Considering the widespread use of proton exchange membrane (PEM) fuel cells, end-of-life management is critical. The main component of PEM fuel cells is the membrane electrode assembly (MEA), comprising a Nafion membrane sandwiched between two electrodes. The electrodes are made of platinum supported on carbon (Pt/C) and held together by the Nafion binder. Researchers have mainly focused on the recovery of platinum from the MEA. The low concentration of platinum in the electrodes makes thermal decomposition of the fluorinated polymeric binder, followed by a hydrometallurgy step being the most practical way to liberate and concentrate the platinum catalyst. In this manuscript, we show the use of aqueous ethanol and isopropyl alcohol to swell the PEM and recover it intact. The solvent mixture containing the electrodes is then subjected to microwave heating to dissolve the Nafion binder and liberate the Pt/C which can be further enhanced with induced mixing. This approach offers the potential for MEA short loop recycling. The proposed approach concentrates 87% of the platinum catalyst while being able to produce clean Nafion membrane. Finally, we show that the recycled gas diffusion layer can be re-used to create a new MEA with a slight decrease in performance.
The built environment is responsible for 40% of global energy demand, and, in line with urbanisation and population growth, this demand is expected to increase steadily. Urban areas are mostly composed of materials that can absorb energy from solar radiation and dissipate the accumulated energy in the form of heat. This study integrates a UAV-based Zenmuse XT S IR camera and handheld FLIR C5 thermal camera with ENVI-met microclimate simulation, providing quantitative insights for sustainable urban planning. From the 24 h experiment results, the characteristics of building surface materials are profiled for lowering energy use for internal thermal control during the operation stage of buildings. This study shows that building surface materials with the lowest solar reflectance and highest specific heat capacity reached a peak surface temperature of 73.5 °C in Jakarta (tropical hot climate) and 44.3 °C in Xiamen (subtropical late winter climate). In contrast, materials with the highest solar reflectance and lowest specific heat only reach a peak surface temperature of 58.1 °C in Jakarta and 27.9 °C in Xiamen. The peak surface temperature occurs at 2 PM in the afternoon. Moreover, we demonstrate the capability of an infrared drone to identify the peak surface temperatures of 55.8 °C at 2 PM in the study area in Xiamen. In addition, the ENVI-met validated model shows satisfactory correlation values of R > 0.9 and R2 > 0.8. This result demonstrates UAV-IR and ENVI-met simulation integration as a scalable method for city-level UHI diagnostics and monitoring.