Alexia K. Cash

Alexia K. Cash

Auto-generated profile, based on publicly available information

Alexia K. Cash

Lampe Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2025 in Cancers
Verified
Journal Article
Open access
PDF file
JFJordan Fong
Jordan Fong
LRLogan Reeg
Logan Reeg
JDJewels Darrow
Jewels Darrow
RWRobert Williamson
Robert Williamson
ARAnna Riordan
Anna Riordan
MSMichael B. Sano
Michael B. Sano
Objectives: There is a critical need for effective focal therapies for patients with inoperable or anatomically complex tumors where conventional ablation techniques pose high risk or are ineffective. Integrated Nanosecond Pulsed Irreversible Electroporation (INSPIRE) is a novel non-thermal ablation modality which uses real time temperature feedback during pulse delivery to safely treat tumors near critical structures. This study evaluated the impact of exposed electrode length on ablation zone size, reproducibility, and cardiac safety in a large animal model. Methods: INSPIRE treatments were performed in an in vivo healthy porcine liver model. All treatments administered 6000 V 1000 ns pulses with a 45 °C temperature set point. Treatments were administered percutaneously via an electrode and grounding pad approach using an internally cooled electrode applicator. The exposed electrode region at the distal end of the applicator was set to either 0.5, 1.0, 1.5, or 2.0 cm. Ablation zones were assessed via ultrasound, contrast-enhanced CT, and gross pathology one week post-treatment. Cardiac safety was evaluated by measuring pre- and post-treatment serum Troponin levels. Results: All treatments were completed without adverse events. Troponin levels remained stable (pre: 0.249 ng/mL; post: 0.224 ng/mL), indicating no measurable cardiac injury. The 1.5 cm exposure length produced the largest and most consistent ablation volumes, with a mean volume of 12.8 ± 2.6 cm3 and average dimensions of 3.7 × 2.7 cm in under 6 min. Increasing exposure length beyond 1.5 cm introduced greater variability and reduced treatment volumes. Conclusions: INSPIRE enables safe, large-volume, single-applicator ablation without a need for electrical pulse synchronization with R wave in cardiac rhythm. The 1.5 cm exposure length offers optimal balance between energy delivery and treatment consistency. These findings support further clinical investigation of INSPIRE for non-thermal ablation of inoperable tumors.

19 August 2025 in Journal of Visualized Experiments
Verified
Journal Article
Closed access
PDF file
RWRobert Williamson
Robert Williamson
ACAlexia K. Cash
Alexia K. Cash
ARAnna E. Riordan
Anna E. Riordan
MSMichael B. Sano
Michael B. Sano
Electroporation is a promising technology utilizing electrical pulses for macromolecule delivery and soft-tissue ablation, with applications that include next-generation prophylactics and the treatment of genetic diseases such as cancer. This study demonstrates a high-throughput capable 3D tissue culture model for quantification of the reversible and irreversible electroporation thresholds for a given electroporation protocol. By using a non-uniform electric field and analyzing the spatial distribution of transfected cells, both reversible and irreversible thresholds can be identified within a single sample, increasing the efficiency at which electroporation protocols can be characterized, especially for in vivo translation. To show this capability, 3D tissue mimics containing HEK293 cells were transfected using a ring and pin electrode to deliver a GFP-encoding plasmid. Electroporation thresholds were then derived based on fluorescent microscopy images of the transfected samples. This model demonstrates potential for use as a means for high-throughput evaluation of electroporation protocols, a key advantage over current methods to evaluate these thresholds, which tend to be time-intensive and are less representative of in vivo conditions.

19 August 2025
Verified
Dataset
Closed access
PDF file
RWRobert Williamson
Robert Williamson
ACAlexia K. Cash
Alexia K. Cash
ARAnna E. Riordan
Anna E. Riordan
MSMichael B. Sano
Michael B. Sano
Electroporation is a promising technology utilizing electrical pulses for macromolecule delivery and soft-tissue ablation, with applications that include next-generation prophylactics and the treatment of genetic diseases such as cancer. This study demonstrates a high-throughput capable 3D tissue culture model for quantification of the reversible and irreversible electroporation thresholds for a given electroporation protocol. By using a non-uniform electric field and analyzing the spatial distribution of transfected cells, both reversible and irreversible thresholds can be identified within a single sample, increasing the efficiency at which electroporation protocols can be characterized, especially for in vivo translation. To show this capability, 3D tissue mimics containing HEK293 cells were transfected using a ring and pin electrode to deliver a GFP-encoding plasmid. Electroporation thresholds were then derived based on fluorescent microscopy images of the transfected samples. This model demonstrates potential for use as a means for high-throughput evaluation of electroporation protocols, a key advantage over current methods to evaluate these thresholds, which tend to be time-intensive and are less representative of in vivo conditions.

