Adrien Jossart

Adrien Jossart

Auto-generated profile, based on publicly available information

Adrien Jossart

Cardiovascular Jolimont Hospital La Louvière Belgium

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2025 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
ASAgostino Spano'
Agostino Spano'
OBOle De Backer
Ole De Backer
Ignacio J. Amat-SantosIgnacio J. Amat-Santos
Ignacio J. Amat-Santos
MBMarouane Boukhris
Marouane Boukhris
AJAdrien Jossart
Adrien Jossart
CUClaudiu Ungureanu
Claudiu Ungureanu

25 March 2026 in JACC: Case Reports
Verified
Journal Article
Open access
CUClaudiu Ungureanu
Claudiu Ungureanu
Grigorios TsigkasGrigorios Tsigkas
Grigorios Tsigkas
QTQuentin Trefois
Quentin Trefois
AJAdrien Jossart
Adrien Jossart
ZRZoltán Ruzsa
Zoltán Ruzsa
GCGiuseppe Colletti
Giuseppe Colletti
Radial artery access is the preferred route for percutaneous coronary intervention; however, severe calcification may prevent sheath and catheter advancement, particularly in patients with diffuse peripheral artery disease. A 74-year-old man with multiple cardiovascular risk factors was referred for left anterior descending artery percutaneous coronary intervention. The right radial artery was the only conventional access due to bilateral femoral artery disease and prior left radial occlusion. After successful puncture, catheter advancement was impeded by dense proximal radial calcification. After failure of conventional techniques, rotational atherectomy was performed within the radial artery, enabling successful lesion crossing and procedural completion. The decision to perform radial rotational atherectomy, rather than crossover to another vascular access, was driven by the absence of safer alternatives. Although established for coronary calcified lesions, this technique has not been described for radial access preparation. Intravascular ultrasound confirmed multiple calcium fractures and adequate luminal expansion without clinically significant vascular injury. Radial rotational atherectomy may represent a controlled bailout strategy to preserve the safest vascular access when standard approaches fail.

7 April 2026 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
CUClaudiu Ungureanu
Claudiu Ungureanu
GLGregor Leibundgut
Gregor Leibundgut
GCGiuseppe Colletti
Giuseppe Colletti
SDSilviu Dumitrascu
Silviu Dumitrascu
ASAgostino Spano'
Agostino Spano'
MBMarouane Boukhris
Marouane Boukhris

1 January 2026 in Case Reports in Cardiology
Verified
Journal Article
Open access
PDF file
JMJustine Massart
Justine Massart
CUClaudiu Ungureanu
Claudiu Ungureanu
YDYves Dascotte
Yves Dascotte
JAJacques Auslender
Jacques Auslender
AJAdrien Jossart
Adrien Jossart
Background: Type II heparin‐induced thrombocytopenia (HIT) is a catastrophic immunothrombotic disorder that can be triggered by minimal heparin exposure during routine coronary angiography. Case Summary: A 67‐year‐old woman developed “explosive” multiterritorial arterial thrombosis—including acute limb ischemia, an inferior STEMI, and a stroke—within minutes of receiving 5000 units of intra‐arterial heparin. This followed a brief nadroparin exposure 8 days prior. Crucially, events occurred while platelet counts were still normal. Despite a negative functional assay, a high 4T score (6 points) confirmed HIT. Management involved non‐heparin anticoagulation (danaparoid sodium) and thrombectomies. Discussion: This case highlights a major diagnostic pitfall: severe arterial thrombosis preceding overt thrombocytopenia. The immediate “anaphylactoid‐like” reaction following a heparin bolus is often misidentified as contrast allergy, delaying life‐saving intervention. Take Home Messages: Suspect HIT in acute systemic reactions or multifocal thrombosis after heparin exposure, regardless of initial platelet counts.

13 March 2026 in JACC: Case Reports
Verified
Journal Article
Open access
AJAdrien Jossart
Adrien Jossart
GLGregor Leibundgut
Gregor Leibundgut
GCGiuseppe Colletti
Giuseppe Colletti
MCMihai Cocoi
Mihai Cocoi
MBMarouane Boukhris
Marouane Boukhris
CUClaudiu Ungureanu
Claudiu Ungureanu
Guidewire entrapment in previously stented peripheral vessels is a rare but potentially hazardous complication during percutaneous coronary intervention, particularly in device-related mechanisms involving interaction with implanted metallic structures. A 70-year-old woman undergoing left main percutaneous coronary intervention developed irreversible entrapment of a 0.014-inch coronary guidewire within a brachiocephalic trunk stent. Conventional radial retrieval failed. A bailout strategy-GRASP (guided retrieval with assisted stent protection)-combining secondary femoral access, balloon-assisted stent anchoring, and simultaneous radial snaring, enabled controlled extraction while preserving stent integrity. Device-related entrapment carries increased risk of prosthesis deformation, vascular injury, or material rupture. Balloon-assisted stabilization with bidirectional control may facilitate safe retrieval in complex scenarios. Distinguishing anatomical from device-related entrapment guides management. The GRASP technique may offer a safe bailout option for complex device-related retrieval.

28 July 2026 in Journal of the Society for Cardiovascular Angiography & Interventions
Verified
Journal Article
Open access
TYTroels Yndigegn
Troels Yndigegn
PBPer Bondesson
Per Bondesson
GOGöran K. Olivecrona
Göran K. Olivecrona
HWHenrik Wagner
Henrik Wagner
SKSasha Koul
Sasha Koul
MMMoman A. Mohammad
Moman A. Mohammad