10 October 2023 in Microsystems & Nanoengineering
Bacterial cellulose (BC), a natural biomaterial synthesized by bacteria, has a unique structure of a cellulose nanofiber-weaved three-dimensional reticulated network. BC films can be ultrasoft with sufficient mechanical strength, strong water absorption and moisture retention and have been widely used in facial masks. These films have the potential to be applied to implantable neural interfaces due to their conformality and moisture, which are two critical issues for traditional polymer or silicone electrodes. In this work, we propose a micro-electrocorticography (micro-ECoG) electrode named “Brainmask”, which comprises a BC film as the substrate and separated multichannel parylene-C microelectrodes bonded on the top surface. Brainmask can not only guarantee the precise position of microelectrode sites attached to any nonplanar epidural surface but also improve the long-lasting signal quality during acute implantation with an exposed cranial window for at least one hour, as well as the in vivo recording validated for one week. This novel ultrasoft and moist device stands as a next-generation neural interface regardless of complex surface or time of duration.
28 February 2024 in Biosensors and Bioelectronics
28 August 2024 in ACS Nano
22 September 2022 in IEEE Electron Device Letters
Pulsed field ablation is an emerging technique for the treatment of atrial fibrillation, and it can specifically damage cardiomyocytes without destroying surrounding tissues. However, current single-function ablation electrodes apply electric pulses at thousands of volts, which is potentially harmful to the heart. In this letter, we propose a multifunctional microelectrode for low-voltage pulsed field ablation and effect evaluation. By using finite element analysis and tests on potato tissues and in vivo experiments, we show that the soft microelectrode in multiplexed array format supports two orders of magnitude reduction in ablation voltage compared with the state of the art. Meanwhile, the electrode-tissue equivalent circuit before and after irreversible electroporation is established, and we find that the ablation effect could be evaluated by impedance. In the future, the microelectrode integrated with a medical balloon can be applied to minimally invasive surgery for improving the success rate of pulsed field ablation.
23 January 2025 in Microsystems & Nanoengineering
Precise and long-term electroanalysis at the single-cell level is crucial for the accurate diagnosis and monitoring of brain diseases. The reliable protection in areas outside the signal acquisition points at sharp ultramicroelectrode (UME) tips has a significant impact on the sensitivity, fidelity, and stability of intracellular neural signal recording. However, it is difficult for existing UMEs to achieve controllable exposure of the tip functional structure, which affects their ability to resist environmental interference and shield noise, resulting in unsatisfactory signal-to-noise ratio and signal fidelity of intracellular recordings. To address this issue, we chose a dense and electrochemically stable diamond-like carbon (DLC) film as the UME protection coating and developed a method to precisely control the exposed degree of the functional structure by directly fixed-point processing of the UME tip by the strong site-selectivity and good controllability of the atmospheric microplasma jet. By analyzing the interaction between the microplasma jet and the UME tip, as well as the changes in the removal length and microstructure of UME tips with processing time, the exposed tip length was precisely controlled down to the submicron scale. Biocompatibility experiments, electrochemical aging tests and real-time intracellular pH recording experiments have demonstrated that the DLC-UME with effective tip protection processed by microplasma jet has the potential to enable long-term detection of intracellular high-fidelity signals.
16 December 2024 in IEEE Transactions on Biomedical Engineering
Objective: Microneedle electrodes are a promising solution to the long-term collection of high-quality electroencephalography (EEG) signals without skin preparation. However, conventional microneedle electrodes still suffer from poor spatial resolution due to the volume conduction effect, which results in signal aliasing from adjacent electrodes and interference from remote sources. Methods: Here, we introduce the design, fabrication, and application of an iridium oxide (IrOx) concentric ring microneedle electrode (CRME) for surface Laplacian EEG (SLEEG) signals recording. The fabrication of a concentric ring structure with microneedles distributed on every ring is realized through high-precision 3D printing, replica molding, laser cutting, and sputtering technology, which can improve spatial resolution. Results: The contact impedance density of the IrOx CRME reduces by about 13 times compared to a common-used AgCl dry electrode and is lower than that of a standard wet electrode. Meanwhile, the IrOx CRME can acquire signals with a higher signal-noise ratio (SNR) and lower background noise. Besides, the mutual information between signals from adjacent IrOx CRMEs is lower than that from traditional microneedle electrodes (reduced from 0.8-0.9 to 0.1-0.2). The signal tests on the forehead reveal that the proposed electrodes can overcome the interference and are sensitive to close frontal lobe theta wave sources. Conclusion: The IrOx CRME shows low contact impedance, high SNR, and selectivity to close sources. Significance: This work improves traditional microneedle electrodes with combining concentric ring structure and can potentially promote the detection of the theta wave benefiting applications such as the monitoring of fatigue and stress.