Kevin J. Zhu

Kevin J. Zhu

Auto-generated profile, based on publicly available information

Kevin J. Zhu

Department of Civil and Environmental Engineering, College of Engineering, Georgia Institute of Technology, Atlanta, Georgia, United States of America

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2023 in Water Research
Verified
Journal Article
Closed access
KZKevin Zhu
Kevin Zhu
CHCailee Hill
Cailee Hill
AMAaron Muirhead
Aaron Muirhead
MBMausumi Basu
Mausumi Basu
JBJoe Brown
Joe Brown
CSChristine Stauber
Christine Stauber

18 May 2022 in Environmental Science & Technology Letters
Verified
Journal Article
Open access
KZKevin J. Zhu
Kevin J. Zhu
BSBrittany Suttner
Brittany Suttner
JKJackie Knee
Jackie Knee
DCDrew Capone
Drew Capone
CMChristine Moe
Christine Moe
JBJoe Brown
Joe Brown
An end goal of fecal source tracking (FST) is to provide information on risk of transmission of waterborne illnesses associated with fecal contamination. Ideally, concentrations of FST markers in ambient waters would reflect exposure risk. Human mtDNA is an FST marker that is exclusively human in origin and may be elevated in feces of individuals experiencing gastrointestinal inflammation. In this study, we examined whether human mtDNA is elevated in fecal samples from individuals with symptomatic norovirus infections using samples from the United States (US), Mozambique, and Bangladesh. We quantified hCYTB484 (human mtDNA) and HF183/BacR287 (human-associated Bacteroides) FST markers using droplet digital polymerase chain reaction. We observed the greatest difference in concentrations of hCYTB484 when comparing samples from individuals with symptomatic norovirus infections versus individuals without norovirus infections or diarrhea symptoms: log10 increase of 1.42 in US samples (3,820% increase, p-value = 0.062), 0.49 in Mozambique (308% increase, p-value = 0.061), and 0.86 in Bangladesh (648% increase, p-value = 0.035). We did not observe any trends in concentrations of HF183/BacR287 in the same samples. These results suggest concentrations of fecal mtDNA may increase during symptomatic norovirus infection and that mtDNA in environmental samples may represent an unambiguously human source-tracking marker that correlates with enteric pathogen exposure risk.

9 February 2024 in Water Research
Verified
Journal Article
Closed access
GCGyuhyon Cha
Gyuhyon Cha
KZKevin J. Zhu
Kevin J. Zhu
JFJamie M. Fischer
Jamie M. Fischer
CFCamryn I. Flores
Camryn I. Flores
JBJoe Brown
Joe Brown
KGKatherine E. Graham
Katherine E. Graham

12 February 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
JBJoHannah Buehrer
JoHannah Buehrer
MLMegan Lott
Megan Lott
KZKevin J. Zhu
Kevin J. Zhu
KFKayla Fericy
Kayla Fericy
JGJoshua Granek
Joshua Granek
BTBarbara Turpin
Barbara Turpin
Healthcare Associated Infections (HAIs) pose a significant public health risk. Hospital sinks and associated plumbing are one likely source. This study investigates bioaerosol emissions from sink P-traps during faucet operation to assess their potential role in pathogen transmission in the hospital context. We designed an aerosol chamber system with adjustable air change rate and a functioning sink meeting hospital standards. We quantified bioaerosol and large droplet emission factors from the sink, using FAmpEscherichia coli as a model for Enterobacteriaceae such as Klebsiella pneumoniae. We cultured Andersen Cascade Impactor and BioSpot sampler aerosol samples and deposition plates using MI agar, which is selective for E. coli. Across five experiments, deposition plate counts were substantial, while air samples were close to detection limits. We estimated PM5.0 bioaerosol emissions factors of 1.3 x 10-10 to 1.9 x 10-10 CFU emitted per CFU in P-trap. Large droplet emission factor was one order of magnitude larger, at 4.3 x 10-9 ± 2.8 x 10-9 CFU per CFU. Results were used to predict Klebsiella pneumoniae inhalation dose (0.78 to 1.12 CFU day-1) and inhalation infection probability (∼10-5) for 5.5 day hospital stay with colonized plumbing (air change rate 6 h-1). This translates to ∼1 infection per year for a hospital with a severe plumbing system colonization affecting ∼2000 continuously occupied rooms. For pathogens with different dose response curves, we demonstrate how infection probability via inhalation depends on dose response.

13 October 2025 in PLOS Water
Verified
Journal Article
Open access
PDF file
FSFábio Neves Souza
Fábio Neves Souza
KZKevin J. Zhu
Kevin J. Zhu
DODaiana de Oliveira
Daiana de Oliveira
NJNivison Nery Jr
Nivison Nery Jr
JCJaqueline S. Cruz
Jaqueline S. Cruz
CSChristine E. Stauber
Christine E. Stauber
This study explores the use of human mitochondrial DNA (mtDNA) markers, specifically hCYTB484, as fecal source tracking (FST) tools for environmental surveillance in a high-density, low-income community in Salvador, Bahia, Brazil. Here, we hypothesized that hCYTB484 concentrations in wastewater would correlate with indicators of human pathogen exposure, such as viral antibody prevalence and helminth infections in rodents, both of which are potential zoonotic threats. Our study found that higher concentrations of mtDNA in wastewater were associated with increased viral exposure in humans and the presence of helminths in rodents. This suggests that fecal mtDNA could serve as a promising tool for environmental surveillance of pathogens in vulnerable communities. Our findings underscore the potential of mtDNA markers to be integrated into disease monitoring systems, particularly in resource-limited urban areas with inadequate sanitation. Implementing mtDNA-based tracking in environmental waters could strengthen early-warning systems for public health, allowing for a more proactive response to emerging health threats. Further research is needed to deepen our understanding of pathogen circulation and inform more effective public health interventions.