Amit Kumar Singh

Amit Kumar Singh

Auto-generated profile, based on publicly available information

Amit Kumar Singh

Department of Biomedical Engineering, Vignan's Foundation for Science, Technology & Research, Vadlamudi, Guntur. Andhra Pradesh, India

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ASAmit Kumar Singh
Amit Kumar Singh
SJSandeep Kumar Jha
Sandeep Kumar Jha
We report the method for fabrication and validation of a standalone handheld optical biosensor for non-invasive monitoring of glucose using saliva. For this, a biodegradable, low cost test strip for glucose was developed by co-immobilizing glucose oxidase enzyme and bromocresol purple pH sensitive dye. The enzymatic reaction produced pH change and thus a change in color of filter paper strip which was detected by a standalone electronic meter. The in-house developed meter consisted of an optically isolated region in the chassis for inserting the test strip along with the sample to avoid interferences from ambient wind and light. The developed biosensor had wide detection range of detection between 32-516 mg/dL glucose concentration while the sensitivity of detection was 1.0 mg/dL/count at a LOD of 32 mg/dL within a response time of 15 sec. The device along with strips were validated on clinical samples while comparing salivary glucose level with that of blood glucose level using a commercial glucometer. A very good correlation was found for diabetic individuals (0.80) whereas, it was less significant (0.53) for non-diabetic individuals. The device passed Clarke’s error grid analysis and hence should be medically acceptable. This simple and low-cost setup should be ideally suited for mass screening of diabetes, apart from being used as a self-monitoring device in a non-invasive and painless manner.

10 October 2016 in Analytical Sciences
Verified
Journal Article
Open access
PDF file
ASAmit Kumar Singh
Amit Kumar Singh
ARAppan Roychoudhury
Appan Roychoudhury
SJSandeep Kumar Jha
Sandeep Kumar Jha
In this paper, an egg-shell membrane has been used for efficient immobilization and stabilization of glucose oxidase. This membrane was used for developing a simple and reusable method for estimation of glucose in biological samples. The proposed sensor was effectively used in a wide glucose concentration range (1 - 1000 mM) with fast response time of 70 s for higher concentrations and 120 s for lower concentrations. The results of response study for the fabricated sensor show limit of detection of 4.761 mM with high sensitivity over the entire concentration range (1 - 1000 mM). Most interestingly, the membrane used in the fabricated sensor could be repeatedly used for glucose analysis 150 times and it exhibited a shelf-life of more than 6 weeks. The proposed sensor was also demonstrated for estimation of glucose in human blood samples.

1 December 2013
Verified
Conference Paper
Closed access
SCS. Chatterji
S. Chatterji
SSS. L. Shimi
S. L. Shimi
ASAmit Kumar Singh
Amit Kumar Singh
AGAnshul Gaur
Anshul Gaur
Web enabled Laboratory implementation of Instrumentation Lab is shown in this work. Many measurement principles are used in this course. Many principles related with Instrumentation can be demonstrated by means of Web enabled laboratory and it is the advancement in Instrumentation course teaching. The characteristic of LM35, Pt100 and Thermistor is shown in this work. By using LabVIEW developing software investigator has developed the remote laboratory for engineering students. The circuits as well as the combination of real and virtual are novel. The remote laboratories were developed using LabVIEW virtual instrumentation and they enable web control and monitoring of the laboratory equipment, allowing engineering students to perform the experiments in real time, at their own computers, from anywhere and whenever is suitable for them and also at reduced cost.


30 April 2024 in JOURNAL OF CLINICAL AND BIOMEDICAL SCIENCES
Verified
Journal Article
Open access
PDF file
SKSingh Amit Kumar
Singh Amit Kumar
JTJain Tushar
Jain Tushar
Three-dimensional printing (3DP), also known as additive manufacturing, has significantly impacted the biomedical field by enabling the creation of complex, patient-specific medical devices, implants, and tissues. The need for advanced medical solutions due to an aging population and increased reliance on electronic gadgets has driven research into 3DP application. This review focuses on the various biomedical applications of 3DP, including drug synthesis, medical device fabrication, bioprinting, and surgical planning. The review discusses key techniques such as bioprinting, which combines cells, growth factors, and biomaterials to create tissue-like structures, and the use of 3DP for patient-specific prostheses and orthoses. Additionally, the role of 3DP in tissue engineering, organ printing, and the development of bioactive and biodegradable scaffolds is explored. The findings highlight the versatility of 3DP in creating patient-specific medical devices, enhancing surgical outcomes, and advancing tissue engineering and regenerative medicine. Different 3DP techniques discussed also shows promise in producing robust and biocompatible implants, while challenges remain in the widespread application of bio printed organs and tissues. 3DP has the potential to revolutionize the biomedical field by providing customized, efficient, and effective solutions for various medical challenges. Keywords: Three-dimensional printing, Bioprinting, Biomedical applications, Tissue engineering, Patient-specific implants, Regenerative medicine, Additive manufacturing

18 November 2025 in RSC Advances
Verified
Journal Article
Open access
PDF file
ASAmit Kumar Singh
Amit Kumar Singh
SPShweta Panwar
Shweta Panwar
SJSandeep Kumar Jha
Sandeep Kumar Jha
Non-communicable diseases such as diabetes and chronic kidney disease (CKD) are major global health concerns due to associated high morbidity rates. Conventional monitoring of these diseases typically involves invasive methods, which can be painful and inconvenient for patients. This study highlights the development of a non-invasive, handheld optical biosensor capable of multivariate analysis using saliva samples. The device used two distinct paper-fluidic strips designed with different enzyme–dye combinations to detect glucose and urea. The biosensor also used ambient temperature compensation to address the differential sensitivity of these sensors owing to variations caused by temperature-dependent enzyme kinetics, thereby enhancing the measurement accuracy. Biosensor characteristics with the glucose oxidase-based strip showed a sensitivity of 1.93 count per mg per dL, linearity range from 8 to 358 mg dL−1, limit of detection (LOD) of 8 mg dL−1, and response time of 7.35 s. The clinical validation shows good correlation between saliva glucose levels (SGLs) and blood glucose levels (BGLs). The urea biosensor strip shows a sensitivity of 1.51 count per mg per dL, LOD of 5 mg dL−1, linearity range from 5 to 90 mg dL−1, and response time of 3 s. The clinical validation for the CKD patient shows a significant correlation between blood urea levels and saliva urea levels. The results demonstrate that the device offers a rapid, reliable, and user-friendly alternative for point-of-care testing (POCT), potentially improving patient compliance and management of diabetes and CKD. Significance: The findings suggest that this technology could represent a significant advancement in non-invasive diagnostic tools and can be used as a POCT by chronic patients.