1 February 2021 in Monthly Notices of the Royal Astronomical Society
We have entered a new era where integral-field spectroscopic surveys of galaxies are sufficiently large to adequately sample large-scale structure over a cosmologically significant volume. This was the primary design goal of the SAMI Galaxy Survey. Here, in Data Release 3, we release data for the full sample of 3068 unique galaxies observed. This includes the SAMI cluster sample of 888 unique galaxies for the first time. For each galaxy, there are two primary spectral cubes covering the blue (370–570 nm) and red (630–740 nm) optical wavelength ranges at spectral resolving power of R = 1808 and 4304, respectively. For each primary cube, we also provide three spatially binned spectral cubes and a set of standardized aperture spectra. For each galaxy, we include complete 2D maps from parametrized fitting to the emission-line and absorption-line spectral data. These maps provide information on the gas ionization and kinematics, stellar kinematics and populations, and more. All data are available online through Australian Astronomical Optics Data Central.
30 August 2017 in The Astrophysical Journal
The spatial distribution of oxygen in the interstellar medium of galaxies is the key to understanding how efficiently metals that are synthesized in massive stars can be redistributed across a galaxy. We present here a case study in the nearby spiral galaxy NGC 1365 using 3D optical data obtained in the TYPHOON Program. We find systematic azimuthal variations of the H ii region oxygen abundance imprinted on a negative radial gradient. The 0.2 dex azimuthal variations occur over a wide radial range of 0.3–0.7 R 25 and peak at the two spiral arms in NGC 1365. We show that the azimuthal variations can be explained by two physical processes: gas undergoes localized, sub-kiloparsec-scale self-enrichment when orbiting in the inter-arm region, and experiences efficient, kiloparsec-scale mixing-induced dilution when spiral density waves pass through. We construct a simple chemical evolution model to quantitatively test this picture and find that our toy model can reproduce the observations. This result suggests that the observed abundance variations in NGC 1365 are a snapshot of the dynamical local enrichment of oxygen modulated by spiral-driven, periodic mixing and dilution.
31 August 2018 in Monthly Notices of the Royal Astronomical Society
We present the second major release of data from the Sydney – Australian Astronomical Observatory Multi-Object Integral Field Spectrograph (SAMI) Galaxy Survey. Data Release Two includes data for 1559 galaxies, about 50 per cent of the full survey. Galaxies included have a redshift range 0.004 < $$z$$ < 0.113 and a large stellar mass range 7.5 < log (M⋆/M⊙) < 11.6. The core data for each galaxy consist of two primary spectral cubes covering the blue and red optical wavelength ranges. For each primary cube, we also provide three spatially binned spectral cubes and a set of standardized aperture spectra. For each core data product, we provide a set of value-added data products. This includes all emission line value-added products from Data Release One, expanded to the larger sample. In addition, we include stellar kinematic and stellar population value-added products derived from absorption line measurements. The data are provided online through Australian Astronomical Optics’ Data Central. We illustrate the potential of this release by presenting the distribution of $${\sim } 350\, 000$$ stellar velocity dispersion measurements from individual spaxels as a function of R/Re, divided in four galaxy mass bins. In the highest stellar mass bin [log (M⋆/M⊙) > 11], the velocity dispersion strongly increases towards the centre, whereas below log (M⋆/M⊙) < 10 we find no evidence for a clear increase in the central velocity dispersion. This suggests a transition mass around log (M⋆/M⊙) ∼ 10 for galaxies with or without a dispersion-dominated bulge.
5 July 2018 in Monthly Notices of the Royal Astronomical Society
We present gas-phase metallicity and ionization parameter maps of 25 star-forming face-on spiral galaxies from the SAMI Galaxy Survey Data Release 1. Self-consistent metallicity and ionization parameter maps are calculated simultaneously through an iterative process to account for the interdependence of the strong emission line diagnostics involving ([O ii]+[O iii])/Hβ (R23) and [O iii]/[O ii](O32). The maps are created on a spaxel-by-spaxel basis because H ii regions are not resolved at the SAMI spatial resolution. We combine the SAMI data with stellar mass, star formation rate (SFR), effective radius (Re), ellipticity, and position angles (PA) from the GAMA survey to analyse their relation to the metallicity and ionization parameter. We find a weak trend of steepening metallicity gradient with galaxy stellar mass, with values ranging from −0.03 to −0.20 dex/Re. Only two galaxies show radial gradients in the ionization parameter. We find that the ionization parameter has no significant correlation with either SFR, sSFR (specific SFR), or metallicity. For several individual galaxies, we find the structure in the ionization parameter maps suggestive of spiral arm features. We find a typical ionization parameter range of 7.0 < log (q) < 7.8 for our galaxy sample with no significant overall structure. An ionization parameter range of this magnitude is large enough to caution the use of metallicity diagnostics that have not considered the effects of a varying ionization parameter distribution.
4 May 2019 in Monthly Notices of the Royal Astronomical Society
We present a systematic study of the diffuse ionized gas (DIG) in M83 and its effects on the measurement of metallicity gradients at varying resolution scales. Using spectrophotometric data cubes of M83 obtained at the 2.5m duPont telescope at Las Campanas Observatory as part of the TYPHOON programme, we separate the H ii regions from the DIG using the [S ii]/H α ratio, HIIphot (H ii-finding algorithm), and the H α surface brightness. We find that the contribution to the overall H α luminosity is approximately equal for the H ii and DIG regions. The data is then rebinned to simulate low-resolution observations at varying resolution scales from 41 pc up to 1005 pc. Metallicity gradients are measured using five different metallicity diagnostics at each resolution. We find that all metallicity diagnostics used are affected by the inclusion of DIG to varying degrees. We discuss the reasons why the metallicity gradients are significantly affected by DIG using the H ii dominance and emission line ratio radial profiles. We find that applying the [S ii]/H α cut will provide a closer estimate of the true metallicity gradient up to a resolution of 1005 pc for all metallicity diagnostics used in this study.
29 January 2021 in Monthly Notices of the Royal Astronomical Society
We measure the gas-phase metallicity gradients of 248 galaxies selected from Data Release 2 of the SAMI Galaxy Survey. We demonstrate that there are large systematic discrepancies between the metallicity gradients derived using common strong emission line metallicity diagnostics. We determine which pairs of diagnostics have Spearman’s rank coefficients greater than 0.6 and provide linear conversions to allow the accurate comparison of metallicity gradients derived using different strong emission line diagnostics. For galaxies within the mass range 8.5 < log (M/M⊙) < 11.0, we find discrepancies of up to 0.11 dex/Re between seven popular diagnostics in the metallicity gradient–mass relation. We find a suggestion of a break in the metallicity gradient–mass relation, where the slope shifts from negative to positive, occurs between 9.5 < log (M/M⊙) < 10.5 for the seven chosen diagnostics. Applying our conversions to the metallicity gradient–mass relation, we reduce the maximum dispersion from 0.11 dex/Re to 0.02 dex/Re. These conversions provide the most accurate method of converting metallicity gradients when key emission lines are unavailable. We find that diagnostics that share common sets of emission line ratios agree best, and that diagnostics calibrated through the electron temperature provide more consistent results compared to those calibrated through photoionization models.