This paper investigates the effect of geocomposite layers (as an internal drainage system) and a chimney sand drain (as an external drainage system) on the performance of reinforced soil walls with panel facing and marginal backfill. Four models subjected to seepage simulating a rising groundwater surface were tested at 40 gravities using a 4.5 m radius large beam centrifuge. In this study, geocomposite layers played a dual function of drainage and reinforcement. The behavior of wall models was monitored using displacement and pore water pressure transducers during centrifuge tests. An image analysis technique was also used to measure displacement and strain fields. A geogrid reinforced soil wall with no drainage system experienced catastrophic failure at the onset of seepage. Provision of geocomposite layers at the bottom portion of the wall improved the wall behavior. Further, including geocomposite layers up to the mid-height of the wall resulted in superior performance compared to geogrid-reinforced soil walls. The model with the chimney sand drain experienced piping failure at the toe of the wall. The performance of reinforced soil walls with geocomposite layers was found to be superior to the geogrid reinforced soil walls with the chimney drain.