Aim: To report two phase I studies of the novel subcutaneous glucagon‐like peptide‐1 receptor/glucagon receptor (GLP‐1R/GCGR) dual agonist BI 456906 versus placebo in healthy volunteers and people with overweight/obesity. Materials and Methods: A phase Ia study (NCT03175211) investigated single rising doses (SRDs) of BI 456906 in 24 males with a body mass index (BMI) of 20–<30 kg/m 2 . A phase Ib study (NCT03591718) investigated multiple rising doses (MRDs) of BI 456906 (escalated over 6 [Part A] or 16 [Part B] weeks) in 125 adults with a BMI of 27–40 kg/m 2 . Results: In the SRD study (N = 24), mean body weight decreased with increasing BI 456906 dose. In the MRD study, the maximum decreases in placebo‐corrected mean body weight were at week 6 (–5.79%, dosage schedule [DS] 1; Part A) and week 16 (–13.8%, DS7; Part B). BI 456906 reduced plasma amino acids and glucagon, indicating target engagement at GCGRs and GLP‐1Rs. Drug‐related adverse events (AEs) increased with BI 456906 dose. The most frequent drug‐related AE with SRDs was decreased appetite (n = 9, 50.0%), and two subjects (8.3%) did not complete the trial because of AEs (nausea and vomiting). During MRD Part A (N = 80), 10 subjects (12.5%) discontinued BI 456906, most commonly because of a cardiac or vascular AE (n = 6, 7.5%); during Part B (N = 45), eight subjects (17.8%) discontinued BI 456906, mainly because of AEs (n = 6, 13.3%), most commonly gastrointestinal disorders. Conclusions: BI 456906 produced a placebo‐corrected body weight loss of 13.8% (week 16), highlighting its potential to promote clinically meaningful body weight loss in people with overweight/obesity.
Purpose: Ultra rapid lispro (URLi) is a novel insulin lispro formulation developed to more closely match physiological insulin secretion and improve postprandial glucose control. This study compared the pharmacokinetic and glucodynamic parameters of URLi and Lispro (Humalog (R)) at 3 dose levels in healthy subjects. Methods: This randomized, 6-period, subject- and investigator-blind, crossover study included 42 healthy subjects. At each period, subjects received a single subcutaneous dose of 7, 15, or 30 U of URLi or Lispro followed by a 10-h automated euglycemic clamp. Insulin lispro and blood glucose concentrations were measured. Findings: Across all 3 doses, insulin lispro appeared in the serum 2-5 min faster, and exposure was 6- to 8-fold greater in the first 15 min, with URLi versus Lispro. Exposure beyond 3 h postdose was 45%-52% lower, and duration of exposure was 67-86 min shorter with URLi versus Lispro for all dose levels. Onset of insulin action was 7-9 min faster and insulin action was similar to 3-fold greater in the first 30 min with URLi versus Lispro across the dose levels. Insulin action beyond 4 h was reduced by 32%-45%, and duration of action was reduced by 47-67 min, with URLi versus Lispro for all 3 dose levels. Overall exposure and total glucose infused were similar between URLi and Lispro at each dose level. Dose proportionality was observed for maximum and overall exposure after URLi. Less than dose-proportional increases in maximum and total glucose infused were observed and were similar for both URLi and Lispro. Implications: URLi exhibited ultra-rapid pharmacokinetic and glucodynamic parameters across all 3 dose levels studied and exhibited doseproportional increases in exposure in healthy subjects. (c) 2020 The Authors. Published by Elsevier Inc.
22 December 2022 in Diabetes, Obesity and Metabolism
Aims: To study the oral 11 beta‐hydroxysteroid dehydrogenase‐1 (11β‐HSD1) inhibitor BI 187004 (NCT02150824), as monotherapy and in combination with metformin, versus placebo in patients with type 2 diabetes mellitus (T2DM) affected by overweight or obesity. Materials and Methods: This Phase II, randomized controlled trial investigated multiple rising doses of BI 187004 as monotherapy (Arm 1: 20, 80 or 240 mg) and in combination with metformin (Arm 2: 240 mg), in adults with T2DM and a body mass index of 28–40 kg/m 2 . Results: In total, 103 patients (Arm 1: n = 62, Arm 2: n = 41) were included in this study. BI 187004 was rapidly absorbed and exposure increased approximately dose‐dependently. Target engagement of 11β‐HSD1 was observed with near‐full inhibition of 11β‐HSD1 in the liver [decreased (5α‐tetrahydrocortisol + 5β‐tetrahydrocortisol)/tetrahydrocortisone ratio]; hypothalamic–pituitary–adrenal axis activation was also seen (increased total urinary corticosteroids). No clinically relevant changes from baseline with BI 187004 treatment were observed for bodyweight or meal tolerance test parameters, or in most efficacy endpoints testing glucose and lipid metabolism; a significant increase was observed in weighted mean plasma glucose ( p < .05 for 80 and 240 mg BI 187004) but not fasting plasma glucose. Drug‐related adverse events were reported for 14 patients (22.6%) in Arm 1 and 10 patients (24.4%) in Arm 2, most frequently headache, diarrhoea, flushing and dizziness. A dose‐dependent increase in heart rate was seen with BI 187004 treatment. Conclusions: BI 187004 was generally well tolerated in patients with T2DM. Despite complete 11β‐HSD1 inhibition, no clinically relevant effects were observed with BI 187004.
27 April 2023 in Journal of Diabetes Science and Technology
Background: A noninvasive, wearable continuous glucose monitor would be a major advancement in diabetes therapy. This trial investigated a novel noninvasive glucose monitor which analyzes spectral variations in radio frequency/microwave signals reflected from the wrist. Methods: A single-arm, open-label, experimental study compared glucose values from a prototype investigational device with laboratory glucose measurements from venous blood samples (Super GL Glucose Analyzer, Dr. Müller Gerätebau GmbH) at varying levels of glycemia. The study included 29 male participants with type 1 diabetes (age range = 19-56 years). The study comprised three stages with the following aims: (1) demonstrate initial proof-of-principle, (2) test an improved device design, and (3) test performance on two consecutive days without device recalibration. The co-primary endpoints in all trial stages were median and mean absolute relative difference (ARD) calculated across all data points. Results: In stage 1, the median and mean ARDs were 30% and 46%, respectively. Stage 2 produced marked performance improvements with a median and mean ARD of 22% and 28%, respectively. Stage 3 showed that, without recalibration, the device performed as well as the initial prototype (stage 1) with a median and mean ARD of 35% and 44%, respectively. Conclusion: This proof-of-concept study shows that a novel noninvasive continuous glucose monitor was capable of detecting glucose levels. Furthermore, the ARD results are comparable to first models of commercially available minimally invasive products without the need to insert a needle. The prototype has been further developed and is being tested in subsequent studies. Trial registration number: NCT05023798.