Didarul Ahasan Redwan

Didarul Ahasan Redwan

Auto-generated profile, based on publicly available information

Didarul Ahasan Redwan

Department of Mechanical Engineering Bangladesh University of Engineering and Technology Dhaka Bangladesh

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

25 February 2021 in Physical Chemistry Chemical Physics
Verified
Journal Article
Closed access
PDF file
HRHabibur Rahman
Habibur Rahman
ECEmdadul Haque Chowdhury
Emdadul Haque Chowdhury
DRDidarul Ahasan Redwan
Didarul Ahasan Redwan
SMShailee Mitra
Shailee Mitra
Sungwook HongSungwook Hong
Sungwook Hong
Stanene could be integrated with other 2D nanomaterials such as graphene, hBN, and SiC in the form of vertical heterostructures to improve mechanical strength.

29 January 2021 in Heat Transfer
Verified
Journal Article
Closed access
PDF file
HPHasib A. Prince
Hasib A. Prince
EREnamul H. Rozin
Enamul H. Rozin
ECEmdadul H. Chowdhury
Emdadul H. Chowdhury
DRDidarul A. Redwan
Didarul A. Redwan
MMMohammad A. H. Mamun
Mohammad A. H. Mamun

1 January 2021 in Energy Engineering
Verified
Journal Article
Open access
SHSheikh Hassan
Sheikh Hassan
DRDidarul Ahasan Redwan
Didarul Ahasan Redwan
Md Mamun MollaMd Mamun Molla
Md Mamun Molla
STSharaban Thohura
Sharaban Thohura
MTMd Abu Taher
Md Abu Taher
SSSadia Siddiqa
Sadia Siddiqa
A two-dimensional (2D) laminar flow of nanofluids confined within a square cavity having localized heat source at the bottom wall has been investigated. The governing Navier–Stokes and energy equations have been non dimensionalized using the appropriate non dimensional variables and then numerically solved using finite volume method. The flow was controlled by a range of parameters such as Rayleigh number, length of heat source and nanoparticle volume fraction. The numerical results are represented in terms of isotherms, streamlines, velocity and temperature distribution as well as the local and average rate of heat transfer. A comparative study has been conducted for two different base fluids, ethylene glycol and water as well as for two different solids and . It is found that the ethylene glycol-based nanofluid is superior to the water-based nanofluid for heat transfer enhancement.

28 November 2020
Verified
Conference Paper
Closed access
HRHabibur Rahman
Habibur Rahman
SMShailee Mitra
Shailee Mitra
DRDidarul Ahasan Redwan
Didarul Ahasan Redwan
2D nanomaterials such as graphene, silicene, germanene and stanene are considered as one of the emerging research materials for transistor scaling. These materials have potential application in electronic, semiconductor and optoelectronic devices. In this present investigation, we have used the nearest neighbor tight-binding approach (NNTB) to explore the electronic band structure of these analogous 2D nanomaterials. It has been found that a 1.91 eV, 0.79eV, 0.S0eV and 0.60 eV bandgap can be successfully extracted from 4AGNR, 4ASiNR, 4AGeNR and 4ASnNR respectively. The extracted bandgap from 25AGNR, 25SiNR, 25GeNR and 25SnNR is calculated as 0.35 eV, 0.15eV, 0.15eV and 0.11 eV respectively. We have confirmed that for useful application of these nanomaterials in the semiconductor device, we have to keep the dimension of the nanodevices as small as possible. Besides, it has been found that at lower scale these nanomaterials exhibit direct bandgap which is useful for optoelectronic devices. We have demonstrated that as the width of nanoribbon increases that is device size, the possibility for extracting suitable bandgap for semiconductor devices reduces. Our computational approach suggests that as the ribbon width increases these nanomaterials behave like a conductor. Variation of extracted bandgap as a function of the device is also depicted. Our simulation results also suggest that extracted bandgap can be classified into three families of category. 3p and 3p+1 are suitable for semiconducting application whereas 3p+2 family is suitable for the semi-metallic application. These results may help to design and scale graphene, silicene, germanene and stanene based semiconductor devices.

16 November 2020
Verified
Conference Paper
Closed access
PDF file
HRHabibur Rahman
Habibur Rahman
ECEmdadul Haque Chowdhury
Emdadul Haque Chowdhury
DRDidarul Ahasan Redwan
Didarul Ahasan Redwan
HPHasib Ahmed Prince
Hasib Ahmed Prince
MAM. Ruhul Amin
M. Ruhul Amin
The current work aims to investigate the thermo-hydraulic performances of a dynamic wall heat exchanger by varying amplitude and frequency of the oscillating waveform. The lower wall of the channel is exposed to constant heat flux, the upper insulating wall is deforming in a sinusoidal waveform, and water is taken as the working fluid. The governing partial differential equations are solved by using the Arbitrary Lagrangian-Eulerian finite element method. The study has been performed in the transient regime for up to 1.0 second. At first the effects of frequency variation over the average mass flow rate, convective heat transfer coefficient, and the average liquid temperature have been observed for a particular amplitude of the dynamic wall. It has been found that the mass flow rate of water increases linearly with increasing frequency. Convective heat transfer coefficient decreases with increasing frequency up to 50 Hz, then starts to increase notably. Interestingly, the fluctuating average liquid temperature decreases and reaches a steady-state faster with increasing frequency. To explore the effect of amplitude over heat transfer characteristics, the amplitude ratio of the sinusoidal wave is varied maintaining a constant frequency of oscillation. It has been observed that with increasing amplitude, both mass flow rate and convective heat transfer coefficient increase exponentially. Increasing amplitude ratio from 0.5 to 0.9 results in an increment in the convective heat transfer coefficient by about 5 times. Although, the average liquid temperature decreases and reaches a steady state faster with increasing amplitude, initially the peak temperature of the water is recorded for the highest amplitude.