11 May 2018 in IEEE Transactions on Power Systems
The paper proposes a new adaptive approach to power system model reduction for fast and accurate time-domain simulation. This new approach is a compromise between linear model reduction for faster simulation and nonlinear model reduction for better accuracy. During the simulation period, the approach adaptively switches among detailed and linearly or nonlinearly reduced models based on variations of the system state: it employs unreduced models for the fault-on period, uses weighted column norms of the admittance matrix to decide which functions to be linearized in power system differential-algebraic equations for large changes of the state, and adopts a linearly reduced model for small changes of the state. Two versions of the adaptive model reduction approach are introduced. The first version uses traditional power system partitioning where the model reduction is applied to a defined large external area in a power system and the other area defined as the study area keeps full detailed models. The second version applies the adaptive model reduction to the whole system. The paper also conducts comprehensive case studies comparing simulation results using the proposed adaptively reduced models with the linearly reduced model and coherency-based reduced model on the Northeast Power Coordinating Council 140-bus 48-machine system.
6 May 2020 in IEEE Transactions on Power Systems
The paper proposes a new approach for the recovery of missing data from phasor measurement units (PMUs). The approach is based on the application of tensor decomposition to PMU data organized as three-dimensional tensors with respect to time, location and type of variables. The organization of the PMU data is in the form of a bus-oriented data structure and a branch-oriented data structure. Two versions of the approach are introduced. The first version uses polyadic tensor decomposition and the second version uses Tucker tensor decomposition. Several case studies are conducted validating the proposed approaches including measured PMU data in the New York transmission system. Comparison with existing approaches is performed to demonstrate the improvement in missing data recovery accuracy achieved by the new approach.
14 December 2022 in IEEE Transactions on Power Systems
This article proposes a new measurement-based approach for locating the sources of forced or poorly damped oscillations in a power system. The approach is based on the concept of cross-correlation in the frequency domain known as cross-power spectral density (CPSD). CPSDs of synchronized voltage magnitude and voltage angle versus active power and reactive power signals obtained by phasor measurement units (PMUs) are computed using fast Fourier transform. The largest positive imaginary part of a CPSD is used as an indicator of the oscillation source. The type of an oscillation source is determined by comparing the spectral densities of active and reactive power. In addition, preprocessing of the signals is performed via variational mode decomposition for extracting the dynamic component of the signals. The proposed approach was able to successfully identify all submitted test cases in the IEEE-NASPI Oscillation Source Location Contest. Several case studies presented in this article highlight the advantages of the proposed approach compared to the state-of-the-art dissipating energy flow method.
1 May 2019 in IEEE Transactions on Industry Applications
Battery energy storage systems (BESSs) tend to be too costly, restrictive, and high-maintenance for experimental use, but power system tests often need their representation. As a solution, we propose an all-in-one, reconfigurable BESS emulation tool for grid applications that only requires one three-phase voltage source converter. This emulator provides chemistry-specific battery behavior like previous work, but it also includes the BESS's power electronics interface and control as well as automatic frequency and voltage support functions for the attached power system. Thus, it allows simple, plug-and-play BESS emulation for grid applications. This paper details the construction, verification, and use of the BESS emulator in an existing grid testbed and concludes that it provides an inexpensive, easy-to-use alternative to using real BESSs in power system experiments.
18 May 2022 in Proceedings of the IEEE
High penetration of converter-interfaced renewable energy resources will significantly change the swing dynamics between synchronous generators (SGs) in future power systems. This article examines the impact of high converter penetration on wave-like disturbance propagation arising from sudden generator and load losses in radial (1-D) and meshed (2-D) power systems. To keep the uniformity assumption as converters are introduced, the rating of each SG is decreased with a converter resource making up for the reduction. Numerical simulations demonstrate that as the penetration level of constant-power grid-following (GFL) converters increases, the speed of disturbance propagation increases due to the reduced system inertia. Naturally, converters with the capabilities to positively respond to disturbances would in turn reduce the propagation speed. Analytical studies based on continuum models are presented for the 2-D system with SGs and constant-power GFL converters in order to visualize the disturbance propagation and validate numerical simulations based on differential-algebraic equations. In addition, fast active power control of converters can slow down the electromechanical wave (EMW) propagation and even contain it. These concepts are illustrated on the idealized radial and meshed systems and a reduced model of the U.S. eastern interconnection.