8 April 2026 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
ACAlexia K. Cash
Alexia K. Cash
RWRobert H. Williamson
Robert H. Williamson
DEDriss Elhanafi
Driss Elhanafi
MSMichael B. Sano
Michael B. Sano
Purpose: To determine if GET via charge-balanced patterned bipolar microsecond pulses could be improved, novel bursts of patterned bipolar microsecond pulsed electric fields were investigated in a cuvette and 3D tissue model to evaluate gene electrotransfer (GET) in vitro. Methods: Various charge-balancing strategies were implemented to create bipolar microsecond waveforms. A cuvette model was used to identify optimal electric field intensities and plasmid concentrations for each protocol before cotransfection of two plasmids was evaluated in a cuvette and a 3D tissue model for a subset of best-performing protocols. Results: The 2-1-1 unbalanced, 1-1-0.5 unbalanced, and 2-1-1 burst-balanced protocols were the top bipolar microsecond protocols tested on HEK 293 cells and achieved GET efficiencies comparable to the top-performing 8x100μs conventional GET protocol. Of the patterned bipolar pulses, the highest performing was 2-1-1 Unbalanced at 1000 V/cm with a dose of 5 ms, a delivery rate of 200 μs/s, and a plasmid concentration of 1250 µg/mL. C28 chondrocytes were also tested via the cuvette model with 2-1-1 burst-balanced exceeding even the top-performing 8x100μs conventional protocol in GET efficiency. Conclusion: Patterned bipolar microsecond GET tested in this study has similar transfection capabilities as conventional GET settings while maintaining viability and requiring lower plasmid concentration for similar results. The novel patterned waveforms tested potentially enhance electrophoretic effects, reducing the need for high plasmid concentrations in vivo. These waveforms were developed based on < 2 μs bipolar pulses (H-FIRE and INSPIRE) which have been shown to reduce muscle stimulations in vivo.

31 October 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
ACAlexia Cash
Alexia Cash
HFHunter Fitzpatrick
Hunter Fitzpatrick
GGGabriel Alejandro Garibaldi
Gabriel Alejandro Garibaldi
AFAnjelyka Fasci
Anjelyka Fasci
MLMaria J. Londono
Maria J. Londono
GSGongchen Sun
Gongchen Sun
Electroporation, a biophysical method that transiently permeabilizes cell membranes via externally applied electric pulses, has evolved from bulk, low-resolution approaches to highly controlled micro- and nano-electroporation (MEP/NEP) platforms. By inducing a transmembrane potential exceeding a critical threshold (≈0.5–1.5 V), nanoscale pores form, enabling delivery of nucleic acids, proteins, drugs, and probes without viral vectors or chemical carriers. Early work demonstrated efficient plasmid uptake in mouse lyoma cells using high-intensity, short-duration pulses, establishing the foundation for modern gene transfer applications. Contemporary MEP devices improve spatial and temporal field control, reducing voltage requirements and cellular damage, while NEP systems focus the electric field onto subcellular regions, magnifying the electrophoretic component of transport, which contributes to a lesser, cargo- and parameter-dependent degree in bulk and micro-electroporation as well, to achieve rapid, high-efficiency cargo delivery. Advances in device architecture, including microchannels, high aspect ratio nanostructures, nanochannel arrays, and nanofountain probes, have expanded capabilities across gene delivery, tissue engineering, drug screening, cell lysis, and cell fusion. Beyond cargo transport, the applied field is increasingly used as a biological stimulus, modulating extracellular vesicle secretion and cargo content for cell engineering and biomanufacturing. Nevertheless, challenges persist: achieving uniform pore geometry, preserving viability, scaling throughput, and translating in vitro designs to in vivo contexts. Ongoing innovations in electrode materials, fabrication techniques, and integrated microfluidic systems promise to overcome these barriers, positioning MEP/NEP as a versatile platform for accelerating biomedical research and therapeutic development.