Huanghong Sun

Huanghong Sun

Auto-generated profile, based on publicly available information

Huanghong Sun

School of Communications and Information Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
YLYin Liu
Yin Liu
HSHuanghong Sun
Huanghong Sun
QLQiang Li
Qiang Li
KLKangkang Li
Kangkang Li
XFXinxing Fu
Xinxing Fu
CGCHENQIANG GAO
CHENQIANG GAO
Accurate recognition of auditory brainstem response (ABR) wave latencies is essential for clinical practice but remains a subjective and time-consuming process. Existing AI approaches face challenges in generalization, complexity, and semantic sparsity due to single sampling-point analysis. This study introduces the Derivative-Guided Patch Dual-Attention Transformer (Patch-DAT), a novel, lightweight, and generalizable deep learning (DL) model for the automated recognition of latencies for waves I, III, and V. Patch-DAT divides the ABR time series into overlapping patches to aggregate semantic information, better capturing local temporal patterns. Meanwhile, leveraging the fact that ABR waves occur at the zero crossing of the first derivative, Patch-DAT incorporates a first derivative-guided dual-attention mechanism to model global dependencies. Trained and validated on large-scale, diverse datasets from two hospitals, Patch-DAT(with a size of 0.36 MB) achieves accuracies of 92.29% and 98.07% at 0.1 ms and 0.2 ms error scales, respectively, on a held-out test set. It also performs well on an independent dataset with accuracies of 88.50% and 95.14%, demonstrating strong generalization across clinical settings. Ablation studies highlight the contributions of the patching strategy and dual-attention mechanisms. Compared to previous state-of-the-art DL models, Patch-DAT shows superior accuracy and reduced complexity, making it a promising solution for object recognition of ABR latencies. Additionally, we systematically investigate how sample size and data heterogeneity affect model generalization, indicating the importance of large, diverse datasets in training robust DL models. Future work will focus on expanding dataset diversity and improving model interpretability to further improve clinical relevance.

30 April 2026 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
YLYin Liu
Yin Liu
HSHuanghong Sun
Huanghong Sun
WZWeiwen Zhang
Weiwen Zhang
QLQiang Li
Qiang Li
XFXinxing Fu
Xinxing Fu
CGCHENQIANG GAO
CHENQIANG GAO
Auditory brainstem response (ABR) is widely used in clinical practice to assess hearing, with thresholds typically determined by clinicians via visual inspection—a process prone to human bias. Various statistical methods have therefore been developed to assist clinicians with this task and improve test accuracy and efficiency. However, existing methods primarily focus on determining the presence or absence of an ABR at a single stimulus level, thereby neglecting inter-level correlations that hold valuable information. This work proposes the Dynamic Time Warping (DTW)-Aware Series-Temporal Transformer (DTWA-STformer), a novel deep learning framework for automated ABR threshold estimation from a series of ABR waveforms. DTWA-STformer employs a DTW similarity-aware Series Transformer to capture inter-waveform dependencies, enhanced by stimulus level-informed positional encodings. A hierarchical multi-scale Temporal Transformer then extracts rich temporal representations, followed by a multi-class classifier for threshold prediction. The model was trained and evaluated on three pre-recorded datasets, including two large-scale human datasets (Dataset I: 8,350 subjects; Dataset II: 136 subjects) and a public mouse dataset (8,259 mice). The model achieved exact-match/±10 dB accuracies of 92.08%/99.31% (Dataset I), 90.35%/98.75% (Dataset II), 73.45%/99.27% (mouse click ABRs), and 60.85%/98.82% (mouse tone-pip ABRs), outperforming existing state-of-the-art methods for threshold estimation across both human and mouse data. Results show that DTWA-STformer provides accurate and objective threshold estimation from pre-recorded waveforms and may serve as a post hoc tool for verifying examiner-estimated thresholds. In future work, the approach could be integrated with active learning rules for dynamically selecting stimulus levels and more efficiently homing in on hearing threshold.