1 January 1997 in Aerosol Science and Technology
Alpha-ray radiolysis of SO2/H2O/N2 gas mixtures is carried out to investigate the competitive processes of ion-induced and binary homogeneous nucleation in this system. Charged particles in the system are indicative of ion-induced nucleation and most likely involve water clusters. Charged particle neutralization was prevented by application of a dc electric field, therefore, uncharged particles in the system result from homogeneous nucleation. Hydroxyl (OH) radicals are generated by the a-ray radiolysis. Oxidation of SO2 by OH radicals leads to sulfuric acid (H2SO4) vapor molecules and to subsequent binary homogeneous nucleation of H2SO4/H2O. At increased SO2 concentrations the contribution of binary homogeneous nucleation increases relative to that of ion-induced nucleation. Electrical mobility distributions of bipolar ions and nanometer-sized charged particles were measured with a cluster-differential mobility analyzer combined with a Faraday cup electrometer. In this system, ion-induced nucleation occurred preferentially on negative rather than positive ions.
1 January 1990 in Aerosol Science and Technology
The electrostatic size analysis of polydisperse aerosols using a differential mobility analyzer (DMA) has been studied from the following two standpoints: (1) the faster measurement of electrical mobility distribution, arid (2) the correction of particle loss by Brownian diffusion in the data inversion, fn electrical mobility measurements, the number of mobility channels in a scan of the full mobility range is decreased and the full electrical mobility distribution is estimated by interpolation with a spline fitting. The correction of the Brownian diffusive losses of particles in the DMA including a neutralizer are combined with the data inversion method in order to evaluate the size distribution of aerosols unaffected by the particle loss. The reliability of the corrected data inversion method is confirmed by the experiment, and the particle size distribution of an aerosol is determined within several minutes by means of a faster scanning technique.
1 April 2003 in Journal of Nanoparticle Research
1 September 2000 in Journal of Applied Physics
27 September 1999 in Applied Physics Letters
A chemical vapor deposition (CVD) method, called ionization CVD, in which ionized source molecules were deposited on a substrate by Coulombic force, was developed to control gas-phase reaction and film morphology. This method was applied to the tetraethylorthosilicate (TEOS)/ozone-atmospheric pressure chemical vapor deposition process by using the surface corona discharge. TEOS/O3 films deposited on SiN and SiO2 films by this CVD method showed good properties for the flow shape, the gap filling and the surface morphology. In Fourier-transform infrared spectra of gas-phase intermediates collected in the vapor condenser, the intensity of the absorption peak at 600 cm−1 was different between ionized intermediates and nonionized intermediates.
15 November 2008 in Materials Letters