Darren Hight

Darren Hight

Auto-generated profile, based on publicly available information

Darren Hight

Department of Anesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2017 in British Journal of Anaesthesia
Verified
Journal Article
Closed access
PDF file
AGA.L. Gaskell
A.L. Gaskell
DHD.F. Hight
D.F. Hight
JWJ. Winders
J. Winders
GTG. Tran
G. Tran
ADA. Defresne
A. Defresne
RSR.D. Sanders
R.D. Sanders
The isolated forearm test (IFT) is the gold standard test of connected consciousness (awareness of the environment) during anaesthesia. The frontal alpha-delta EEG pattern (seen in slow wave sleep) is widely held to indicate anaesthetic-induced unconsciousness. A priori we proposed that one responder with the frontal alpha-delta EEG pattern would falsify this concept. Frontal EEG was recorded in a subset of patients from three centres participating in an international multicentre study of IFT responsiveness following tracheal intubation. Raw EEG waveforms were analysed for power–frequency spectra, depth-of-anaesthesia indices, permutation entropy, slow wave activity saturation and alpha-delta amplitude-phase coupling. Volitional responses to verbal command occurred in six out of 90 patients. Three responses occurred immediately following intubation in patients (from Sites 1 and 2) exhibiting an alpha-delta dominant (delta power >20 dB, alpha power >10 dB) EEG pattern. The power–frequency spectra obtained during these responses were similar to those of non-responders (P>0.05) at those sites. A further three responses occurred in (Site 3) patients not exhibiting the classic alpha-delta EEG pattern; these responses occurred later relative to intubation, and in patients had been co-administered ketamine and less volatile anaesthetic compared with Site 1 and 2 patients. None of the derived depth-of-anaesthesia indices could robustly discrimate IFT responders and non-responders. Connected consciousness can occur in the presence of the frontal alpha-delta EEG pattern during anaesthesia. Frontal EEG parameters do not readily discriminate volitional responsiveness (a marker of connected consciousness) and unresponsiveness during anaesthesia. NCT02248623

7 March 2023 in British Journal of Anaesthesia
Verified
Journal Article
Closed access
DHDarren Hight
Darren Hight
MKMatthias Kreuzer
Matthias Kreuzer
GUGesar Ugen
Gesar Ugen
PSPeter Schuller
Peter Schuller
FSFrank Stüber
Frank Stüber
HKHeiko A. Kaiser
Heiko A. Kaiser

29 May 2017 in Frontiers in Systems Neuroscience
Verified
Journal Article
Open access
DHDarren Hight
Darren Hight
LVLogan J. Voss
Logan J. Voss
PGPaul S. Garcia
Paul S. Garcia
JSJamie Sleigh
Jamie Sleigh
Oscillations in the electroencephalogram (EEG) at the alpha frequency (8 – 12 Hz) are thought to be ubiquitous during surgical anesthesia, but the details of how this oscillation responds to ongoing changes in volatile anesthetic concentration have not been well characterised. It is not known how often alpha oscillations are absent in the clinical context, how sensitively alpha frequency and power respond to changes in anesthetic concentration, and what effect increased age has on alpha frequency. Bipolar EEG was recorded frontally from 305 patients undergoing surgery with sevoflurane or desflurane providing general anesthesia. A new method of detecting the presence of alpha oscillations based on the stability of the rate of change of the peak frequency in the alpha range was developed. Linear concentration-response curves were fitted to assess the sensitivity of alpha power and frequency measures to changing levels of anesthesia. Alpha oscillations were seen to be inexplicably absent in around 4 % of patients. Maximal alpha power increased with increasing volatile anesthetic concentrations in half of the patients, and decreased in the remaining patients. Alpha frequency decreased with increasing anesthetic concentrations in near to 90% percent of patients. Increasing age was associated with decreased sensitivity to volatile anesthesia concentrations, and with decreased alpha frequency, which sometimes transitioned into the theta range (5 – 7 Hz). While peak alpha frequency shows a consistent slowing to increasing volatile concentrations, the peak power of the oscillation does not, suggesting that frequency might be more informative of depth of anesthesia than traditional power based measures during volatile-based anesthesia. The alpha oscillation becomes slower with increasing age, even when the decreased anesthetic needs of older patients were taken into account.

