Charles L. Truwit

Charles L. Truwit

Auto-generated profile, based on publicly available information

Charles L. Truwit

From the Department of Radiology, University of Minnesota-Fairview and Hennepin County Medical Centers, Minneapolis, Minnesota

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2001 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
CTCharles L. Truwit
Charles L. Truwit
HLHaiying Liu
Haiying Liu
Purpose: To describe prospective stereotaxy, a novel method of trajectory alignment that works in real‐time. Materials and Methods: Prospective stereotaxy was used in minimally‐invasive neurosurgical procedures in 74 patients since February 1999. This methodology differs from framed and frameless stereotaxy, both of which are based on retrospective data. Rather, prospective stereotaxy uses real‐time MR images to align a surgical trajectory. Results: Phantom tests and clinical procedures in all patients were successfully performed using prospective stereotaxy. In all cases, surgical targets were accessed, and the diagnostic yield of neurobiopsy using prospective stereotaxy was 100%. Conclusion: Prospective stereotaxy is applicable to all cross‐sectional imaging, and is particularly useful for MR‐ and CT‐guided interventions. The method is simple, reproducible, and accurate in surgical targeting for neurobiopsy and electrode placement. It does not require cumbersome stereotactic frames or expensive optical detectors, and it offers immediate entry into the field of interventional MR with cylindrical MR scanners. J. Magn. Reson. Imaging 2001;13:452–457.


1 March 2014 in European Journal of Radiology
Verified
Journal Article
Closed access
Sam PayabvashSam Payabvash
Sam Payabvash
AMAlexander M. McKinney
Alexander M. McKinney
ZMZeke J McKinney
Zeke J McKinney
CPChristopher S. Palmer
Christopher S. Palmer
CTCharles L. Truwit
Charles L. Truwit

1 April 2006 in Operative Neurosurgery
Verified
Journal Article
Closed access
CTCharles L. Truwit
Charles L. Truwit
WHWalter A. Hall
Walter A. Hall
Objective: Between 1997 and 2004, more than 700 neurosurgical procedures were performed in a 1.5-T magnetic resonance-guided therapy suite. During this period, the concept of high-field intraoperative magnetic resonance imaging (MRI) was validated, as was a new surgical guidance tool, the Navigus (Image-guided Neurologics, Melbourne, FL), and its methodology, prospective stereotaxy. Clinical protocols were refined to optimize surgical techniques. That implementation, the “Minnesota suite, ” has recently been revised, and a new suite with a 3-T MRI scanner has been developed. Methods: On the basis of experience at the initial 1.5-T suite, a new suite was designed to house a 3-T MRI scanner with wide surgical access at the rear of the scanner (opposite the patient couch). Use of electrocautery, a fiberoptic headlamp, a power drill, and MRI-compatible neurosurgical cutlery was anticipated by inclusion of waveguides and radiofrequency filter panels that penetrate the MRI suite's radiofrequency shield. An MRI-compatible head holder was adapted for use on the scanner table. A few items exhibiting limited ferromagnetism were used within the magnetic field, taking strict precautions. Results: During the initial procedures (all magnetic resonance-guided neurobiopsies), the new suite functioned as anticipated. Although metallic artifact related to titanium needles is more challenging at 3 T than at 1.5 T, it can be contained even at 3 T. Similar to 1.5 T, such artifact is best contained when the device is oriented along B0, the main magnetic field. Surgical needles, disposable scalpels, and disposable razors, despite being minimally ferromagnetic, were easily controlled by the surgeon. Conclusion: An intraoperative magnetic resonance-guided neurosurgical theater has been developed with a 3-T MRI scanner. Intraoperative imaging is feasible at this field strength, and concerns regarding specific absorption rate can be allayed. Infection control procedures can be designed to permit neurosurgery within this environment. Despite the increase in magnetic field strength, safety can be maintained.

6 December 2012 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
BSB. Sarikaya
B. Sarikaya
AMA.M. McKinney
A.M. McKinney
BSB. Spilseth
B. Spilseth
CTC.L. Truwit
C.L. Truwit
SUMMARY: Term-equivalent imaging can assess myelination status in very preterm infants (<30 weeks' gestational age at birth). However, myelination assessment has yet to be compared among GRE-T1WI, SE-T1WI, and SE-T2WI at 3T. We aimed to compare the rates of myelination among those 3 sequences in 11 very preterm neonates who underwent 3T MR imaging at term-equivalent age and subsequently had normal neurologic development. On each sequence, 2 neuroradiologists individually assessed 22 structures. SE-T2WI depicted a higher myelination rate (present in 58.2%–66.4% of all structures) than either GRE-T1WI (51.6%–63.9%) or SE-T1WI (20.5%–38.5%), while GRE-T1WI had the highest interobserver agreement (κ, 0.56; P < .0001). Myelination was present in 90%–100% of patients within the corpus callosum splenium, DSCP, ICP, lateral lemniscus, and spinal tract/nucleus of cranial nerve V on SE-T2WI, and in the DSCP, ICP, lateral lemniscus, medial lemniscus, pyramidal decussation, PLIC, and superior cerebellar peduncle on GRE-T1WI, occurring in similar structures as previously shown at 1.5T and 1T. However, it is not clear whether these findings represent true myelination versus precursors to myelination.

11 September 2014 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
ATA.E. Tyan
A.E. Tyan
AMA.M. McKinney
A.M. McKinney
THT.J. Hanson
T.J. Hanson
CTC.L. Truwit
C.L. Truwit
SUMMARY: A prior clinical report of 3T MR imaging in subsequently healthy very premature neonates imaged at term-equivalent age found that both gradient recalled-echo–T1WI and spin-echo–T2WI showed higher rates of myelinated structures, compared with spin-echo–T1WI. The current study set out to assess those rates on the same sequences at 3T in term neonates and thus consisted of 16 term neonates with normal-appearing MR imaging findings who subsequently had normal findings at clinical follow-up. Two neuroradiologists independently assessed 19 structures in those infants on all 3 sequences. Gradient recalled-echo–T1WI showed a slightly higher rate of myelination (57.2%–72.4% of all structures) and interobserver agreement (κ = 0.546, P < .0001) than spin-echo–T2WI (58.2%–64.8%; κ = 0.468, P < .0001), while spin-echo–T1WI had the lowest myelination rate and agreement (25.0%–48.4%; κ = 0.384, P < .0001). Both observers noted that the following structures were myelinated in 88%–100% of patients on gradient recalled-echo–T1WI: the brachium of the inferior colliculus, decussation of the superior cerebellar peduncle, habenular commissure, medial lemniscus, pyramidal decussation, posterior limb of the internal capsule, and superior cerebellar peduncle; on spin-echo–T2WI, there was myelination in 88%–100% of the following structures: the brachium of the inferior colliculus, decussation of the superior cerebellar peduncle, inferior cerebellar peduncle, medial lemniscus, and posterior limb of the internal capsule. In conclusion, this study confirmed that similar to the findings in term-equivalent-age premature infants, myelination changes in term neonates may be best assessed on both gradient recalled-echo–T1WI and spin-echo–T2WI at 3T, and not on spin-echo–T1WI.