James Shih-Shyn Wu

James Shih-Shyn Wu

Auto-generated profile, based on publicly available information

James Shih-Shyn Wu

Department of Surgery, University of Toronto, Toronto, Ontario, Canada

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in JBJS Open Access
Verified
Journal Article
Open access
AKAmir Khoshbin
Amir Khoshbin
JWJames Wu
James Wu
SWSarah Ward
Sarah Ward
LMLuana T. Melo
Luana T. Melo
ESEmil H. Schemitsch
Emil H. Schemitsch
AAAmit Atrey
Amit Atrey
Background: The ideal bearing combination for total hip arthroplasty (THA) remains debatable. Highly cross-linked polyethylene (XLPE) is widely used, but long-term wear rates are not fully known, nor is how much the initial “creep,” if any, affects overall wear. Additionally, the use of oxidized zirconium (OxZir) is purported to lower polyethylene wear rates, but this has not been proven. We present the 10-year data of a cohort of patients who underwent THA. Patients were prospectively randomized to 1 of 4 bearing combinations: a conventional ultra-high molecular weight polyethylene (UHMWPE) or XLPE acetabular liner coupled with either a cobalt-chromium (CoCr) or OxZir femoral head. The aims of the study were to (1) assess the extent to which creep affected overall wear rates and (2) assess wear rates between OxZir and CoCr with polyethylene. Methods: A total of 92 hips (92 patients) between the ages of 22 and 65 years (mean, 52.2 ± 9.3 years) were randomized to 4 groups. At 10 years, 70 (76%) of the hips were available for analysis; patients who had undergone revision, had died, or were lost to follow-up were excluded from final analysis. Radiographic analysis was performed using a validated digital assessment program to determine linear, volumetric, and directional wear of the polyethylene for all 4 bearing couples. Radiographic assessments were performed immediately postoperatively, at 6 and 12 weeks, and then annually for a minimum of 10 years. Results: XLPE had significantly lower wear rates than UHMWPE. Once creep was eliminated, annual and overall wear rates were nearly 50% lower than have been previously reported. This was proportionally more important in the XLPE group than in the UHMWPE group. There was a nonsignificant trend toward a lower wear rate with OxZir heads. Conclusions: Creep plays a notably more important role than first thought. Once creep was eliminated, the overall wear rate was even lower than previously assumed. This has important implications for the overall survivorship of hip arthroplasty implants. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

1 January 2022 in JBJS Case Connector
Verified
Journal Article
Closed access
JWJames Wu
James Wu
COColby Oitment
Colby Oitment
JSJordan Silverman
Jordan Silverman
TGTyler M. Grey
Tyler M. Grey
KBKunal Bhanot
Kunal Bhanot
Case: The global reach of coronavirus disease 2019 has led to the rollout of new generation messenger ribonucleic acid (mRNA) vaccines. As populations are vaccinated, some side effects will become more apparent. We present a case of unilateral lymphadenopathy resulting in a transient plexopathy presenting as neuralgic pain, paresthesia, and numbness in the hand. Conclusion: Multiple image modalities and electrodiagnostic studies were used to infer the diagnosis. This condition was expectantly managed, and the patient’s symptoms resolved within weeks.

1 April 2016 in Advances in Mechanical Engineering
Verified
Journal Article
Open access
YLYi-Tsung Lin
Yi-Tsung Lin
JWJames Shih-Shyn Wu
James Shih-Shyn Wu
YLYuan-Lung Lai
Yuan-Lung Lai
Instead of obsessively emphasizing to reduce the number of time increments and reshape the models, a novel surface contact transformation to increase efficiency is presented in this study. Wear on the bearing surfaces was investigated following the coupled regions from the pressure distribution, computed by means of three-dimensional finite element method models; an approximate analytical model and formulation in three-dimensional frictional contact problems based on modified localized Lagrange multiplier method have also been developed and discussed. Understanding wear behavior patterns in mechanical components is a significant task in engineering design. The proposed approach provides a complete and effective solution to the wear problem in a quasi-dynamic manner. However, expensive computing time is needed in the incremental procedures. In this article, an alternative and efficient finite element approach is introduced to reduce the computation costs of wear prediction. Through the successful verification of wear depth and volume loss of the pin-on-plate, block-on-ring, and metal-on-plastic artificial hip joint wear behaviors, the numerical calculations are shown to be both valid and feasible. Furthermore, the results also show that the central processing unit time required by the proposed method is nearly half that of the previous methods without loss of accuracy.

1 January 2015
Verified
Conference Paper
Open access
PDF file
JWJames Shih-Shyn Wu
James Shih-Shyn Wu
YLYi-Tsung Lin
Yi-Tsung Lin
YLYuan-Lung Lai
Yuan-Lung Lai