Neeraj Kumar Sharma

Neeraj Kumar Sharma

Auto-generated profile, based on publicly available information

Neeraj Kumar Sharma

Department of Electrical Engineering, Indian Institute of Technology Kanpur, Kanpur, India

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2015
Verified
Conference Paper
Closed access
NSNeeraj Kumar Sharma
Neeraj Kumar Sharma
SCSaikat Chakrabarti
Saikat Chakrabarti
Topology processing is a vital function of a power system state estimator. Detection, identification, and processing of the topology error are pre-requisites for successful execution of the state estimator. The conventional measurement residual based topology error processing methods may fail under certain measurement configurations and system topologies. This paper proposes an optimization based technique for topology error detection of power systems in presence of hybrid measurements. The proposed technique is successfully implemented on a number of test systems.

1 October 2015
Verified
Conference Paper
Closed access
NSNeeraj Kumar Sharma
Neeraj Kumar Sharma
SCSaikat Chakrabarti
Saikat Chakrabarti
BJBenjamin Jeyasurya
Benjamin Jeyasurya
Phasor measurement units (PMUs) are increasingly being used in modern power systems due to their high reporting rate and accuracy. The majority of the measurement devices in the existing power systems, however, are conventional asynchronous measurements. State-of-the-art state estimation algorithms are therefore required to include the hybrid set of measurements. Observability of the system with the given set of measurements is a pre-requisite of any state estimator. This paper proposes a numerical algorithm for observability analysis of power systems having hybrid measurements. The proposed method is demonstrated with the help of a number of test systems.

29 August 2025 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
NSNeeraj Kumar Sharma
Neeraj Kumar Sharma
SCSaikat Chakrabarti
Saikat Chakrabarti
ASAnkush Sharma
Ankush Sharma
Power distribution systems require three-phase state estimation due to their inherently unbalanced nature. Identifying a balanced reference bus is essential for conducting three-phase state estimation. However, such a reference bus is rarely available in distribution systems. Existing distribution system state estimation (DSSE) methodologies often randomly select a bus for this purpose, leading to biased results, while those based on a single angular reference face convergence issues. To address these challenges, this article introduces a novel method designed to mitigate the limitations associated with the reference bus in DSSE. This method is executed in two stages: first, it obtains the exact phase angles of the reference bus using local measurements available at that bus; second, it utilizes these precise phase angles to estimate the states of the distribution system. The efficacy of the proposed method is demonstrated through validation on the IEEE 13-node feeder, IEEE 37-node feeder, and IEEE 123-node feeder.

1 January 2025 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
NSNeeraj Kumar Sharma
Neeraj Kumar Sharma
SCSaikat Chakrabarti
Saikat Chakrabarti
ASAnkush Sharma
Ankush Sharma
This paper introduces a coordinated state estimation (CSE) approach designed to achieve a unique reference solution for both transmission and distribution systems. The CSE framework additionally addresses the challenges related to balanced bus requirements within distribution system state estimation (DSSE). Specifically, the CSE method models a transmission boundary bus as a reference bus for the execution of DSSE. Furthermore, the methodology constructs a consistency check vector based on the estimated variables of the modelled reference bus, thereby ensuring the coherence of the solution for the entire power system. To manage the substantial complexity of the problem, the CSE approach employs a parallel estimation strategy. This paper validates the CSE technique through a comprehensive analysis of different power transmission and distribution system combinations. The study focuses on the IEEE 14‐bus and New England 39‐bus systems as transmission networks, alongside the IEEE 13‐node and 37‐node feeders as distribution networks. Validation is conducted using MATLAB and DIgSILENT PowerFactory software tools.

26 August 2026 in Electric Power Systems Research
Verified
Journal Article
Closed access
NSNeeraj Kumar Sharma
Neeraj Kumar Sharma
SCSaikat Chakrabarti
Saikat Chakrabarti
ASAnkush Sharma
Ankush Sharma

1 October 2026 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
NSNeeraj Kumar Sharma
Neeraj Kumar Sharma
SCSaikat Chakrabarti
Saikat Chakrabarti
ASAnkush Sharma
Ankush Sharma
Dynamic thermal line rating (DTLR) enhances the power transfer capability of thermally limited overhead lines by accounting for real-time environmental and operational conditions. Key influencing factors include solar irradiance, ambient temperature, line current, wind velocity (wind speed with angular direction), and conductor temperature. While some parameters are readily available via online sources or existing sensors, accurate DTLR estimation typically requires wind and conductor temperature data, which often demand additional instrumentation and cost. This paper proposes a cost-effective methodology for short transmission lines that eliminates the need for direct wind and conductor temperature measurements. Instead, it estimates the real-time line resistance using data from emulated SCADA or PMU systems, from which the conductor temperature is subsequently estimated. Using this, along with accessible environmental data, the method estimates wind velocity effects and estimates an optimal DTLR. This method is well suited for regions exhibiting relatively uniform weather conditions, particularly flat terrains. Validation is performed using IEEE Standard 738-2012, with DIgSILENT PowerFactory used to emulate real-time data from SCADA and PMU, and DTLR estimation simulated in MATLAB.