Ryutaro Kakinuma

Ryutaro Kakinuma

Auto-generated profile, based on publicly available information

Ryutaro Kakinuma

Cancer Screening Division, Research Center for Cancer Prevention and Screening, National Cancer Center, Tokyo, Japan; Cancer Screening Center, National Cancer Center Hospital, Tokyo, Japan; Department of Pulmonology, Tokyo General Hospital, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Journal of Thoracic Oncology
Verified
Journal Article
Closed access
RKRyutaro Kakinuma
Ryutaro Kakinuma
MNMasayuki Noguchi
Masayuki Noguchi
KAKazuto Ashizawa
Kazuto Ashizawa
KKKeiko Kuriyama
Keiko Kuriyama
AMAkiko Miyagi Maeshima
Akiko Miyagi Maeshima
KMKiyoshi Murata
Kiyoshi Murata

9 September 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RKRyutaro Kakinuma
Ryutaro Kakinuma
NMNoriyuki Moriyama
Noriyuki Moriyama
YMYukio Muramatsu
Yukio Muramatsu
SGShiho Gomi
Shiho Gomi
MSMasahiro Suzuki
Masahiro Suzuki
HAHisao Asamura
Hisao Asamura
The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm x 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm x 16 or 0.5 mm x 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner. The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures. Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners.

1 April 2012 in Academic Radiology
Verified
Journal Article
Closed access
RKRyutaro Kakinuma
Ryutaro Kakinuma
KAKazuto Ashizawa
Kazuto Ashizawa
KKKeiko Kuriyama
Keiko Kuriyama
AFAya Fukushima
Aya Fukushima
HIHiroyuki Ishikawa
Hiroyuki Ishikawa
NMNoriyuki Moriyama
Noriyuki Moriyama

1 September 2008 in Journal of Computer Assisted Tomography
Verified
Journal Article
Closed access
RKRyutaro Kakinuma
Ryutaro Kakinuma
KKKen Kodama
Ken Kodama
KYKouzo Yamada
Kouzo Yamada
AYAkira Yokoyama
Akira Yokoyama
SAShuji Adachi
Shuji Adachi
YNYutaka Nishiwaki
Yutaka Nishiwaki
To evaluate the performance of 4 methods of measuring the extent of ground-glass opacities as a means of predicting the 5-year relapse-free survival of patients with peripheral nonsmall cell lung cancer (NSLC). Ground-glass opacities on thin-section computed tomographic images of 120 peripheral NSLCs were measured at 7 medical institutions by the length, area, modified length, and vanishing ratio (VR) methods. The performance (Az) of each method in predicting the 5-year relapse-free survival was evaluated using receiver operating characteristic analysis. The mean Az value obtained by the length, area, modified length, and VR methods in the receiver operating characteristic analyses was 0.683, 0.702, 0.728, and 0.784, respectively. The differences between the mean Az value obtained by the VR method and by the other 3 methods were significant. Vanishing ratio method was the most accurate predictor of the 5-year relapse-free survival of patients with peripheral NSLC.

1 September 2012 in British Journal of Radiology
Verified
Journal Article
Closed access
RKR Kakinuma
R Kakinuma
KAK Ashizawa
K Ashizawa
TKT Kobayashi
T Kobayashi
AFA Fukushima
A Fukushima
HHH Hayashi
H Hayashi
NMN Moriyama
N Moriyama
Objectives The objective of this study was to compare the sensitivity of detection of lung nodules on low-dose screening CT images between radiologists and technologists. Methods 11 radiologists and 10 technologists read the low-dose screening CT images of 78 subjects. On images with a slice thickness of 5 mm, there were 60 lung nodules that were ≥5 mm in diameter: 26 nodules with pure ground-glass opacity (GGO), 7 nodules with mixed ground-glass opacity (GGO with a solid component) and 27 solid nodules. On images with a slice thickness of 2 mm, 69 lung nodules were ≥5 mm in diameter: 35 pure GGOs, 7 mixed GGOs and 27 solid nodules. The 21 observers read screening CT images of 5-mm slice thickness at first; then, 6 months later, they read screening CT images of 2-mm slice thickness from the 78 subjects. Results The differences in the mean sensitivities of detection of the pure GGOs, mixed GGOs and solid nodules between radiologists and technologists were not statistically significant, except for the case ...

1 November 2013 in Chest
Verified
Journal Article
Closed access
PDF file
RKRyutaro Kakinuma
Ryutaro Kakinuma
KAKazuto Ashizawa
Kazuto Ashizawa
YKYoko Kusunoki
Yoko Kusunoki
TKTakeshi Kobayashi
Takeshi Kobayashi
TKTetsuro Kondo
Tetsuro Kondo
YMYuichiro Maruyama
Yuichiro Maruyama