Ralph Laube

Ralph Laube

Auto-generated profile, based on publicly available information

Ralph Laube

Max-Planck-Institut für Plasmaphysik 2 , 17491 Greifswald

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2020 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Open access
PDF file
CBC Brandt
C Brandt
JSJ Schilling
J Schilling
HTH Thomsen
H Thomsen
TBT Broszat
T Broszat
RLR Laube
R Laube
TST Sieber
T Sieber
The soft x-ray tomography diagnostic in the stellarator Wendelstein 7-X consists of twenty pinhole cameras, up–down symmetrically arranged in a poloidal, triangular cross-section of the plasma vessel. The x-ray emissivity is measured with 16 bit amplitude resolution at 2 MHz sampling rate along 360 lines-of-sight by silicon photodiode arrays. In the recent operation campaign data acquisition (DAQ) has been working reliable for the conducted plasma pulse lengths <1 min, however the DAQ system are ready for the foreseen 30 min plasma pulse lengths of upcoming campaigns. The bandwidth of the preamplifiers is ≈200 kHz and the sensitive energy range is approximately 1–12 keV. The measurements indicate the up–down symmetric emissivity distribution in the triangular poloidal cross-section. First tomographic reconstructions of different magnetic field configurations are consistent with the theoretically calculated flux surface topology.

1 September 2024 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
JTJ. L. Terry
J. L. Terry
ASA. von Stechow
A. von Stechow
SBS. G. Baek
S. G. Baek
SBS. B. Ballinger
S. B. Ballinger
OGO. Grulke
O. Grulke
WTW7-X Team
W7-X Team
A system for studying the spatiotemporal dynamics of fluctuations in the boundary of the W7-X plasma using the “Gas-Puff Imaging” (GPI) technique has been designed, constructed, installed, and operated. This GPI system addresses a number of challenges specific to long-pulse superconducting devices, such as W7-X, including the long distance between the plasma and the vacuum vessel wall, the long distance between the plasma and diagnostic ports, the range of last closed flux surface (LCFS) locations for different magnetic configurations in W7-X, and management of heat loads on the system’s plasma-facing components. The system features a pair of “converging–diverging” nozzles for partially collimating the gas puffed locally ≈135 mm radially outboard of the plasma boundary, a pop-up turning mirror for viewing the gas puff emission from the side (which also acts as a shutter for the re-entrant vacuum window), and a high-throughput optical system that collects visible emission resulting from the interaction between the puffed gas and the plasma and directs it along a water-cooled re-entrant tube directly onto the 8 × 16 pixel detector array of the fast camera. The DEGAS 2 neutral code was used to simulate the Hα (656 nm) and HeI (587 nm) line emission expected from well-characterized gas-puffs of H2 and He and excited within typical edge plasma profiles in W7-X, thereby predicting line brightnesses used to reduce the risks associated with system sensitivity and placement of the field of view. Operation of GPI on W7-X shows excellent signal-to-noise ratios (>100 at 2 Mframes/s) over the field of view for minimally perturbing gas puffs. The GPI system provides detailed measurements of the two-dimensional (radial and poloidal) dynamics of plasma fluctuations in the W7-X edge and scrape-off layer and in and around the magnetic islands outside the LCFS that make up the island divertor configuration employed on W7-X.

1 January 2020 in Fusion Engineering and Design
Verified
Journal Article
Closed access
RLRalph Laube
Ralph Laube
RBRene Bussiahn
Rene Bussiahn
NTNaoki Tamura
Naoki Tamura
KMKieran J. McCarthy
Kieran J. McCarthy

1 August 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
DDD. R. Demers
D. R. Demers
TCT. P. Crowley
T. P. Crowley
PFP. J. Fimognari
P. J. Fimognari
HMH. Trimino Mora
H. Trimino Mora
OGO. Grulke
O. Grulke
RLR. Laube
R. Laube
A heavy ion beam probe (HIBP) diagnostic is being developed for studies of plasma equilibrium and turbulence in the optimized Wendelstein 7-X (W7-X) stellarator. Operation of W7-X has experimentally demonstrated that its optimized magnetic field results in improved neoclassical particle confinement and, as a result, turbulence is the predominant cause of energy transport. The HIBP will have the unique ability to provide experimental data needed to complement models of both neoclassical and turbulent transport. It will acquire direct measurements in the W7-X plasma interior of the electric potential (needed for understanding ambipolar particle flux) and fluctuations of electron density and potential (needed for understanding turbulence). The HIBP for W7-X will inject singly charged ion beams with energies of up to 2 MeV and is designed to access the upper cross section of the W7-X plasma. We use trajectory simulations to illustrate the plasma coverage that the diagnostic can achieve in the reference magnetic configurations of W7-X. We calculate beam signal levels, discuss anticipated measurement sensitivity of broadband fluctuations of electron density and plasma potential, and show how they depend on plasma density. We also discuss the diagnostic sensitivity to equilibrium plasma potential.

1 March 2026 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
XHX. Han
X. Han
DSD. R. Smith
D. R. Smith
TWT. Windisch
T. Windisch
RLR. Laube
R. Laube
OFO. Ford
O. Ford
WTWendelstein 7-X Team
Wendelstein 7-X Team
A low-noise, high-speed optical detector module is characterized and successfully commissioned for the measurement of high-frequency, low-intensity beam emission on Wendelstein 7-X (W7-X). An ultra-narrow bandpass optical filter is employed to selectively transmit the desired emission line while suppressing broadband plasma background emissions. Carbon density fluctuations are investigated by observing the carbon C-VI emission line (n = 8 → 7, λ ∼ 529 nm), arising from charge exchange (CX) between the neutral beam atoms and the intrinsic carbon population. We present the characterization of the optical detector module and experimental measurements of carbon density fluctuations using available fibers on W7-X. The initial performance of the detector is presented in both active and passive CX measurements of intrinsic carbon density fluctuations. The low frequency dynamics of fluctuation is observed in response to the neutral beam and the pellet injection, demonstrating that the optical detector module is capable of providing a sufficient signal level with an adequate signal-to-noise ratio. In the upcoming OP2.4 campaign, this optical detector module will be adapted for use in a beam emission spectroscopy system by replacing the optical bandpass filter with one centered at 654 nm (90% transmission: 653–655.3 nm), which facilitates two-dimensional measurements of ion gyro-scale turbulence on W7-X.