Purpose: To study the effects of Ologen collagen matrix on the outcomes of the Ahmed glaucoma valve implant. Study Design: Retrospective case-control multicenter study, conducted at four centers, comparing the 6-month outcomes of Ahmed valve implants with or without Ologen. Participants: The study included 125 eyes in a 4:1 pairing (25 patients with Ologen matched to 100 patients without Ologen). Intervention: Ologen was placed over the Ahmed plate in the study group. Success was defined as an intraocular pressure (IOP) ≤ 21 mmHg either with no medication (complete success) or regardless of medications (qualified success). Other outcomes included IOP variation, eye drop use, and surgical complications. Results: Overall, the IOP decreased from 30.72 ± 9.08 to 16.14 ± 4.79 mmHg (p=0.0001). Of the 125 eyes, 26 achieved complete success and 94 achieved qualified success. There was no difference in complete success between the groups (p=0.12); however, there was a difference in qualified success (p=0.01), with better results in the no-Ologen group (80% vs 56%). There were no differences in the decrease in medications (p=0.06), as well as the incidence of complications (p=0.69). Although the need for postoperative surgical reintervention was higher in the no-Ologen group (13% vs 4%), the difference was not significant (p=0.2). Conclusion: The reductions in IOP and number of medications were similar in both groups after 6 months, with similar complication rates. The qualified success rate was lower in the Ologen group, but further studies are needed to clarify the role of Ologen in Ahmed valve implants.
3 December 2025 in Revista Brasileira de Oftalmologia
RESUMO Objetivo: Avaliar o conhecimento e o hábito da população brasileira acerca do glaucoma. Métodos: Realizou-se um estudo transversal com amostra aleatória e calculada para ser representativa da população brasileira. A coleta dos dados foi feita por empresa especializada em levantamentos populacionais, por meio de contato telefônico, com equipe treinada. Utilizou-se um questionário estruturado com perguntas sobre glaucoma, envolvendo conceito, fatores de risco e tratamento, bem como os hábitos e atitudes de prevenção em saúde ocular. Todas as entrevistas foram [...] RESUMO Objetivo: Avaliar o conhecimento e o hábito da população brasileira acerca do glaucoma. Métodos: Realizou-se um estudo transversal com amostra aleatória e calculada para ser representativa da população brasileira. A coleta dos dados foi feita por empresa especializada em levantamentos populacionais, por meio de contato telefônico, com equipe treinada. Utilizou-se um questionário estruturado com perguntas sobre glaucoma, envolvendo conceito, fatores de risco e tratamento, bem como os hábitos e atitudes de prevenção em saúde ocular. Todas as entrevistas foram
Objective: To evaluate the feasibility, accuracy, and correlation of intraocular pressure (IOP) measurements obtained with the TD-8000 ® rebound tonometer compared with Perkins ® applanation tonometry in children with glaucoma or suspected glaucoma. Methods: This prospective diagnostic accuracy study included 78 eyes of 44 children under 8 years. IOP was measured using the TD-8000 ® during outpatient visits and under general anesthesia. Perkins ® tonometry was performed under general anesthesia. Diagnostic performance was calculated using a 21 mmHg cutoff. Agreement was evaluated using correlation and Bland–Altman methods. Results: Rebound tonometry was feasible in 89% of awake children. Under general anesthesia, TD-8000 ® overestimated IOP compared with Perkins ® , with a mean difference of 9.06 mmHg (SE = 0.62; p < 0.001). Accuracy was 87.5%, sensitivity 22.2%, specificity 98.2%, negative predictive value 88.5% and positive predictive value 66.7%. Outpatient rebound IOP measurements correlated weakly with applanation under general anesthesia (R = 0.32; p = 0.04). Conclusions: The TD-8000 ® is a feasible but less accurate tool for IOP measurement in young children. Weak correlation between outpatient rebound tonometry and applanation under general anesthesia limits its reliability, although high specificity may offer clinical value in high-prevalence settings.
1 January 2026 in Arquivos Brasileiros de Oftalmologia
Purpose: To compare the efficacy and safety of trabeculectomy with mitomycin C, performed with versus without adjunctive Ologen collagen matrix in a multicenter real-world setting. Methods: This multicenter retrospective comparative study included 277 patients (365 eyes) who underwent trabeculectomy with mitomycin C, with or without Ologen, between 2017 and 2022 across five Brazilian centers. Extracted data comprised demographic characteristics, glaucoma subtype, intraocular pressure, number of glaucoma medications, postoperative interventions, complications, and additional surgical procedures. Surgical success was defined using two criteria: (1) intraocular pressure ≤21mmHg with ≥20% reduction from baseline and (2) final intraocular pressure between 6 and 21mmHg. Outcomes were categorized as complete (without medications) or qualified (with medications). Results: Both groups achieved substantial reductions in intraocular pressure and medication burden at 12 months, with high rates of complete and qualified success under both definitions. The Ologen group required fewer suture lysis procedures (49.0% vs. 60.8%; p=0.025), suggesting a modulatory effect on early postoperative fibrosis. Rates of other postoperative interventions, complications, and additional glaucoma surgeries were comparable between groups. Kaplan–Meier analysis demonstrated no significant difference in cumulative success over time. Conclusion: Trabeculectomy with mitomycin C is effective and safe regardless of adjunctive Ologen use. Although Ologen did not confer superior long-term efficacy, its association with reduced suture lysis suggests a potential role in modulating early wound healing.
2 February 2022 in Revista Brasileira de Oftalmologia
Minimally invasive glaucoma surgeries are surgical treatment alternatives for glaucoma aimed at reducing intraocular pressure with a better safety profile compared to traditional trabeculectomy. However, in spite of less invasive techniques, complications may develop in any surgical procedure. To the best of our knowledge, this is the first case report of anterior uveitis following combined treatment with cataract surgery and iStent inject® which addresses the management of postoperative inflammation. Postoperative anterior uveitis in a patient submitted to combined treatment [...] ABSTRACT Minimally invasive glaucoma surgeries are surgical treatment alternatives for glaucoma aimed at reducing intraocular pressure with a better safety profile compared to traditional trabeculectomy. However, in spite of less invasive techniques, complications may develop in any surgical procedure. To the best of our knowledge, this is the first case report of anterior uveitis following combined treatment with cataract surgery and iStent inject® which addresses the management of postoperative inflammation. Postoperative anterior uveitis in a patient submitted to combined treatment