1 July 2016 in Journal of Thoracic Oncology
9 September 2015 in PLOS ONE
The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm x 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm x 16 or 0.5 mm x 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner. The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures. Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners.
1 April 2012 in Academic Radiology
1 September 2008 in Journal of Computer Assisted Tomography
To evaluate the performance of 4 methods of measuring the extent of ground-glass opacities as a means of predicting the 5-year relapse-free survival of patients with peripheral nonsmall cell lung cancer (NSLC). Ground-glass opacities on thin-section computed tomographic images of 120 peripheral NSLCs were measured at 7 medical institutions by the length, area, modified length, and vanishing ratio (VR) methods. The performance (Az) of each method in predicting the 5-year relapse-free survival was evaluated using receiver operating characteristic analysis. The mean Az value obtained by the length, area, modified length, and VR methods in the receiver operating characteristic analyses was 0.683, 0.702, 0.728, and 0.784, respectively. The differences between the mean Az value obtained by the VR method and by the other 3 methods were significant. Vanishing ratio method was the most accurate predictor of the 5-year relapse-free survival of patients with peripheral NSLC.
1 September 2012 in British Journal of Radiology
Objectives The objective of this study was to compare the sensitivity of detection of lung nodules on low-dose screening CT images between radiologists and technologists. Methods 11 radiologists and 10 technologists read the low-dose screening CT images of 78 subjects. On images with a slice thickness of 5 mm, there were 60 lung nodules that were ≥5 mm in diameter: 26 nodules with pure ground-glass opacity (GGO), 7 nodules with mixed ground-glass opacity (GGO with a solid component) and 27 solid nodules. On images with a slice thickness of 2 mm, 69 lung nodules were ≥5 mm in diameter: 35 pure GGOs, 7 mixed GGOs and 27 solid nodules. The 21 observers read screening CT images of 5-mm slice thickness at first; then, 6 months later, they read screening CT images of 2-mm slice thickness from the 78 subjects. Results The differences in the mean sensitivities of detection of the pure GGOs, mixed GGOs and solid nodules between radiologists and technologists were not statistically significant, except for the case ...