN and to determine how its components are altered with aging, we examined samples from young (age: 20-23 y; n = 5) and aged (age: 70-86 y; n = 6) healthy women donors utilizing a fluorescent labelling technique in combination with confocal laser scanning microscopy. A large cross-sectional area of cortical bone spanning the endosteal to periosteal surfaces from the anterior proximal femoral shaft was examined in order to account for potential trans-cortical variation in the LCN. Overall, we found that LCN areal fraction was reduced by 40.6% in the samples from aged women. This reduction was due, in part, to a reduction in lacunar density (21.4% decline in lacunae number per given area of bone), but much more so due to a 44.6% decline in canalicular areal fraction. While the areal fraction of larger vascular canals was higher in endosteal vs. periosteal regions for both age groups, no regional differences were observed in the areal fractions of the LCN and its components for either age group. Our data indicate that the LCN is diminished in aged women, and is largely due to a decline in the canalicular areal fraction, and that, unlike vascular canal porosity, this diminished LCN is uniform across the cortex.

6 June 2011 in Journal of Anatomy
Verified
Journal Article
Open access
PDF file
DCD. M. L. Cooper
D. M. L. Cooper
BEB. Erickson
B. Erickson
APA.G. Peele
A.G. Peele
KHK. Hannah
K. Hannah
CTC. D. L. Thomas
C. D. L. Thomas
JCJ. G. Clement
J. G. Clement
Cortical bone histology has been the subject of scientific inquiry since the advent of the earliest microscopes. Histology – literally the study of tissue – is a field nearly synonymous with 2D thin sections. That said, progressive developments in high‐resolution X‐ray imaging are enabling 3D visualization to reach ever smaller structures. Micro‐computed tomography (micro‐CT), employing conventional X‐ray sources, has become the gold standard for 3D analysis of trabecular bone and is capable of detecting the structure of vascular (osteonal) porosity in cortical bone. To date, however, direct 3D visualization of secondary osteons has eluded micro‐CT based upon absorption‐derived contrast. Synchrotron radiation micro‐CT, through greater image quality, resolution and alternative contrast mechanisms (e.g. phase contrast), holds great potential for non‐destructive 3D visualization of secondary osteons. Our objective was to demonstrate this potential and to discuss areas of bone research that can be advanced through the application of this approach. We imaged human mid‐femoral cortical bone specimens derived from a 20‐year‐old male (Melbourne Femur Collection) at the Advanced Photon Source synchrotron (Chicago, IL, USA) using the 2BM beam line. A 60‐mm distance between the target and the detector was employed to enhance visualization of internal structures through propagation phase contrast. Scan times were 1 h and images were acquired with 1.4‐μm nominal isotropic resolution. Computer‐aided manual segmentation and volumetric 3D rendering were employed to visualize secondary osteons and porous structures, respectively. Osteonal borders were evident via two contrast mechanisms. First, relatively new (hypomineralized) osteons were evident due to differences in X‐ray attenuation relative to the surrounding bone. Second, osteon boundaries (cement lines) were delineated by phase contrast. Phase contrast also enabled the detection of soft tissue remnants within the vascular pores. The ability to discern osteon boundaries in conjunction with vascular and cellular porosity revealed a number of secondary osteon morphologies and provided a unique 3D perspective of the superimposition of secondary osteons on existing structures. Improvements in resolution and optimization of the propagation phase contrast promise to provide further improvements in structural detail in the future.

15 September 2010 in Journal of Microscopy
Verified
Journal Article
Closed access
PDF file
HBH.M. Britz
H.M. Britz
JJJ. Jokihaara
J. Jokihaara
OLO.V. Leppänen
O.V. Leppänen
TJT. Järvinen
T. Järvinen
DCD.M.L. Cooper
D.M.L. Cooper