9 May 2025 in IEEE Transactions on Power Delivery
Current decoupling control for LCL-type threephase energy storage converters under weak grid conditions faces challenges including multiple control variables, complex decoupling processes, and poor stability. To achieve costeffective and highly stable current decoupling, this study proposes a grid-impedance-embedded higher-order Linear Active Disturbance Rejection Control (EGI-LADRC) method. The approach treats three internal coupling terms in the current control loop as disturbances and implements sensorminimized current decoupling by constructing a third-order controller to eliminate these disturbances. In the design of the Linear Extended State Observer (LESO), a compensation factor b0 incorporating grid impedance information is introduced, enabling the observer to rapidly estimate and mitigate adverse grid impedance effects on output current under varying grid conditions, thereby enhancing system stability. Through impedance modeling and stability analysis, parameter design guidelines for the proposed EGI-LADRC are established, along with comparative stability evaluations against other algorithms under diverse operating scenarios. Experimental validation on a 4kW prototype confirms that the converter achieves low-distortion current output under large grid impedances using only two sensor sets, significantly outperforming PI-based and conventional LADRC-based methods.
16 March 2026 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Under weak grid conditions, variations in the equivalent grid impedance adversely affect both the current control loop performance and the dq-axis current coupling exacerbated by the grid impedance in LCL filtered energy storage converters, thereby limiting their stability, dynamic response, and output current quality. To address this issue, this study proposes a grid-impedance-estimation-based linear active disturbance rejection control strategy (GIE-LADRC). This method integrates the online estimated grid impedance into the design of the LADRC compensation factor, enabling the factor to better approximate the actual system gain under impedance variations in weak grids. This enhances the ability of the Linear Extended State Observer (LESO) to observe and suppress disturbances caused by impedance. In practice, LADRC first provides approximate decoupled control of the dq-axis currents. Subsequently, under this decoupled condition, a reactive power variation strategy that maintains a constant d-axis current reference is employed to obtain an online estimate of the equivalent grid impedance, which has minimal impact on the converter's active current output during the estimation process. The stability of the proposed method under the complete current control framework is evaluated through impedance model-based stability analysis. Finally, experimental results from a 4 kW prototype confirm that GIE-LADRC can maintain high-quality current output even in very weak grids with a SCR below 2.