Atul Singh Minhas

Atul Singh Minhas

Auto-generated profile, based on publicly available information

Atul Singh Minhas

Macquarie University

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2009 in Physiological Measurement
Verified
Journal Article
Closed access
KJKiwan Jeon
Kiwan Jeon
AMAtul S Minhas
Atul S Minhas
YKYoung Tae Kim
Young Tae Kim
WJWoo Chul Jeong
Woo Chul Jeong
HKHyung Joong Kim
Hyung Joong Kim
EWEung Je Woo
Eung Je Woo
Magnetic resonance electrical impedance tomography (MREIT) is a new bio-imaging modality providing cross-sectional conductivity images from measurements of internal magnetic flux densities produced by externally injected currents. Recent experimental results of postmortem and in vivo imaging of the canine brain demonstrated its feasibility by showing conductivity images with meaningful contrast among different brain tissues. MREIT image reconstructions involve a series of data processing steps such as k-space data handling, phase unwrapping, image segmentation, meshing, modelling, finite element computation, denoising and so on. To facilitate experimental studies, we need a software tool that automates these data processing steps. In this paper, we summarize such an MREIT software package called CoReHA (conductivity reconstructor using harmonic algorithms). Performing imaging experiments of the postmortem canine abdomen, we demonstrate how CoReHA can be utilized in MREIT. The abdomen with a relatively large field of view and various organs imposes new technical challenges when it is chosen as an imaging domain. Summarizing a few improvements in the experimental MREIT technique, we report our first conductivity images of the postmortem canine abdomen. Illustrating reconstructed conductivity images, we discuss how they discern different organs including the kidney, spleen, stomach and small intestine. We elaborate, as an example, that conductivity images of the kidney show clear contrast among cortex, internal medulla, renal pelvis and urethra. We end this paper with a brief discussion on future work using different animal models.

23 April 2022
Verified
Book Chapter
Closed access
PDF file
AMAtul Singh Minhas
Atul Singh Minhas
RORuth Oliver
Ruth Oliver

25 March 2011 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
AMAtul S. Minhas
Atul S. Minhas
WJWoo Chul Jeong
Woo Chul Jeong
YKYoung Tae Kim
Young Tae Kim
YHYeqing Han
Yeqing Han
HKHyung Joong Kim
Hyung Joong Kim
EWEung Je Woo
Eung Je Woo
Latest experimental results in magnetic resonance electrical impedance tomography (MREIT) demonstrated high-resolution in vivo conductivity imaging of animal and human subjects using imaging currents of 5 to 9 mA. Externally injected imaging currents induce magnetic flux density distributions, which are affected by a conductivity distribution. Since we extract the induced magnetic flux density images from MR phase images, it is essential to reduce noise in the phase images. In vivo human and disease model animal experiments require reduction of imaging current amplitudes and scan times. In this article, we investigate a multi-echo based MREIT pulse sequence where we utilize a remaining time after the first echo within one TR to obtain more echo signals. It also allows us to prolong the total current injection time. From phantom and animal imaging experiments, we found that this method significantly reduces the noise level in measured magnetic flux density images. We describe experimental validation of the multi-echo sequence by comparing its performance with a single-echo method using 3 mA imaging currents. The proposed method will be advantageous for an imaging region with long T2 values such as the brain and knee. Depending on T2 values, we suggest using two or three echoes in future experimental studies. Magn Reson Med, 2011.

2 February 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
CLClémentine Lesbats
Clémentine Lesbats
NKNitish Katoch
Nitish Katoch
AMAtul Singh Minhas
Atul Singh Minhas
ATArthur Taylor
Arthur Taylor
HKHyung Joong Kim
Hyung Joong Kim
HPHarish Poptani
Harish Poptani
Purpose: To establish high‐frequency magnetic resonance electrical properties tomography (MREPT) as a novel contrast mechanism for the assessment of glioblastomas using a rat brain tumor model.Methods: Six F98 intracranial tumor bearing rats were imaged longitudinally 8, 11 and 14 days after tumor cell inoculation. Conductivity and mean diffusivity maps were generated using MREPT and Diffusion Tensor Imaging. These maps were co‐registered with T2‐weighted images and volumes of interests (VOIs) were segmented from the normal brain, ventricles, edema, viable tumor, tumor rim, and tumor core regions. Longitudinal changes in conductivity and mean diffusivity (MD) values were compared in these regions. A correlation analysis was also performed between conductivity and mean diffusivity values.Results: The conductivity of ventricles, edematous area and tumor regions (tumor rim, viable tumor, tumor core) was significantly higher (P < .01) compared to the contralateral cortex. The conductivity of the tumor increased over time while MD from the tumor did not change. A marginal positive correlation was noted between conductivity and MD values for tumor rim and viable tumor, whereas this correlation was negative for the tumor core.Conclusion: We demonstrate a novel contrast mechanism based on ionic concentration and mobility, which may aid in providing complementary information to water diffusion in probing the microenvironment of brain tumors.

16 March 2011 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
Tong In OhTong In Oh
Tong In Oh
YKYoung Tae Kim
Young Tae Kim
AMAtul Minhas
Atul Minhas
JSJin Keun Seo
Jin Keun Seo
OKOh In Kwon
Oh In Kwon
EWEung Je Woo
Eung Je Woo
Magnetic resonance electrical impedance tomography (MREIT) aims to produce high-resolution cross-sectional images of conductivity distribution inside the human body. Injected current into an imaging object induces a distribution of internal magnetic flux density, which is measured by using an MRI scanner. We can reconstruct a conductivity image based on its relation with the measured magnetic flux density. In this paper, we explain the contrast mechanism in MREIT by performing and analyzing a series of numerical simulations and imaging experiments. We built a stable conductivity phantom including a hollow insulating cylinder with holes. Filling both inside and outside the hollow cylinder with the same saline, we controlled ion mobilities to create a conductivity contrast without being affected by the ion diffusion process. From numerical simulations and imaging experiments, we found that slopes of induced magnetic flux densities change with hole diameters and therefore conductivity contrasts. Associating the hole diameter with apparent conductivity of the region inside the hollow cylinder with holes, we could experimentally validate the contrast mechanism in MREIT. Interpreting reconstructed apparent conductivity images of the phantom as ion mobility images, we discuss the meaning of the apparent conductivity seen by a certain probing method. In designing MREIT imaging experiments, the ion mobility imaging method using the proposed stable conductivity phantom will enable us to estimate a distinguishable conductivity contrast for a given set of imaging parameters.

1 July 2017
Verified
Conference Paper
Open access
PKPoonam Kumari
Poonam Kumari
MLMiguel López-Benítez
Miguel López-Benítez
Gyu Myoung LeeGyu Myoung Lee
Gyu Myoung Lee
TKTae-Seong Kim
Tae-Seong Kim
AMAtul S. Minhas
Atul S. Minhas
Wearable devices for human activity tracking have been emerging rapidly. Most of them are capable of sending health statistics to smartphones, smartwatches or smart bands. However, they only provide the data for individual analysis and their data is not integrated into clinical practice. Leveraging on the Internet of Things (IoT), edge and cloud computing technologies, we propose an architecture which is capable of providing cloud based clinical services using human activity data. Such services could supplement the shortage of staff in primary healthcare centers thereby reducing the burden on healthcare service providers. The enormous amount of data created from such services could also be utilized for planning future therapies by studying recovery cycles of existing patients. We provide a prototype based on our architecture and discuss its salient features. We also provide use cases of our system in personalized and home based healthcare services. We propose an International Telecommunication Union based standardization (ITU-T) for our design and discuss future directions in wearable IoT.