27 June 2016 in Journal of the Optical Society of America A
We introduce a spectrometer capable of measuring sample absorption spectra in the visible regime, based on a time-domain scanning Fourier transform (FT) approach. While infrared FT spectrometers typically employ a Michelson interferometer to create the two delayed light replicas, the proposed apparatus exploits a compact common-mode passive interferometer that relies on the use of birefringent wedges. This ensures excellent path-length stability () and accuracy, with no need for active feedback or beam tracking. We demonstrate the robustness of the technique measuring the transmission spectrum of a colored bandpass filter over one octave of bandwidth and compare the results with those obtained with a commercial spectrophotometer.
21 May 2019 in Optics Express
We introduce a high-performance hyperspectral camera based on the Fourier-transform approach, where the two delayed images are generated by the Translating-Wedge-Based Identical Pulses eNcoding System (TWINS) [Opt. Lett. 37, 3027 (2012)], a common-path birefringent interferometer that combines compactness, intrinsic interferometric delay precision, long-term stability and insensitivity to vibrations. In our imaging system, TWINS is employed as a time-scanning interferometer and generates high-contrast interferograms at the single-pixel level. The camera exhibits high throughput and provides hyperspectral images with spectral background level of −30dB and resolution of 3 THz in the visible spectral range. We show high-quality spectral measurements of absolute reflectance, fluorescence and transmission of artistic objects with various lateral sizes.
12 April 2018 in Optics Letters
We introduce a novel configuration for the broadband measurement of the optical activity of molecules, combining time-domain detection with heterodyne amplification. A birefringent common-path polarization-division interferometer creates two phase-locked replicas of the input light with orthogonal polarization. The more intense replica interacts with the sample, producing a chiral free-induction decay field, which interferes with the other replica, acting as a time-delayed phase-coherent local oscillator. By recording the delay-dependent interferogram, we obtain by a Fourier transform both the circular dichroism and circular birefringence spectra. Our compact, low-cost setup accepts ultrashort light pulses, making it suitable for measurement of transient optical activity.
23 June 2016 in Optics Letters
DVDiana Gisell Figueroa del Valle
Diana Gisell Figueroa del Valle
We introduce an innovative high-sensitivity broadband pump-probe spectroscopy system, based on Fourier-transform detection, operating at 20-MHz modulation frequency. A common-mode interferometer employing birefringent wedges creates two phase-locked delayed replicas of the broadband probe pulse, interfering at a single photodetector. A single-channel lock-in amplifier demodulates the interferogram, whose Fourier transform provides the differential transmission spectrum. Our approach combines broad spectral coverage with high sensitivity, due to high-frequency modulation and detection. We demonstrate its performances by measuring two-dimensional differential transmission maps of a carbon nanotubes sample, simultaneously acquiring the signal over the entire 950–1350 nm range with noise over 1.5 s integration time.
24 August 2023 in The Journal of Chemical Physics
Nonlinear spectroscopy with quantum entangled photons is an emerging field of research that holds the promise to achieve superior signal-to-noise ratio and effectively isolate many-body interactions. Photon sources used for this purpose, however, lack the frequency tunability and spectral bandwidth demanded by contemporary molecular materials. Here, we present design strategies for efficient spontaneous parametric downconversion to generate biphoton states with adequate spectral bandwidth and at visible wavelengths. Importantly, we demonstrate, by suitable design of the nonlinear optical interaction, the scope to engineer the degree of spectral correlations between the photons of the pair. We also present an experimental methodology to effectively characterize such spectral correlations. Importantly, we believe that such a characterization tool can be effectively adapted as a spectroscopy platform to optically probe system–bath interactions in materials.
1 October 2025 in APL Photonics
We present a compact hyperspectral camera based on the Fourier-transform approach working in the thermal infrared (TIR) spectral region. The system is based on a common-path birefringent interferometer, made with the TIR transparent material calomel (Hg2Cl2), ensuring the generation of phase-locked light replicas and characterized by high delay accuracy, long-term stability and compactness. Compared to previous designs, the interferometer presented here greatly improves the spatial coherence of the replicas, enabling its applications also to the challenging TIR range. We demonstrate interferometric contrast higher than 90%, spectral resolution below 4.5 cm−1, and a spectral coverage between 3 and 14 μm, limited only by the detector and its optical components. By coupling the interferometer to an uncooled microbolometer with 640 × 480 pixels, we demonstrate hyperspectral imaging in the 8–14 μm range, remotely acquiring emission and transmission spectra from each point of a scene.