9 June 2026 in Journal of Innovative Optical Health Sciences
Non-alcoholic fatty liver disease (NAFLD) is one of the most prevalent chronic liver diseases globally. Hepatic steatosis, characterized by the accumulation of lipid droplets (LDs), is a hallmark of NAFLD. Traditional pathology and specific fluorescent dye imaging have difficulty in observing LDs in their natural state within hepatocytes rapidly. In this study, a customized dynamic full-field optical coherence tomography (D-FFOCT) system was applied for label-free visualization of LDs and rapid ex vivo assessment of NAFLD. Two groups of mice fed the methionine choline-deficient (MCD) diet for one week and two weeks, respectively, underwent dual-mode FF-OCT imaging and comparative quantitative analysis. The subcellular structures—including nuclei and small LDs—were clearly observed. Quantitative analysis of D-FFOCT results revealed significant quantitative profiles in LD characteristics across various NAFLD stages. Furthermore, imaging of a non-alcoholic steatohepatitis (NASH) mouse model fed a high-fat diet for 14 weeks provided insights into the identification of inflammatory cells via D-FFOCT. These results indicate that D-FFOCT can effectively resolve the subcellular structure and quantify LDs in NAFLD models across varying severities, thereby demonstrating its potential for rapid NAFLD assessment and pharmaceutical development applications.
24 August 2026 in Journal of Innovative Optical Health Sciences
Imaging flow cytometry is rapidly developing toward higher spatial resolution and enhanced capability for resolving subcellular structures, which makes such systems increasingly dependent on high-numerical-aperture objectives for higher-resolution imaging, thereby imposing higher requirements on the stability of three-dimensional hydrodynamic focusing, the quality of optical interfaces, and the structural compatibility of microfluidic chips. In this work, we propose a low-cost fabrication method for glass microfluidic chips for imaging flow cytometry, based on laser processing and a two-step thermocompression bonding strategy. By separating microchannel pre-bonding from overall encapsulation, this method preserves the structural integrity of the microchannels while constructing an optical observation window compatible with high-numerical-aperture objectives, thereby meeting the adaptation requirements of mainstream microscope objectives in terms of working distance and mechanical interfacing. Experimental results show that the optical detection region of the fabricated chip exhibits nanoscale surface quality and good optical transmission performance. Flow imaging experiments further demonstrate that the chip achieved stable three-dimensional hydrodynamic focusing and high-quality fluorescence imaging under high-speed flow conditions, and that the resulting signals exhibited a narrow distribution with low fluctuation, indicating good detection stability and imaging reliability. The study shows that the proposed two-step thermocompression bonding process achieves a balance among the optical performance, structural integrity, and manufacturability of glass microfluidic chips, providing a feasible solution for the fabrication of high-throughput, low-cost, and biosafe chips for imaging flow cytometry.
1 October 2024 in Review of Scientific Instruments
Compensating for the pitch error in the scanning movement is a fundamental issue when conducting large-scale surface shape measurements with deflectometric profilers. This paper presents a new long trace profiler employing a shearing measurement technique. In this setup, the optical head and the mirror under test are mounted on two independent parallel movable air-bearing carriages to enable shearing and scanning movements separately. The distance between the optical head and the tested mirror remains fixed, effectively minimizing the influence of system errors resulting from imperfections in optical devices. Simulation studies show that the double shear measurement method with a low-spatial-frequency filtering process can effectively mitigate high-frequency angular measurement errors introduced by the instability of the air-bearing stage. Experimental tests conducted on flat mirrors demonstrated a precision of less than 50 nrad rms, thereby confirming the robustness of the system.