Sergei P. Nikitin

Sergei P. Nikitin

Auto-generated profile, based on publicly available information

Sergei P. Nikitin

T8 LLC, 44-1 Krasnobogatyrskaya Str., Moscow 107076, Russia

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 1999 in Physical Review E
Verified
Journal Article
Closed access
PDF file
SNS. P. Nikitin
S. P. Nikitin
IAIlya Alexeev
Ilya Alexeev
JFJ. Fan
J. Fan
HMH. M. Milchberg
H. M. Milchberg
We report coupling and guiding of pulses of peak power up to 0.3 TW in 1.5-cm-long preformed plasma waveguides, generated in a high repetition rate argon gas jet. Coupling of up to 52% was measured for 50-mJ, ∼110-fs pulses injected at times longer than 20 ns, giving guided intensities up to ∼5×1016 W/cm2. For short delays between waveguide generation and pulse injection, pulse shortening occurred, with this effect reduced either by increasing delay or injecting a prepulse into the waveguide. There is excessive taper at the waveguide ends, which results from reduced heating at the ends of the jet by the waveguide generation pulse.

25 May 2021 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
EFEdgard Fomiryakov
Edgard Fomiryakov
DKDanil Kharasov
Danil Kharasov
SNSergei Nikitin
Sergei Nikitin
ONOleg Eugenyevich Nanii
Oleg Eugenyevich Nanii
VTVladimir Nikolaevich Treshchikov
Vladimir Nikolaevich Treshchikov
A new technique to measure phase noise properties of highly coherent lasers based on delayed self-heterodyne interferometer (DSHI) is suggested where the Allan variance of the beat note frequency is obtained via digital signal processing and then used to determine laser linewidth and phase noise properties. This method is capable of determining both white frequency noise and flicker-noise contributions and has been used to characterize various types of lasers. A simple numerical model generalizing previous analytical results has been developed and verified. The corresponding requirements imposed on the DSHI optical delay are consistent with numerical modeling results. The measurement results are in agreement with our previous experiments based on direct heterodyning of the same lasers. The technique is particularly suitable for real-time monitoring of the laser phase noise over long periods of time, which is useful for testing and engineering of highly coherent lasers.

1 April 1991 in Quantum Optics: Journal of the European Optical Society Part B
Verified
Journal Article
Closed access
PDF file
SNS P Nikitin
S P Nikitin
AMA V Masalov
A V Masalov

19 June 2018 in Laser Physics
Verified
Journal Article
Closed access
SNS P Nikitin
S P Nikitin
AKA I Kuzmenkov
A I Kuzmenkov
VGV V Gorbulenko
V V Gorbulenko
ONO E Nanii
O E Nanii
VTV N Treshchikov
V N Treshchikov
A novel distributed temperature variation sensor based on a phase-sensitive optical time-domain Rayleigh reflectometer is described and demonstrated experimentally. The measurement technique employs a standard single-mode fiber probe with dual pulses and allows precise tracking of the backscattered signal optical phase variation in time. The phase variation depends on the fiber temperature, with the experimentally measured calibration factor being consistent with that of the theoretical model. The demonstrated technique is capable of providing an operating range of ~50 km with a spatial resolution of ~15 m and offers a simple alternative to distributed temperature sensors based on Raman and Brillouin scattering.

1 December 1997 in Optics Letters
Verified
Journal Article
Closed access
PDF file
SNS. P. Nikitin
S. P. Nikitin
TAT. M. Antonsen
T. M. Antonsen
TCT. R. Clark
T. R. Clark
YLYuelin Li
Yuelin Li
HMH. M. Milchberg
H. M. Milchberg
We report guiding of sub-100-fs pulses at intensities up to 5×1015 W/cm2 over a distance of 1 cm in a preformed plasma channel. The width of the guided pulse was shortened, which we attribute to ionization-induced refraction at the channel entrance. A pulse energy throughput of 30% in the lowest-order was measured.

1 August 2008 in Applied Spectroscopy
Verified
Journal Article
Closed access
GCGelu Comanescu
Gelu Comanescu
CMCharles K. Manka
Charles K. Manka
JGJacob Grun
Jacob Grun
SNSergei Nikitin
Sergei Nikitin
DZDaniel Zabetakis
Daniel Zabetakis
The first two-dimensional (2D) resonance Raman spectra of TNT, RDX, HMX, and PETN are measured with an instrument that sequentially and rapidly switches between laser wavelengths, illuminating these explosives with forty wavelengths between 210 nm and 280 nm. Two-dimensional spectra reflect variations in resonance Raman scatter with illumination wavelength, adding information not available from single or few one-dimensional spectra, thereby increasing the number of variables available for use in identification, which is especially useful in environments with contaminants and interferents. We have recently shown that 2D resonance Raman spectra can identify bacteria. Thus, a single device that identifies the presence of explosives, bacteria, and other chemicals in complex backgrounds may be feasible.