Purpose: This study aimed to review and pool the current literature on intra-articular ozone injection in knee osteoarthritis (OA) patients. Methods: A systematic review of three big databases was performed to identify all English-language randomized clinical trials (RCTs) that evaluated the efficacy of intra-articular ozone injection vs a control injection for knee OA sufferers, using the following two measuring tools: pain VAS and Western Ontario and McMaster Universities Arthritis Index (WOMAC). Results: A total of 428 patients in five RCTs were included, from which 53% (n=225) were in the ozone group and 47% in the control (hyaluronic acid [HA], dextrose, and air injection) group (n=203). The mean age of the patients in both groups was 64 years. Females were the majority. All studies had at least 2 months of follow-up (F/U). Mean difference (MD) between the groups for VAS in the first month was –0.23 with a P-value of 0.71 (negative value was in favor of ozone), whereas this difference in the third and sixth months reached 1.04 and 1.31, respectively, favoring the control group. These data demonstrated that control injection had a more prolonged pain relief period. A similar trend was seen regarding WOMAC scores; pooled results showed that ozone was slightly better than the control injections during the first month (MD =–7.84 [P=0.15]), but it declined to MD=2.55 and 8.23 at 2- to 3- and 4- to 6-month F/U, respectively, again in favor of control injections. Also, adverse events occurred homogeneously in both ozone (6/150 cases, 4%) and control groups (7/129 cases, 5.4%; P-value=0.31). Conclusion: Based on the current meta-analysis, intra-articular ozone injection efficacy was significantly superior to placebo and slightly lower to other control injections with non-significant difference. Therefore, ozone could be recommended as an efficient non-surgical treatment, durable for at least 3–6 months, in mild or moderate knee OA management.
Post-hysterectomy histopathological examination is currently the main diagnostic tool for differentiating uterine sarcomas from leiomyomas. This study aimed to investigate the diagnostic accuracy of preoperative quantitative metrics based on T2-weighted sequences and contrast-enhanced MRI (CE-MRI) for distinguishing uterine sarcomas from leiomyomas. The institutional review board approved the study. Sixty-five women confirmed to have a total of 105 lesions participated. Routine pelvic MRI sequences, T2 map and CE-MRI images were performed preoperatively using a 3 T MR scanner. Six quantitative metrics—T2 mapping parameter, T2 scaled ratio, tumor myometrium contrast ratio on T2, tumor psoas contrast ratio on T2, tumor myometrium contrast-enhanced ratio, and tumor psoas contrast-enhanced ratio—were extracted from the acquired image sets. Chi-square test was used to compare the percentage of malignant lesions with the central necrosis to the corresponding percentage for the benign masses. Using the area under receiver operating characteristic (AUC) curve, the performance of different metrics for distinguishing uterine sarcomas from leiomyomas was measured. Moreover, for each metric, we extracted the optimal cut-off value. The values of sensitivity, specificity, negative predictive value, and positive predictive value were calculted for the classifiers based on different metrics. The average age, average lesion size, and proportion of premenopausal women in benign and malignant groups were comparable in our dataset. The signal intensity of uterine sarcomas at T2-weighted sequences was significantly higher than that of leiomyomas (p < 0.001), while intensity at T1-weighted sequences exhibited no significant difference between the two masses (p = 0.201). Our data also suggested that a central necrosis was ten times more common among malignant lesions compared to benign ones (p < 0.001). Among different metrics, T2 mapping parameter achieved the highest AUC value and accuracy in differentiating two groups. Three measures—T2 scaled ratio, tumor myometrium contrast ratio on T2, and tumor myometrium contrast-enhanced ratio—achieved a sensitivity of 100%, therefore none of the malignant lesions would have been missed if these metrics had been adopted in patient management. The findings suggested that the evaluated metrics could be useful in the preoperative assessment of myometrial masses to differentiate uterine sarcomas from leiomyomas. The proposed framework has major implications for improving current practice in the management of myometrial masses.
BACKGROUND:There are few reports of breast cancer cases with uterine metastases; among them, myometrium is more frequently involved than endometrium. The majority of breast cancer metastases to endometrium are lobular type, and there have been only 5...
This study aimed to develop a diagnostic algorithm for preoperative differentiating uterine sarcoma from leiomyoma through a supervised machine-learning method using multi-parametric MRI. A total of 65 participants with 105 myometrial tumors were included: 84 benign and 21 malignant lesions (belonged to 51 and 14 patients, respectively; based on their postoperative tissue diagnosis). Multi-parametric MRI including T1-, T2-, and diffusion-weighted (DW) sequences with ADC-map, contrast-enhanced images, as well as MR spectroscopy (MRS), was performed for each lesion. Thirteen singular MRI features were extracted from the mentioned sequences. Various combination sets of selective features were fed into a machine classifier (coarse decision-tree) to predict malignant or benign tumors. The accuracy metrics of either singular or combinational models were assessed. Eventually, two diagnostic algorithms, a simple decision-tree and a complex one were proposed using the most accurate models. Our final simple decision-tree obtained accuracy = 96.2%, sensitivity = 100% and specificity = 95%; while the complex tree yielded accuracy, sensitivity and specificity of 100%. To summarise, the complex diagnostic algorithm, compared to the simple one, can differentiate tumors with equal sensitivity, but a higher specificity and accuracy. However, it needs some further time-consuming modalities and difficult imaging calculations. Trading-off costs and benefits in appropriate situations must be determinative.