University of Applied Sciences Münster, Department of Chemical Engineering, Laboratory of Instrumental Analytics, Stegerwaldstraße 39, 48565 Steinfurt, Germany
Auto-generated profile, based on publicly available information
Stephanie Hanning
University of Applied Sciences Münster, Department of Chemical Engineering, Laboratory of Instrumental Analytics, Stegerwaldstraße 39, 48565 Steinfurt, Germany
The production of polymeric calibration standard materials with sufficient homogeneity for the calibration of analytical methods with high lateral resolution like LA-ICP-MS was investigated. An index η* was introduced to compare the homogeneities of different acrylonitrile butadiene styrene terpolymer (ABS) based samples. It was demonstrated, that elements present in organic compounds could be introduced into polymeric materials with a higher homogeneity than inorganic compounds without special treatment. For organic Br compounds, a 20 to 30 times higher value for η* was found than it was for the case of AgBr. For Pb stearate and Pb acetate, 10 times higher values for η* were found than was the case for PbCrO4. For PbO, it is shown that multiple extrusion and mechanical treatment can improve the homogeneity of certain inorganic compounds as particle sizes are decreased during the extrusion.
19 November 2009 in Journal of Analytical Atomic Spectrometry
In this study the microscopic homogeneity of the newly developed plastic reference materials BAM H001–BAM H010 was investigated. The materials consist of an acrylonitryle-butadien-styrene terpolymer, doped with different amounts of the elements Br, Cd, Cr, Hg and Pb. For the quantitative determination of the degree of homogeneity, a procedure proposed by Kempenaers et al. (Fresenius J. Anal. Chem., 2001, 369, 733–737) was used. On every sample an extensive number of different points were analyzed and standard deviation for every element mentioned above was used to calculate a minimal sampling mass that is necessary to reach a certain level of uncertainty caused by inhomogeneity (mmin,5%). The experiments were taken out with synchrotron µ-XRF (SR µ-XRF) at BESSYII in Berlin and by laser ablation inductively coupled plasma mass spectroscopy (LA-ICP-MS). The calculated values for mmin,5% of both techniques showed comparable results for all elements. It could be shown that the materials are suitable for calibration of micro analytic techniques if at least 64 µg are used.
3 March 2022 in Journal of Analytical Atomic Spectrometry
The C, H, N and O composition of polymers, sometimes called “dark matrix”, is determined by wavelength dispersive X-ray fluorescence (WDXRF). The recovery was best for the lowest spectral resolution and highest recorded intensity.