The effect of different acidic modifiers on the separation of seven selected phytoestrogens by reverse-phase high-performance liquid chromatography has been described. Variation in the hydrocarbon chain length of organic acids as represented by acetic acid, propanoic acid, iso-butyric acid, and n-butyric acid as additives to the mobile phase had minimal effect on the separation of phytoestrogens but notably reduced sample turnaround times relative to the turnaround time linked with formic acid. Two different C18 columns were evaluated in attempts of optimize the phytoestrogen separations. Formic acid as a modifier in the mobile phase and an Atlantis C18 column provided the best overall separation at optimum gradient conditions. A higher acid concentration in the mobile phase did not improve the phytoestrogen separation. Higher column temperature (40 °C) provided an improved separation. Finally, the optimized method was used to quantify different phytoestrogens in selected different botanical samples. For this purpose, both internal and external standard methods were compared to obtain the quantitative results. Graphical Abstract
The influence of additives and modifiers on the chiral HPLC separation of the nicotine enantiomers using UV/Vis detection is discussed. Selected alcohols as modifiers and selected amines as additives were found to have a significant effect on the resolution and retention times of nicotine enantiomers even to the point of eliminating component elution. Systematic variations in the concentration of ethanol, methanol, and isopropanol, as modifiers, along with variations in the concentration of diethylamine, triethylamine, tributylamine, ethylenediamine, isopropylamine, as additives, revealed that the average resolution (R) of the nicotine enantiomers ranged from 2.9 to 7.57, using a mobile phase flow rate of 0.80 mL/min. The average retention times of the nicotine enantiomer pairs ranged from 7.64 and 8.34 min to 13.47 and 14.97 min, with the S(−) enantiomer eluting first. As expected, faster flow rates of 1.0 mL/min reduced retention times by approximately 1–2 min, with a slight decrease in the R values. The %RSD values for both resolution and retention times consistently remained below 2%. The detection limits for the enantiomers were approximately 5 μg/mL. The optimized method successfully detected one part in 100 for the minor R(+) enantiomer in the presence of the dominate S(−) enantiomer and adhered to all established QuEChERS method protocols.
1 December 2018 in Beiträge zur Tabakforschung International/Contributions to Tobacco Research
Summary: Free amino acids have been isolated via optimized enzymatic hydrolysis of F1 tobacco protein using two cationic resins (Amberlite IR120 and Dowex MAC-2). Optimized enzymatic conversions of the protein as a result of systematic variations in conditions (e.g., time, temperature, pH, enzyme type, enzyme concentration, anaerobic/aerobic environments, and protein concentration) employing commercially available enzymes, were consistently higher than 50% with qualitative amino acid arrays that were consistent with the known composition of tobacco F1 protein. Amberlite IR120 was shown to have a much higher efficiency and capacity for isolation of amino acids from standard solutions and from hydrolysate when compared with the results using Dowex MAC-2. Two columns packed with conditioned Amberlite IR120 (120 × 10 mm,12–15 g resin) and (200 × 25.4 mm, 60–65 g resin) were used to isolate two batches (2.5–3.0 mg and 13–15 mg) of free amino acids, respectively. A relatively inexpensive analytical methodology was developed for rapid analysis of the free amino acids contained within the enzyme hydrolysate. Commercially available enzymes, when employed in optimized reaction conditions, are very effective for enzymatic conversion of tobacco F1 protein to free amino acids.
14 July 2023 in Journal of Chromatographic Science
An optimized method employing chiral supercritical fluid chromatography with diode array UV–VIS detection has been developed for the quantitative analysis of nicotine and nornicotine enantiomer distributions. The method parameters that were optimized included: column type (stationary phases, Chiralpak IG-3), column temperature (40°C), modifier types and concentration (isopropyl alcohol, 10%), additive types and concentrations (diethylamine, 0.2%), elution times (1.2). These optimized conditions led to nicotine and nornicotine enantiomer detection limits of ~5 ng/μL with accompanying %RSD values of <2% from the analyses of commercially available nicotine-containing formulations.