Sai Gopal Vennelaganti

Sai Gopal Vennelaganti

Auto-generated profile, based on publicly available information

Sai Gopal Vennelaganti

Electrical Engineering, Pennsylvania State University, 8082 state college, Pennsylvania United States 16803

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
SVSai Gopal Vennelaganti
Sai Gopal Vennelaganti
Nilanjan Ray ChaudhuriNilanjan Ray Chaudhuri
Nilanjan Ray Chaudhuri
The possibilities of selectively providing inertial and primary frequency support as an emergency support service to asynchronous AC areas through Multiterminal Direct Current (MTDC) grid with minimal-communication are explored. Under nominal condition, only voltage droop is considered to allow the AC systems operate asynchronously as they are meant to. When an AC system needs support, the corresponding converter transmits basic information via a distress signal through the DC lines or existing communication channels used for common DC voltage droop control. Following AC-side disturbances, the frequency droop is activated with values that are predetermined based on our proposed design procedure, which ensures primary frequency support through selective converter participation. Model predictive control, which aims to achieve the best possible frequency dynamics with a single-point actuation is also implemented at the converter station connected to the affected area to provide inertial support. Following a converter outage, MTDC power references are modified to ensure minimal impact on the AC side frequencies. Simulation studies showing the effectiveness of the proposed strategies are presented.

25 June 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
SVSai Gopal Vennelaganti
Sai Gopal Vennelaganti
Nilanjan Ray ChaudhuriNilanjan Ray Chaudhuri
Nilanjan Ray Chaudhuri
Provision of inertial and primary frequency support in a controlled manner through Multiterminal Direct Current (MTDC) grid connecting asynchronous AC areas and offshore wind farms (OWFs) is explored. Under nominal condition, only voltage droop is considered to allow the AC systems operate asynchronously as they are meant to. Following an AC-side disturbance, the corresponding converter transmits basic information via a distress signal through the DC lines or existing communication channels used for common DC voltage-droop control. Upon receiving the distress signal, a new decentralized inertial-droop based controller and the traditional decentralized frequency-droop controller are activated in preselected participating converters with values that are predetermined based on our proposed design procedure. The procedure ensures a new ratio-based performance while providing frequency support. The proposed scheme is based on an Nth-order model of N-asynchronous-area MTDC system. Furthermore, to extract frequency support from an OWF connected to AC-MTDC system, its power reference is modified such that the whole of AC-MTDC system with OWF is emulated as an N-asynchronous-area MTDC system. The proposed strategies are first implemented in the Nth- order model for theoretical validation and later, in full order models of study systems (with and without OWF) for a more rigorous verification.

27 February 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Open access
SVSai Gopal Vennelaganti
Sai Gopal Vennelaganti
Nilanjan Ray ChaudhuriNilanjan Ray Chaudhuri
Nilanjan Ray Chaudhuri
Multiple strategies have been proposed to exchange frequency support amongst asynchronous AC areas through Multiterminal DC (MTDC) grid. Majority of these strategies rely on basic droop control mechanisms involving either inertial or primary frequency droop, or both. This paper addresses the requirements on those droop coefficients, which ensure small-signal stability. To that end, a stability criterion is hypothesized based on certain observations. Using a reduced Nth-order model, the hypothesis is analytically proved for the cases when either inertial droop or primary frequency droop control is active. Moreover, implication of this hypothesis on a recently proposed ratio-based frequency support method is analyzed to derive new stability constraints over and above the existing performance requirements. To support the stability hypothesis, numerically constructed stability boundaries in the droop coefficient space are studied. The stability boundary obtained from small-signal analysis of the full-order nonlinear model is shown to approximately match the boundary obtained from the Nth-order model, which further strengthens the hypothesis. Finally, various time-domain simulation studies are performed on full-order model to validate the stability hypothesis.