1 October 2018 in NeuroImage
Verified
Journal Article
Closed access
AHAxel Hutt
Axel Hutt
JLJérémie Lefebvre
Jérémie Lefebvre
DHDarren Hight
Darren Hight
JSJamie Sleigh
Jamie Sleigh

1 April 2018 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
ZLZhenhu Liang
Zhenhu Liang
CHCheng Huang
Cheng Huang
YLYongwang Li
Yongwang Li
DHDarren F Hight
Darren F Hight
LVLogan J Voss
Logan J Voss
Yang BaiYang Bai
Yang Bai
Objective : Significant spectral electroencephalogram (EEG) pattern characteristics exist in individual patients during the re-establishment of consciousness after general anesthesia. However, these EEG patterns cannot be quantitatively identified using commercially available depth of anesthesia (DoA) monitors. This study proposes an effective classification method and indices to classify these patterns among patients. Approach : Four types of emergence EEG patterns were identified based on the EEG data set from 52 patients undergoing sevoflurane general anesthesia from two hospitals. Then, the relative power spectrum density (RPSD) of five frequency sub-bands of clinical interest (delta, theta, alpha, beta and gamma) were selected for emergence state analysis. Finally, a genetic algorithm support vector machine (GA-SVM) was used to identify the emergence EEG patterns. The performance was reported in terms of sensitivity (SE), specificity (SP) and accuracy (AC). Main results : The combination of the mean and mode of RPSD in the delta and alpha band ( P (delta)/ P (alpha) performed the best in the GA-SVM classification. The AC indices obtained by GA-SVM across the four patterns were 90.64 ± 7.61, 81.79 ± 5.84, 82.14 ± 7.99 and 72.86 ± 11.11 respectively. Furthermore, the emergence time of the patients with EEG emergence patterns I and III increased as the patients’ age increased. However, for patients with EEG emergence pattern IV, the emergence time positively correlates with the patients’ age when they are under 50, and negatively correlates with it when they are over 50. Significance : The mean and mode of P (delta)/ P (alpha) is a useful index to classify the different emergence EEG patterns. In addition, these patterns may correlate with an underlying neural substrate which is related to the patients’ age. Highlights ► Four emergence EEG patterns were found in γ -amino-butyric acid (GABA)-ergic anesthetic drugs. ► A genetic algorithm combined with a support vector machine (GA-SVM) was proposed to identify the emergence EEG patterns. ► The relative power spectrum density (RPSD) was used as a feature to classify the emergence EEG patterns and good accuracy was achieved. ► The statistics shows that the emergence EEG patterns are age-related and may have value in assessing postoperative brain states.

16 June 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MHMeysam Hashemi
Meysam Hashemi
AHAxel Hutt
Axel Hutt
DHDarren Hight
Darren Hight
JSJamie Sleigh
Jamie Sleigh
In recent years, more and more surgeries under general anesthesia have been performed with the assistance of electroencephalogram (EEG) monitors. An increase in anesthetic concentration leads to characteristic changes in the power spectra of the EEG. Although tracking the anesthetic-induced changes in EEG rhythms can be employed to estimate the depth of anesthesia, their precise underlying mechanisms are still unknown. A prominent feature in the EEG of some patients is the emergence of a strong power peak in the β–frequency band, which moves to the α–frequency band while increasing the anesthetic concentration. This feature is called the beta-buzz. In the present study, we use a thalamo-cortical neural population feedback model to reproduce observed characteristic features in frontal EEG power obtained experimentally during propofol general anesthesia, such as this beta-buzz. First, we find that the spectral power peak in the α– and δ–frequency ranges depend on the decay rate constant of excitatory and inhibitory synapses, but the anesthetic action on synapses does not explain the beta-buzz. Moreover, considering the action of propofol on the transmission delay between cortex and thalamus, the model reveals that the beta-buzz may result from a prolongation of the transmission delay by increasing propofol concentration. A corresponding relationship between transmission delay and anesthetic blood concentration is derived. Finally, an analytical stability study demonstrates that increasing propofol concentration moves the systems resting state towards its stability threshold.