27 September 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
SVSai Gopal Vennelaganti
Sai Gopal Vennelaganti
Nilanjan Ray ChaudhuriNilanjan Ray Chaudhuri
Nilanjan Ray Chaudhuri
Coupling between frequency dynamics of AC systems on both inverter and rectifier side of LCC-HVDC with rectifier station operating in frequency control is studied, along with the presence of large DFIG-based wind farms on weak rectifier-side grid. An averaged model with seventy nine states, which includes dynamic models of grids on rectifier and inverter sides, phase-lock-loop, and wind farm is derived. To develop a deeper understanding of the frequency dynamics, a simplified four-state nonlinear model is proposed, which reveals a strong coupling between frequency and AC voltage at HVDC rectifier terminal. A firing angle correction strategy is proposed to decouple frequency-voltage interactions, thereby improving the frequency dynamics on rectifier side. This model is linearized to ascertain the interaction between rectifier and inverter-side frequencies and analytical expression for the frequency dynamics in terms of gains of the frequency controller at rectifier station is derived. The proposed reduced-order model shows the implications of frequency droop control of the wind farms in improving frequency dynamics on both rectifier and inverter sides. Expressions for ‘synchronizing’ and ‘damping torque’ contribution from HVDC and wind farm are also established. The analytical expressions and the effectiveness of the proposed strategies are validated through nonlinear time-domain simulations.

23 April 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
SGSina Gharebaghi
Sina Gharebaghi
SVSai Gopal Vennelaganti
Sai Gopal Vennelaganti
Nilanjan Ray ChaudhuriNilanjan Ray Chaudhuri
Nilanjan Ray Chaudhuri
THTing He
Ting He
TPThomas F. La Porta
Thomas F. La Porta
A challenging problem facing AC-Quasi-Steady-State (AC-QSS) cascading failure models of power system is the divergence issue primarily stemming from voltage collapse phenomena. In reality, there are undervoltage load shedding (UVLS) relays, which aim to prevent such a collapse by shedding a pre-specified fraction of load at buses where the corresponding voltages fall below a threshold. However, capturing the UVLS action in QSS models is very difficult, because most of the time the model cannot generate an equilibrium below the voltage threshold due to divergence. To address this problem, current models have applied different variants of uniform load shedding (ULS) till convergence is achieved, which differ from the ground truth. In order to solve this, we propose a methodology that leverages the post-ULS load flow as a starting point when divergence occurs. In this condition, a sensitivity index coupled with the voltage magnitudes of buses is used to recognize the buses that are most prone to voltage collapse. The UVLS scheme is then applied to these buses. To verify the accuracy of the results, we also present a suitable dynamic cascade model with appropriate limits and protection details that can selectively capture UVLS action, thereby revealing the proximate ground truth. Predictions of the proposed model are validated against those of the dynamic model for representative cases in IEEE 118-bus system. In addition, results of the proposed model are contrasted with two ULS schemes on the 2383-bus Polish system.

26 July 2021
Verified
Conference Paper
Open access
SGSina Gharebaghi
Sina Gharebaghi
SVSai Gopal Vennelaganti
Sai Gopal Vennelaganti
Nilanjan Ray ChaudhuriNilanjan Ray Chaudhuri
Nilanjan Ray Chaudhuri
THTing He
Ting He
TPThomas La Porta
Thomas La Porta
Currently, the divergence problem of AC-Quasi-Steady-State (QSS) cascading failure models is addressed by uniform load shedding (ULS) that trips load in same fraction at all buses till convergence is achieved. However, in reality there exist pre-designed undervoltage load shedding (UVLS) relays that shed load in the subset of buses where voltage descends bellow a threshold, thereby preventing voltage collapse. This might not be captured by ULS, which in turn leads the cascade propagation to a different path. We attack the problem by proposing a new AC-QSS model, which combines voltage magnitude and Q-V sensitivity to predict buses that have undergone UVLS tripping in reality. Moreover, we introduce a centralized AC optimal preventive control approach to alleviate cascade propagation. We use a simple AC-QSS model with ULS as benchmark to contrast results of UVLS model and further demonstrate the effectiveness of preventive control on IEEE 118-bus system and a 2383-bus Polish network.